Validation of the European visual field standards for driving: A driving simulator-based study

被引:0
作者
Sudmann, Thea Melsen [1 ,2 ]
Torblaa, Anna [3 ,4 ]
Austeng, Dordi [4 ,5 ]
Reshodko, Irina [6 ,7 ]
Rehm, Johannes [7 ,8 ]
Bro, Tomas [9 ]
Braekhus, Anne [10 ,11 ]
Klungsoyr, Ole [2 ,12 ]
Rowe, Fiona [13 ]
Jorstad, oystein Kalsnes [1 ,2 ]
机构
[1] Oslo Univ Hosp, Dept Ophthalmol, Postboks 4950 Nydalen, N-0424 Oslo, Norway
[2] Univ Oslo, Inst Clin Med, Fac Med, Oslo, Norway
[3] Drammen Hosp, Dept Ophthalmol, Drammen, Norway
[4] Univ Trondheim Hosp, St Olavs Hosp, Dept Ophthalmol, Trondheim, Norway
[5] Norwegian Univ Sci & Technol, Dept Neuromed & Movement Sci, Trondheim, Norway
[6] Huq Ind, London, England
[7] Way AS, Trondheim, Norway
[8] Norwegian Univ Sci & Technol, Trondheim, Norway
[9] Linkoping Univ, Dept Biomed & Clin Sci, Linkoping, Sweden
[10] Oslo Univ Hosp, Norwegian Natl Ctr Ageing & Hlth, Dept Neurol, Oslo, Norway
[11] Oslo Univ Hosp, Dept Geriatr Med, Memory Clin, Oslo, Norway
[12] Oslo Univ Hosp, Ctr Forens Psychiat, Div Mental Hlth & Addict, Oslo, Norway
[13] Univ Liverpool, Inst Populat Hlth, Liverpool, England
关键词
drivers licence; driving ability; driving simulator; perimetry; visual field;
D O I
10.1111/aos.16783
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo determine whether we could establish evidence-based pass/fail criteria for perimetry in the context of the European visual field standards for driving.MethodsThis two-centre, cross-sectional study included participants with binocular visual field loss that had led to revocation of a group-1 driving licence. The participants underwent cognitive and binocular visual testing, including the European Driving Test (EDT), a perimetry algorithm that adheres to the European visual field standards. We used a high-fidelity driving simulator to compare the driving ability of these participants with healthy controls. Two driving instructors classified each driving test as passed or failed. Receiver operating characteristic (ROC) analysis and area under the curve (AUC) determined the ability of perimetry to discriminate between passed and failed driving tests.ResultsThe study included 70 participants with visual field loss and 37 controls. A non-significantly higher proportion of controls passed the driving test (75% vs. 63%; p = 0.22). In ROC analysis, contrast sensitivity performed best (AUC of 0.73), followed by NEI VFQ-25 (AUC of 0.64). Peripheral visual field (AUC of 0.56) and central visual field (AUC of 0.47) performed weaker. Combining the central and peripheral visual field, and their interaction, increased AUC to 0.63.ConclusionPerimetry was a poor predictor of simulator-based driving test result, and we could not establish appropriate pass/fail criteria for the European visual field standards. Because perimetry is not an accurate diagnostic tool for fitness to drive, a practical driving assessment should be performed in case of doubt.
引用
收藏
页码:222 / 231
页数:10
相关论文
共 23 条
[1]  
[Anonymous], 1996, Transportation Research Record: Journal of the Transportation Research Board, DOI [DOI 10.1177/0361198196155000105, DOI 10.3141/1550-05]
[2]   The effects of visual field loss from glaucoma on performance in a driving simulator [J].
Bro, Tomas ;
Andersson, Jan .
ACTA OPHTHALMOLOGICA, 2022, 100 (02) :218-224
[3]   Strain out a gnat and swallow a camel? - vision and driving in the Nordic countries [J].
Bro, Tomas ;
Lindblom, Bertil .
ACTA OPHTHALMOLOGICA, 2018, 96 (06) :623-630
[4]   An evaluation of the Mars Letter Contrast Sensitivity Test [J].
Dougherty, BE ;
Flom, RE ;
Bullimore, MA .
OPTOMETRY AND VISION SCIENCE, 2005, 82 (11) :970-975
[5]  
eur-lex, 2009, OFFICIAL J EUROPEAN
[6]  
Eyesight Working Group, 2005, NEW STANDARDS VISUAL
[7]   Predictive Value of the Esterman Visual Field Test on the Outcome of the On-Road Driving Test [J].
Faraji, Yasmin ;
Tan-Burghouwt, Marian T. ;
Bredewoud, Ruud A. ;
van Nispen, Ruthm. A. ;
Van Rijn, Laurentius J. .
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (03)
[8]   Driving and exceptional cases: Supporting relicensing evaluation in patients whose visual fields fail to meet standards [J].
Harper, Robert A. ;
Parkes, Jeremy A. ;
Dickinson, Christine M. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2022, 42 (05) :1009-1014
[9]   A traffic perimetry test that adheres to the European visual field requirements [J].
Jorstad, Oystein Kalsnes ;
Jonsdottir, Thora Elisabet ;
Zysset, Stefan ;
Rowe, Fiona .
ACTA OPHTHALMOLOGICA, 2021, 99 (04) :E555-E561
[10]   Receiver Operating Characteristic Curve in Diagnostic Test Assessment [J].
Mandrekar, Jayawant N. .
JOURNAL OF THORACIC ONCOLOGY, 2010, 5 (09) :1315-1316