An Efficient Fluorescent Chemosensing Probe for Total Determination and Speciation of Ultra-Trace Levels of Mercury (II) Species in Water

被引:0
|
作者
Alwael, H. [1 ]
Alzahrani, K. A. [1 ,2 ]
Abduljabbar, T. N. [1 ]
Alharthi, A. S. [1 ,3 ]
Alshareef, F. M. [1 ]
Bahaidarah, E. A. [1 ]
Alkhraije, A. A. [1 ,4 ]
El-Shahawi, M. S. [1 ,5 ]
机构
[1] King Abdulaziz Univ, Fac Sci, Dept Chem, POB 80203, Jeddah 21589, Saudi Arabia
[2] King Abdulaziz Univ, Ctr Excellence Adv Mat Res CEAMR, Jeddah 21589, Saudi Arabia
[3] Umm Al Qura Univ, Fac Sci Appl, Dept Chem, Mecca, Saudi Arabia
[4] Umm AL Qura Univ, Al Leith Univ Coll, Dept Chem, Mecca, Al Leith, Saudi Arabia
[5] Damietta Univ, Fac Sci, Dept Chem, Dumyat, Egypt
关键词
Chemical equilibria; Extractive spectrofluorimetry; mercury (ii) determination and speciation; Rose Bengal; Ternary complex ion associate; AQUEOUS-SOLUTIONS; PRECONCENTRATION; EXTRACTION; SPECTROMETRY; ENHANCEMENT; REMOVAL; FISH;
D O I
10.1007/s10895-024-03999-w
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The current study reports a novel fluorescent chemosensor based on the tagging agent 4,5,6,7-tetrachloro-2',4',5',7'-tetraiodofluorescein (Rose Bengal, RB) for detection of trace levels of Hg2+in environmental water. The established probe has been based upon liquid-liquid extraction (LLE) of the developed ternary complex ion associate {[Hg (bpy)2]2+.[RB]2-} of Hg2+ -2,2- bipyridyl complex [Hg (bpy)2]2+ and RB at pH 9.0 onto chloroform and measuring the resulting fluorescence enhancement signal intensity at lambda ex/em = 570/ (580-600) nm. The limits of detection (LOD) and quantification (LOQ) of for Hg2+ was calculated to be 6.06 and 20 nM with a linear dynamic range (LDR) of 0.02-20 mu M, respectively. The stability constant, stoichiometry, chemical equilibria, and the thermodynamic parameters (Delta H, Delta S, and Delta G) of the developed ion associate were evaluated and assigned. Student's t and F tests at 95% confidence were fruitfully used for validation of the proposed methodology for Hg2+ detection in water samples with the aid of inductively coupled plasma-optical emission spectrometry (ICP-OES). The established strategy was successfully applied for detection of trace levels of Hg2+ in water samples with acceptable results. The proposed probe was satisfactorily applied for total determination and speciation of Hg in various water samples. Integrating the functional chelating agent onto associate formation to improve the selectivity and sensing properties of the LLE combining sensing probe towards target analyte in water represent the main interest.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A novel carbonothioate-based benzothiazole fluorescent probe for trace detection of mercury (II) in real water samples
    Tian, Qing-Qin
    Zhao, Zhi-Gang
    Shi, Zhi-Chuan
    INORGANICA CHIMICA ACTA, 2021, 521
  • [22] Ultra-trace detection and efficient adsorption removal of multiple water-soluble volatile organic compounds by fluorescent sensor array
    Che, Huachao
    Yan, Shulin
    Xiong, Ming
    Nie, Yulun
    Tian, Xike
    Li, Yong
    JOURNAL OF HAZARDOUS MATERIALS, 2023, 443
  • [23] Systematic Errors in the Determination of Trace Metals, Part II. Memory Effects of Quartz Vessels Used for Sample Preparation in the Determination of Ultra-Trace Levels of Platinum
    Joanna Kowalska
    Monika Asztemborska
    Beata Godlewska-Żyłkiewicz
    Jerzy Golimowski
    Microchimica Acta, 2005, 150 : 55 - 58
  • [24] Systematic errors in the determination of trace metals, Part II. Memory effects of quartz vessels used for sample preparation in the determination of ultra-trace levels of platinum
    Kowalska, J
    Asztemborska, M
    Godlewska-Zylkiewicz, B
    Golimowski, J
    MICROCHIMICA ACTA, 2005, 150 (01) : 55 - 58
  • [25] Determination of ultra-trace levels of palladium in water samples by cloud point extraction and graphite furnace atomic absorption spectrometry
    Han, Quan
    Huo, Yanyan
    Yang, Xiaohui
    Yao, Xing
    JOURNAL OF CHEMICAL RESEARCH, 2021, 45 (9-10) : 883 - 889
  • [26] A Preconcentration Procedure for Determination of Ultra-Trace Mercury (II) in Environmental Samples Employing Continuous-Flow Cold Vapor Atomic Absorption Spectrometry
    Laleh Adlnasab
    Homeira Ebrahimzadeh
    Ali Akbar Asgharinezhad
    Mahnaz Nasiri Aghdam
    Ali Dehghani
    Sousan Esmaeilpour
    Food Analytical Methods, 2014, 7 : 616 - 628
  • [27] Determination of Ultra-trace Mercury(II) by Flow-injection/ Anodic Stripping Voltammetry Using a Track-etched Microporous Membrane Electrode
    Hitoshi Mizuguchi
    Kentaro Numata
    Chiaki Monma
    Masamitsu Iiyama
    Kazuhiro Tachibana
    Tatsuo Nishina
    Junichi Shida
    Analytical Sciences, 2013, 29 : 949 - 954
  • [28] Determination of Ultra-trace Mercury(II) by Flow-injection/Anodic Stripping Voltammetry Using a Track-etched Microporous Membrane Electrode
    Mizuguchi, Hitoshi
    Numata, Kentaro
    Monma, Chiaki
    Iiyama, Masamitsu
    Tachibana, Kazuhiro
    Nishina, Tatsuo
    Shida, Junichi
    ANALYTICAL SCIENCES, 2013, 29 (10) : 949 - 954
  • [29] A Preconcentration Procedure for Determination of Ultra-Trace Mercury (II) in Environmental Samples Employing Continuous-Flow Cold Vapor Atomic Absorption Spectrometry
    Adlnasab, Laleh
    Ebrahimzadeh, Homeira
    Asgharinezhad, Ali Akbar
    Aghdam, Mahnaz Nasiri
    Dehghani, Ali
    Esmaeilpour, Sousan
    FOOD ANALYTICAL METHODS, 2014, 7 (03) : 616 - 628
  • [30] Recent advances in ultra-trace determination of uranium in natural water using total reflection X-ray fluorescence (TXRF) spectrometry
    Sanyal, Kaushik
    Dhara, Sangita
    X-RAY SPECTROMETRY, 2024, 53 (05) : 326 - 339