Accuracy of an autonomous dental implant robotic system in dental implant surgery

被引:1
|
作者
Wu, Yu [1 ]
Zou, Shiqi [1 ]
Lv, Pin [1 ]
Wang, Xiao [1 ]
机构
[1] Peking Univ, Dept Stomatol, Hosp 3, 49 North Garden Rd, Beijing 100191, Peoples R China
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2025年 / 133卷 / 03期
关键词
PLACEMENT; FAILURES;
D O I
10.1016/j.prosdent.2024.07.020
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Autonomous dental implant robot systems (ADIRSs) have been marketed for dental implant surgery; however, research on their accuracy is limited. Purpose. The purpose of this clinical study was to examine the accuracy of an ADIRS. Material and methods. Seventy-four participants with partial edentulism underwent implant surgery by using the ADIRS. Before surgery, a cone beam computed tomography (CBCT) scan was conducted, and its image data were fed into the ADIRS navigation and positioning system for iterative reconstruction and surgical path planning. After local anesthesia administration, area disinfection, and patient registration, the robot prepared the osteotomy and placed the implant under guidance of the navigation system. A postoperative CBCT scan was made to assess deviations between the planned and actual implant positions. The global coronal, apical, and angular deviations were measured and analyzed. A generalized linear mixed model (GLMM) was used to compare the differences in major outcome variables (alpha=.05). Results. All implant procedures were successfully carried out without any complications during surgery. A total of 86 implants were placed in 74 participants. The mean +/- standard deviation global coronal deviation, global apical deviation, and angular deviation was 0.61 +/- 0.20 mm (95% CI: 0.23 to 1.0 mm), 0.79 +/- 0.32 mm (95% CI: 0.17 to 1.41 mm), and 2.56 +/- 1.10 degrees (95% CI: 0.42 to 4.70 degrees), respectively. The findings from the GLMM revealed that the implant region (premolar, molar; maxilla, mandible; left, right), implant length, and surgeon did not significantly impact accuracy (P>.05). Conclusions. ADIRS showed high accuracy for implant placement because of the control of angular deviation and axial errors. The implant region, implant length, and surgeon had no significant influence on the accuracy of implant placement. Nevertheless, more clinical studies are required to support evidence-based clinical outcomes. (J Prosthet Dent 2025;133:764-770)
引用
收藏
页码:764 / 770
页数:7
相关论文
共 50 条
  • [1] Accuracy of implant site preparation in robotic navigated dental implant surgery
    Linn, Thu Ya
    Salamanca, Eisner
    Aung, Lwin Moe
    Huang, Ta-Ko
    Wu, Yi-Fan
    Chang, Wei-Jen
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2023, 25 (05) : 881 - 891
  • [2] Accuracy of an autonomous dental implant robotic system versus static guide-assisted implant surgery: A retrospective clinical study
    Jia, Shasha
    Wang, Guowei
    Zhao, Yimin
    Wang, Xiaojing
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (03): : 771 - 779
  • [3] Accuracy of an autonomous dental implant robotic system in partial edentulism: A pilot clinical study
    Wang, MiaoZhen
    Liu, Feng
    Yu, Tao
    Zhan, Yalin
    Ma, Feifei
    Rausch-Fan, Xiaohui
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (07)
  • [4] Optics-guided Robotic System for Dental Implant Surgery
    Biao Yan
    Wenlong Zhang
    Lijing Cai
    Lingxiang Zheng
    Kaiyang Bao
    Yuming Rao
    Lin Yang
    Weitao Ye
    Peifeng Guan
    Wei Yang
    Jiang Li
    Rongqian Yang
    Chinese Journal of Mechanical Engineering, 2022, 35 (03) : 149 - 161
  • [5] Optics-guided Robotic System for Dental Implant Surgery
    Yan, Biao
    Zhang, Wenlong
    Cai, Lijing
    Zheng, Lingxiang
    Bao, Kaiyang
    Rao, Yuming
    Yang, Lin
    Ye, Weitao
    Guan, Peifeng
    Yang, Wei
    Li, Jiang
    Yang, Rongqian
    CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2022, 35 (01)
  • [6] Optics-guided Robotic System for Dental Implant Surgery
    Biao Yan
    Wenlong Zhang
    Lijing Cai
    Lingxiang Zheng
    Kaiyang Bao
    Yuming Rao
    Lin Yang
    Weitao Ye
    Peifeng Guan
    Wei Yang
    Jiang Li
    Rongqian Yang
    Chinese Journal of Mechanical Engineering, 2022, 35
  • [7] Accuracy of immediate dental implant placement with task-autonomous robotic system and navigation system: An in vitro study
    Chen, Jinyan
    Zhuang, Minjie
    Tao, Baoxin
    Wu, Yiqun
    Ye, Lijuan
    Wang, Feng
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 973 - 983
  • [8] Accuracy of haptic robotic guidance of dental implant surgery for completely edentulous arches
    Bolding, Scotty L.
    Reebye, Uday N.
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04): : 639 - 647
  • [9] Accuracy of autonomous robotic surgery for dental implant placement in fully edentulous patients: A retrospective case series study
    Li, Ping
    Chen, Jiahao
    Li, An
    Luo, Ke
    Xu, Shulan
    Yang, Shuo
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (12) : 1428 - 1437
  • [10] A Vision-Guided Robotic System for Safe Dental Implant Surgery
    Pisla, Daria
    Bulbucan, Vasile
    Hedesiu, Mihaela
    Vaida, Calin
    Zima, Ionut
    Mocan, Rares
    Tucan, Paul
    Dinu, Cristian
    Pisla, Doina