OVERALL THERMAL TRANSFER ANALYSIS OF GLAZING FACADE DESIGN FOR PASSIVE BUILDING ENERGY EFFICIENCY

被引:1
作者
Vighio, Anees Ahmed [1 ]
Zakaria, Rozana [1 ]
Ahmad, Faridahanim [1 ]
Munikanan, Vikneswaran [2 ]
Wahi, Noraziah [3 ]
Aminuddin, Eeydzah [4 ]
Wen, Thong Jia [1 ]
Saha, Kamaliah Mohd [1 ]
Umran, Nur Izyan Liyana [1 ]
Pawlowicv, Joanna A. [5 ]
机构
[1] Univ Teknol Malaysia, Fac Civil Engn, Skudai 81310, Johor Bahru, Malaysia
[2] Univ Pertahanan Nas Malaysia, Dept Civil Engn, Kuala Lumpur, Malaysia
[3] Univ Teknol MARA UiTM, Fac Planning Surveying & Architecture, Sarawak, Malaysia
[4] Univ Teknol MARA, Coll Engn, Sch Civil Engn, Shah Alam, Selangor, Malaysia
[5] Univ Warmia & Mazury, Fac Geodesy Geospatial & Civil Engn, Olsztyn, Poland
关键词
glazing facade; passive design; overall thermal transfer value; energy efficiency; building; CLIMATE;
D O I
10.59440/ceer/193131
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The global warming incremental impacts such as temperature, precipitation, rise in sea level, and extreme weather events are indeed being observed globally. In recent decades, energy demand and greenhouse gas emissions have increased due to buildings being designed with active cooling and heating solutions, despite global attempts to reduce energy consumption. About 50 percent of all energy use is attributed to buildings. There has been a debate for Decades on building active and passive design, but very limited studies have been carried out to confirm the Overall Thermal Transfer Value (OTTV) during the operation phase of the building. This paper highlights the analysis of OTTV in the Passive Design Strategies using several conditions of glazing facades. The passive design of glazing facade strategies includes the variation in opaque wall Colour with different values of the coefficient of solar absorption, change in glazing type (U-Value and Shading Coefficient), and the decrease in the size of the openings. Building parameters were collected and OTTV was determined using the equation in Malaysian Standard MS 1525 for Energy Efficiency. The OTTV was then compared to the recommended value for Malaysia's tropical climate. Results showed that different paint Colours improved OTTV by up to 23.05%, changing glazing type reduced OTTV from 76.93 W/m2 (Base case) to 64.12 W/m2 (Double Low-E, e2=.1 Tint green), and reducing glass area by 10% lowered OTTV to 62.24 W/m2.Whereas, by combining the Type of Glazing and White facade Colour the OTTV was reduced to 39.68%. It is concluded that this OTTV analysis enhances building energy efficiency and reduces cooling loads.
引用
收藏
页码:503 / 520
页数:18
相关论文
共 34 条
[1]   Development of a Model for OTTV and RTTV based on BIM-VPL to Optimize the Envelope Thermal Performance [J].
Abass, F. ;
Ismail, L. H. ;
Wahab, I. A. ;
Elgadi, A. A. .
2ND GLOBAL CONGRESS ON CONSTRUCTION, MATERIAL AND STRUCTURAL ENGINEERING, 2020, 713
[2]   Energy-Efficient Retrofitting Strategies for Residential Buildings in hot climate of Oman [J].
Al-Saadi, Saleh N. J. ;
Al-Hajri, Jawaher ;
Sayari, Mohamed A. .
PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 :2009-2014
[3]  
[Anonymous], 2009, The Development of Green Building Index Malaysia, P14
[4]  
[Anonymous], 2018, Malaysia Energy Statistics Handbook
[5]  
[Anonymous], 2014, Department of Statistics in Malaysia
[6]   Comparative Study of Thermal Surface Analysis on High-Rise Apartment Facades with Colonial and Neo-Minimalist Style Design in Penang, Malaysia [J].
Arab, Yasser ;
Hassan, Ahmad Sanusi ;
Qanaa, Bushra .
ADVANCED SCIENCE LETTERS, 2017, 23 (07) :6148-6152
[7]  
ASHRAE, 2010, Energy Standard for Buildings Except Low-Rise Residential Buildings
[8]   Impact of Passive Energy Efficiency Measures on Cooling Energy Demand in an Architectural Campus Building in Karachi, Pakistan [J].
Bughio, Mushk ;
Khan, Muhammad Shoaib ;
Mahar, Waqas Ahmed ;
Schuetze, Thorsten .
SUSTAINABILITY, 2021, 13 (13)
[9]   Investigating the thermal performance and Overall Thermal Transfer Value (OTTV) of air-conditioned buildings under the effect of adjacent shading against solar radiation [J].
Chan, Lok Shun .
JOURNAL OF BUILDING ENGINEERING, 2021, 44
[10]   Controlling building energy use by Overall Thermal Transfer Value (OTTV) [J].
Chow, WK ;
Yu, PCH .
ENERGY, 2000, 25 (05) :463-478