Unsupervised motion artifacts reduction for cone-beam CT via enhanced landmark detection

被引:0
作者
Viriyasaranon, Thanaporn [1 ,4 ]
Ma, Serie [2 ]
Thies, Mareike [3 ]
Maier, Andreas [3 ]
Choi, Jang-Hwan [1 ,4 ]
机构
[1] Ewha Womans Univ, Dept Artificial Intelligence, Seoul 03760, South Korea
[2] Ewha Womans Univ, Grad Program Syst Hlth Sci & Engn, Div Mech & Biomed Engn, Seoul 03760, South Korea
[3] Friedrich Alexander Univ Erlangen Nurnberg, Pattern Recognit Lab, D-91054 Erlangen, Germany
[4] Ewha Womans Univ, Dept Computat Med, Grad Program Syst Hlth Sci & Engn, Seoul 03760, South Korea
基金
新加坡国家研究基金会;
关键词
Cone-beam CT; Motion artifacts; Multitask learning; Unsupervised learning; Hybrid transformer-CNN; Anatomical landmark detection; Multiresolution heatmap learning; Dynamic landmark motion estimation;
D O I
10.1016/j.eswa.2025.127258
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Motion artifacts in cone-beam computed tomography (CBCT) primarily result from patient movement during the scanning process, which can compromise diagnostic accuracy. Emerging deep learning-based techniques have shown promise in mitigating these artifacts; however, they often rely on motion-free CBCT reconstructions for training, which poses practical challenges in clinical settings. An alternative approach involves leveraging the positions of metallic fiducial markers for motion estimation. While effective, this method is time-intensive and requires additional equipment installation, limiting its practicality. To address these challenges, we propose the Dynamic Landmark Motion Estimation (DLME) method, designed to reduce high-frequency noise and errors in landmark detection, thereby enhancing image quality. DLME is powered by the proposed TriForceNet, a novel landmark detection framework that integrates a sequential hybrid transformer-convolutional neural network architecture, multiresolution heatmap learning, and a multitask learning strategy augmented with an auxiliary segmentation head to improve motion estimation accuracy. Experimental evaluations demonstrate that TriForceNet achieves superior performance compared to state-of-the-art landmark detectors on twodimensional projection images from the 4D extended cardiac-torso head phantom (XCAT) dataset, real patient CT scans from the CQ500 dataset, and knee regions from the CT scans in the VSD full body dataset. Furthermore, the DLME methodology outperforms traditional unsupervised motion compensation techniques and surpasses supervised, image-based motion artifact reduction methods across these datasets. The source code for the proposed model is publicly available at https://github.com/Thanaporn09/TriForceNet.git.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Feasibility of Cone-beam CT based treatment planning
    Yoo, S.
    Yin, F.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1831 - 1834
  • [42] Advanced cone-beam CT venous angiographic imaging
    Srinivasan, Visish M.
    Chintalapani, Gouthami
    Duckworth, Edward A. M.
    Kan, Peter
    JOURNAL OF NEUROSURGERY, 2018, 129 (01) : 114 - 120
  • [43] Image quality of flat panel cone-beam CT
    Rose, G
    Wiegert, J
    Schäfer, D
    Fiedler, K
    Conrads, N
    Timmer, J
    Rasche, V
    Noordhoek, N
    Klotz, E
    Koppe, R
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 677 - 683
  • [44] An empirical method for lag correction in cone-beam CT
    Mail, N.
    Moseley, D. J.
    Siewerdsen, J. H.
    Jaffray, D. A.
    MEDICAL PHYSICS, 2008, 35 (11) : 5187 - 5196
  • [45] The contribution of Cone-Beam CT in the assessment of orofacial pain
    Langlais, R. -P.
    Mah, P.
    Goulet, J. -P.
    DOULEUR ET ANALGESIE, 2009, 22 (02): : 112 - 120
  • [46] Image-Based Motion Compensation for High-Resolution Extremities Cone-Beam CT
    Sisniega, A.
    Stayman, J. W.
    Cao, Q.
    Yorkston, J.
    Siewerdsen, J. H.
    Zbijewski, W.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [47] An in vitro evaluation of cone-beam breast CT methods
    Zeng, Kai
    Fajardo, Laurie L.
    Kao, Simon
    Franken, Edmund A.
    Park, Jeong Mi
    Jing, Zhenxue
    Bai, Er-wei
    Wang, Ge
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2008, 16 (03) : 171 - 187
  • [48] Dose calculation using megavoltage cone-beam CT
    Morin, Olivier
    Chen, Josephine
    Aubin, Michele
    Gillis, Amy
    Aubry, Jean-Francois
    Bose, Supratik
    Chen, Hong
    Descovich, Martina
    Xia, Ping
    Pouliot, Jean
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (04): : 1201 - 1210
  • [49] Flying focal spot (FFS) in cone-beam CT
    Kachelriess, Marc
    Knaup, Michael
    Penssel, Christian
    Kalender, Willi A.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 1238 - 1247
  • [50] Design and Characterization of a Dedicated Cone-Beam CT Scanner for Detection of Acute Intracranial Hemorrhage
    Xu, J.
    Sisniega, A.
    Zbijewski, W.
    Dang, H.
    Stayman, J. W.
    Wang, X.
    Foos, D. H.
    Aygun, N.
    Koliatsos, V. E.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783