Unsupervised motion artifacts reduction for cone-beam CT via enhanced landmark detection

被引:0
|
作者
Viriyasaranon, Thanaporn [1 ,4 ]
Ma, Serie [2 ]
Thies, Mareike [3 ]
Maier, Andreas [3 ]
Choi, Jang-Hwan [1 ,4 ]
机构
[1] Ewha Womans Univ, Dept Artificial Intelligence, Seoul 03760, South Korea
[2] Ewha Womans Univ, Grad Program Syst Hlth Sci & Engn, Div Mech & Biomed Engn, Seoul 03760, South Korea
[3] Friedrich Alexander Univ Erlangen Nurnberg, Pattern Recognit Lab, D-91054 Erlangen, Germany
[4] Ewha Womans Univ, Dept Computat Med, Grad Program Syst Hlth Sci & Engn, Seoul 03760, South Korea
基金
新加坡国家研究基金会;
关键词
Cone-beam CT; Motion artifacts; Multitask learning; Unsupervised learning; Hybrid transformer-CNN; Anatomical landmark detection; Multiresolution heatmap learning; Dynamic landmark motion estimation;
D O I
10.1016/j.eswa.2025.127258
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Motion artifacts in cone-beam computed tomography (CBCT) primarily result from patient movement during the scanning process, which can compromise diagnostic accuracy. Emerging deep learning-based techniques have shown promise in mitigating these artifacts; however, they often rely on motion-free CBCT reconstructions for training, which poses practical challenges in clinical settings. An alternative approach involves leveraging the positions of metallic fiducial markers for motion estimation. While effective, this method is time-intensive and requires additional equipment installation, limiting its practicality. To address these challenges, we propose the Dynamic Landmark Motion Estimation (DLME) method, designed to reduce high-frequency noise and errors in landmark detection, thereby enhancing image quality. DLME is powered by the proposed TriForceNet, a novel landmark detection framework that integrates a sequential hybrid transformer-convolutional neural network architecture, multiresolution heatmap learning, and a multitask learning strategy augmented with an auxiliary segmentation head to improve motion estimation accuracy. Experimental evaluations demonstrate that TriForceNet achieves superior performance compared to state-of-the-art landmark detectors on twodimensional projection images from the 4D extended cardiac-torso head phantom (XCAT) dataset, real patient CT scans from the CQ500 dataset, and knee regions from the CT scans in the VSD full body dataset. Furthermore, the DLME methodology outperforms traditional unsupervised motion compensation techniques and surpasses supervised, image-based motion artifact reduction methods across these datasets. The source code for the proposed model is publicly available at https://github.com/Thanaporn09/TriForceNet.git.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] A Validation Framework for Head-Motion Artifacts in Dental Cone-Beam CT
    Ens, S.
    Bruder, R.
    Ulrici, J.
    Hell, E.
    Buzug, T. M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 658 - 661
  • [2] Crescent artifacts in cone-beam CT
    Giles, William
    Bowsher, James
    Li, Hao
    Yin, Fang-Fang
    MEDICAL PHYSICS, 2011, 38 (04) : 2116 - 2121
  • [3] Simulation of Motion Artifacts in Offset Flat-Panel Cone-Beam CT
    Hansis, Eberhard
    Shao, Lingxiong
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2471 - 2475
  • [4] Metal artifacts correction in cone-beam CT bone imaging
    Zhang, Yan
    Ning, Ruola
    Conover, David
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [5] AUTOMATIC DETECTION OF PATIENT MOTION IN CONE-BEAM COMPUTED TOMOGRAPHY
    Ens, S.
    Ulrici, J.
    Hell, E.
    Buzug, T. M.
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 1257 - 1260
  • [6] Deformable motion compensation for interventional cone-beam CT
    Capostagno, S.
    Sisniega, A.
    Stayman, J. W.
    Ehtiati, T.
    Weiss, C. R.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05)
  • [7] An energy minimization method for the correction of cupping artifacts in cone-beam CT
    Xie, Shipeng
    Zhuang, Wenqin
    Li, Haibo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 307 - 319
  • [8] Two methods for reducing moving metal artifacts in cone-beam CT
    Hahn, Andreas
    Knaup, Michael
    Brehm, Marcus
    Sauppe, Sebastian
    Kachelriess, Marc
    MEDICAL PHYSICS, 2018, 45 (08) : 3671 - 3680
  • [9] Reducing metal artifacts in cone-beam CT images by preprocessing projection data
    Zhang, Yongbin
    Zhang, Lifei
    Zhu, Ronald
    Lee, Andrew K.
    Chambers, Mark
    Dong, Lei
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (03): : 924 - 932
  • [10] Cupping artifacts analysis and correction for a FPD-based cone-beam CT
    Zhang Li
    Gao Hewei
    Li Shuanglei
    Chen Zhiqiang
    Xing Yuxiang
    COMPUTATIONAL IMAGING IV, 2006, 6065