Three-dimensional zone of the centers of resistance of the mandibular incisors and canines: A novel approach by finite element analysis

被引:0
|
作者
Yang, Yangyang [1 ,4 ]
Pan, Shengxuan [1 ,2 ,3 ]
Zhao, Jie [1 ,4 ]
Pan, Xiaogang [2 ,3 ]
Tsai, Tsung-Yuan [1 ,4 ]
机构
[1] Shanghai Jiao Tong Univ, Med X Res Inst, Sch Biomed Engn, Shanghai 200030, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Coll Stomatol, Natl Clin Res Ctr Oral Dis,Dept Orthodont,Sch Med, Shanghai 200011, Peoples R China
[3] Shanghai Res Inst Stomatol, Shanghai 200011, Peoples R China
[4] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, Dept Orthoped, Shanghai 200011, Peoples R China
关键词
Orthodontics; Mandibular incisors; Mandibular canines; Tooth movement; Finite element analysis; Biomechanics; TOOTH MOVEMENT; ORTHODONTIC TREATMENT; DISPLACEMENT; INVISALIGN; TEETH;
D O I
10.1016/j.ortho.2024.100933
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives > The distribution and size of the zone of the centres of resistance (ZCR) are critical for accurate orthodontic treatments and minimizing unexpected tooth movements. However, this information remains unclear for mandibular incisors and canines. This study aims to address these gaps in knowledge. Methods > Finite element models of four incisors and canines from four individuals were created. Four centres of resistance (CRs) under four orthodontic directions (0 degrees similar to 45 degrees similar to 90 degrees similar to 135 degrees to the sagittal plane in the horizontal plane) were assessed by a novel method. The height of the CRs was normalized to a percentage of the long axis, and the offsets were expressed as a distance value after normalization. The ZCR was obtained by fitting a 90% confidence sphere of the CR distribution. Validation was conducted to find the perturbations when the positions out of the zone were applied. Results > The maximum variation of CR in the heights under four directions was 5.17% and 3.70% for the incisors and canines, respectively. The maximum offset between the CR and long axis was 0.14 mm in incisors and 0.99 mm in canines. The height of the zone in the incisor and canine was 57.75% and 59.72%, and the radius of the zone was 0.60 mm and 0.65 mm, respectively. The force-acting point outside the zone produced a large rotation, which was unexpected. Conclusions > The ZCR of mandibular incisors located slightly lower than that of canines, but they were almost the same size. The ZCR was recommended as the "gold reference" for orthodontics to reduce unexpected movement.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Three-dimensional finite element analysis of residual stress in arteries
    Raghavan, ML
    Trivedi, S
    Nagaraj, A
    McPherson, DD
    Chandran, KB
    ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (02) : 257 - 263
  • [12] Three-Dimensional Finite Element Analysis of Different Plating Techniques for Unfavorable Mandibular Angle Fractures
    Ayali, Aysa
    Erkmen, Erkan
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (03) : 603 - 607
  • [13] Effects of the advanced mandibular spring on mandibular retrognathia treatment: a three-dimensional finite element study
    Cheng Zhu
    Ruomei Li
    Lingjun Yuan
    Yikan Zheng
    Yu Jin
    Hairui Li
    Chao Liu
    Lunguo Xia
    Bing Fang
    BMC Oral Health, 22
  • [14] Effects of the advanced mandibular spring on mandibular retrognathia treatment: a three-dimensional finite element study
    Zhu, Cheng
    Li, Ruomei
    Yuan, Lingjun
    Zheng, Yikan
    Jin, Yu
    Li, Hairui
    Liu, Chao
    Xia, Lunguo
    Fang, Bing
    BMC ORAL HEALTH, 2022, 22 (01)
  • [15] Three-Dimensional Force Characterizations in Maxillary Molar Distalization: A Finite Element Study
    Wang, Jianing
    Tsolaki, Anastasia
    Voudouris, John C.
    Premaraj, Thyagaseely Sheela
    Premaraj, Sundaralingam
    Gu, Linxia
    Dong, Pengfei
    APPLIED SCIENCES-BASEL, 2023, 13 (12):
  • [16] Three-Dimensional Finite Element Analysis of Steel Silo
    Chen, Changbing
    Liang, Xingpei
    Bi, Shouyi
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 4031 - +
  • [17] Three-dimensional finite element analysis of subdural hematoma
    Huang, HM
    Lee, MC
    Chiu, WT
    Chen, CT
    Lee, SY
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1999, 47 (03): : 538 - 544
  • [18] Three-dimensional finite element analysis of optimal distribution model of vertebroplasty
    Wang, Deguo
    Li, Yang
    Yin, Honglin
    Li, Jun
    Qu, Jiao
    Jiang, Minbo
    Tian, Jiwei
    ANNALS OF PALLIATIVE MEDICINE, 2020, 9 (03) : 1062 - 1072
  • [19] Three-Dimensional Modelling and Finite Element Analysis of an Ankle External Fixator
    Ramlee, Muhammad Hanif
    Kadir, Mohammed Rafiq Abdul
    Harun, Habibollah
    MATERIALS, INDUSTRIAL, AND MANUFACTURING ENGINEERING RESEARCH ADVANCES 1.1, 2014, 845 : 183 - 188
  • [20] A three-dimensional finite element analysis of permanent maxillary central incisors in different stages of root development and trauma settings
    Dezzen-Gomide, Ana Claudia
    Carvalho, Marco Aurelio de
    Lazari-Carvalho, Priscilla Cardoso
    Oliveira, Helder Fernandes de
    Cury, Altair A. Del Bel
    Yamamoto-Silva, Fernanda Paula
    Silva, Brunno Santos de Freitas
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 207