Optimal rule-based energy management and sizing of a grid-connected renewable energy microgrid with hybrid storage using Levy Flight Algorithm

被引:3
作者
Modu, Babangida [1 ,3 ]
Abdullah, Md Pauzi [1 ,2 ]
Alkassem, Abdulrahman [4 ]
Hamza, Mukhtar Fatihu [5 ]
机构
[1] Univ Teknol Malaysia, Fac Elect Engn, Ctr Elect Energy Syst, UTM, Skudai 81310, Johor, Malaysia
[2] Univ Teknol Malaysia, Inst Future Energy, UTM, Skudai 81310, Johor, Malaysia
[3] Univ Maiduguri, Dept Elect & Elect Engn, Maiduguri 1069, Nigeria
[4] Islamic Univ Madinah, Fac Engn, Dept Elect Engn, Madinah 42351, Saudi Arabia
[5] Prince Sattam Bin Abdulaziz Univ, Coll Engn Alkharj, Dept Mech Engn, Alkharj 11942, Saudi Arabia
来源
ENERGY NEXUS | 2024年 / 16卷
关键词
Microgrid; Hydrogen storage; Electrolyzer; Fuel cell; Optimization; HYDROGEN-PRODUCTION; TECHNOECONOMIC ASSESSMENT; SWARM ALGORITHM; SYSTEM; OPTIMIZATION; GENERATION; DESIGN;
D O I
10.1016/j.nexus.2024.100333
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The study addresses the integration of hybrid hydrogen (H2) and battery (BT) energy storage systems into a renewable energy microgrid comprising solar photovoltaic (PV) and wind turbine (WT) systems. The research problem focuses on improving the effectiveness and computational efficiency of energy management systems (EMS) while ensuring high system reliability. Despite the existing optimization methods for hybrid microgrids, challenges remain in optimizing energy storage and capacity planning in grid-connected microgrids. To solve this, we propose the use of the Levy Flight Algorithm (LFA) to optimize the capacities of PV, WT, H 2 tanks, electrolyzers (EL), fuel cells (FC), and BT, which presents a complex nonlinear optimization challenge. The novelty of this study lies in integrating the LFA with a rule-based EMS, enhancing system reliability and efficiency. The proposed approach significantly reduces the annualized system cost (ASC) and the levelized cost of energy (LCOE). The result demonstrate that the LFA outperforms methods like the Salp Swarm Algorithm (SSA), Particle Swarm Optimization (PSO), Grey Wolf Optimization (GWO) and Genetic Algorithm (GA), yielding cost savings of $3,309, $5,297, $4,484, and $5,129 respectively. The LFA achieves the lowest LCOE at $0.275/kWh, compared to $0.278/kWh with SSA, $0.289/kWh with GA, $0.280/kWh with PSO and $0.283/kWh with GWO. This research contributes to the broader scientific community by providing a more efficient approach to optimizing renewable energy microgrids with hybrid storage systems, thus promoting eco-friendly and cost-effective energy solutions. The proposed system design offers a pathway to future energy systems with high renewable integration, especially as technology advances and costs continue to decrease.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Energy Management Strategy and Optimal Sizing for Hybrid Energy Storage Systems Using an Evolutionary Algorithm
    Wang, Li
    Li, Mince
    Wang, Yujie
    Chen, Zonghai
    IEEE TRANSACTIONS ON INTELLIGENT TRANSPORTATION SYSTEMS, 2022, 23 (09) : 14283 - 14293
  • [32] A Grid-Connected Microgrid Model and Optimal Scheduling Strategy Based on Hybrid Energy Storage System and Demand-Side Response
    Jing, Yaqian
    Wang, Honglei
    Hu, Yujie
    Li, Chengjiang
    ENERGIES, 2022, 15 (03)
  • [33] A Rule-Based Bionic Energy Management System for Grid-Connected Community Microgrid Using Peer-to-Peer Trading With Rapid Settlement
    Liu, Bin
    Wang, Dan
    Zhu, Jinli
    Gu, Bo
    Mao, Chengxiong
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2024, 15 (01) : 215 - 235
  • [34] Multi-Objective Stochastic Optimal Operation of a Grid-Connected Microgrid Considering an Energy Storage System
    Fan, Hong
    Yuan, Qianqian
    Cheng, Haozhong
    APPLIED SCIENCES-BASEL, 2018, 8 (12):
  • [35] Comparative study of hydrogen storage and battery storage in grid connected photovoltaic system: Storage sizing and rule-based operation
    Zhang, Yang
    Campana, Pietro Elia
    Lundblad, Anders
    Yan, Jinyue
    APPLIED ENERGY, 2017, 201 : 397 - 411
  • [36] Optimal Energy for Grid-Connected Microgrid with Battery Swapping Station and Wind Photovoltaic and Energy Storage
    Song, Jiaoru
    Suo, Lian
    PROCEEDINGS OF 2019 IEEE 3RD INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC), 2019, : 1469 - 1473
  • [37] Real-Time Implementation & Evaluation of Grid-Connected Microgrid Energy Management Systems
    Rangel, Carlos Mauricio
    Mascarella, Diego
    Joos, Geza
    2016 IEEE ELECTRICAL POWER AND ENERGY CONFERENCE (EPEC), 2016,
  • [38] Optimal Sizing of PV, Wind based Grid Connected Hybrid Renewable Energy Systems for Rural Areas in Presence of EVs
    Parida, Bikash Kumar
    Bohre, Aashish Kumar
    2022 INTERNATIONAL CONFERENCE ON DECISION AID SCIENCES AND APPLICATIONS (DASA), 2022, : 1311 - 1316
  • [39] Management of charging cycles for grid-connected energy storage batteries
    Al Essa, Mohammed Jasim M.
    JOURNAL OF ENERGY STORAGE, 2018, 18 : 380 - 388
  • [40] DETERMINATION OF OPTIMAL SIZING MODEL FOR BATTERY ENERGY STORAGE SYSTEM IN GRID CONNECTED MICROGRID
    Shah, Prakruti
    Mehta, Bhinal
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2020, 15 (02): : 778 - 791