An Efficient Fluorescent Chemosensing Probe for Total Determination and Speciation of Ultra-Trace Levels of Mercury (II) Species in Water

被引:0
|
作者
Alwael, H. [1 ]
Alzahrani, K. A. [1 ,2 ]
Abduljabbar, T. N. [1 ]
Alharthi, A. S. [1 ,3 ]
Alshareef, F. M. [1 ]
Bahaidarah, E. A. [1 ]
Alkhraije, A. A. [1 ,4 ]
El-Shahawi, M. S. [1 ,5 ]
机构
[1] King Abdulaziz Univ, Fac Sci, Dept Chem, POB 80203, Jeddah 21589, Saudi Arabia
[2] King Abdulaziz Univ, Ctr Excellence Adv Mat Res CEAMR, Jeddah 21589, Saudi Arabia
[3] Umm Al Qura Univ, Fac Sci Appl, Dept Chem, Mecca, Saudi Arabia
[4] Umm AL Qura Univ, Al Leith Univ Coll, Dept Chem, Mecca, Al Leith, Saudi Arabia
[5] Damietta Univ, Fac Sci, Dept Chem, Dumyat, Egypt
关键词
Chemical equilibria; Extractive spectrofluorimetry; mercury (ii) determination and speciation; Rose Bengal; Ternary complex ion associate; AQUEOUS-SOLUTIONS; PRECONCENTRATION; EXTRACTION; SPECTROMETRY; ENHANCEMENT; REMOVAL; FISH;
D O I
10.1007/s10895-024-03999-w
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The current study reports a novel fluorescent chemosensor based on the tagging agent 4,5,6,7-tetrachloro-2',4',5',7'-tetraiodofluorescein (Rose Bengal, RB) for detection of trace levels of Hg2+in environmental water. The established probe has been based upon liquid-liquid extraction (LLE) of the developed ternary complex ion associate {[Hg (bpy)2]2+.[RB]2-} of Hg2+ -2,2- bipyridyl complex [Hg (bpy)2]2+ and RB at pH 9.0 onto chloroform and measuring the resulting fluorescence enhancement signal intensity at lambda ex/em = 570/ (580-600) nm. The limits of detection (LOD) and quantification (LOQ) of for Hg2+ was calculated to be 6.06 and 20 nM with a linear dynamic range (LDR) of 0.02-20 mu M, respectively. The stability constant, stoichiometry, chemical equilibria, and the thermodynamic parameters (Delta H, Delta S, and Delta G) of the developed ion associate were evaluated and assigned. Student's t and F tests at 95% confidence were fruitfully used for validation of the proposed methodology for Hg2+ detection in water samples with the aid of inductively coupled plasma-optical emission spectrometry (ICP-OES). The established strategy was successfully applied for detection of trace levels of Hg2+ in water samples with acceptable results. The proposed probe was satisfactorily applied for total determination and speciation of Hg in various water samples. Integrating the functional chelating agent onto associate formation to improve the selectivity and sensing properties of the LLE combining sensing probe towards target analyte in water represent the main interest.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Ultra-trace determination of total mercury in Italian bottled waters
    Varde, Massimiliano
    Servidio, Alessandro
    Vespasiano, Giovanni
    Pasti, Luisa
    Cavazzini, Alberto
    Di Traglia, Mario
    Rosselli, Annalisa
    Cofone, Franco
    Apollaro, Carmine
    Cairns, Warren R. L.
    Scalabrin, Elisa
    De Rosa, Rosanna
    Procopio, Antonio
    CHEMOSPHERE, 2019, 219 : 896 - 913
  • [2] Voltammetric determination of ultra-trace total mercury and toxic metals in meals
    Locatelli, Clinio
    Melucci, Dora
    FOOD CHEMISTRY, 2012, 130 (02) : 460 - 466
  • [3] Mutual interference problems in the simultaneous voltammetric determination of ultra-trace total mercury(ii) and toxic metals in medicinal herbs matrices
    Locatelli, C.
    Melucci, D.
    Locatelli, M.
    PLANTA MEDICA, 2012, 78 (11) : 1256 - 1256
  • [4] Determination of Trace Levels of Cu(II) or Hg(II) in Water Samples by a Thiourea-based Fluorescent Probe
    Pinzhu Qin
    Chenggang Niu
    Guangming Zeng
    Jianhua Zhu
    Lin Yue
    Analytical Sciences, 2008, 24 : 1205 - 1208
  • [5] Determination of trace levels of Cu(II) or Hg(II) in water samples by a thiourea-based fluorescent probe
    Qin, Pinzhu
    Niu, Chenggang
    Zeng, Guangming
    Zhu, Jianhua
    Yue, Lin
    ANALYTICAL SCIENCES, 2008, 24 (09) : 1205 - 1208
  • [6] Determination of trace levels of Cu(II) or Hg(II) in water samples by a thiourea-based fluorescent probe
    College of Environmental Science and Engineering, Hunan University, Changsha 410082, Hunan, China
    不详
    Anal. Sci., 9 (1205-1208):
  • [7] Voltammetric method for ultra-trace determination of total mercury and toxic metals in vegetables. Comparison with spectroscopy
    Locatelli, Clinio
    Melucci, Dora
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2013, 11 (05): : 790 - 800
  • [8] Determination of 210Pb at ultra-trace levels in water by ICP-MS
    Larivière, D
    Reiber, KM
    Evans, RD
    Cornett, RJ
    ANALYTICA CHIMICA ACTA, 2005, 549 (1-2) : 188 - 196
  • [9] Ultra-trace determination of mercury in water by cold-vapor generation isotope dilution mass spectrometry
    Yang, L
    Willie, S
    Sturgeon, RE
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (11) : 1226 - 1231
  • [10] Determination of thallium at ultra-trace levels in water and biological samples using solid phase spectrophotometry
    Amin, Alaa S.
    El-Sharjawy, Abdel-Azeem M.
    Kassem, Mohammed A.
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2013, 110 : 262 - 268