Embolic Effect of Different Cyanoacrylates: Radiological and Histological Comparison in an In Vivo Rabbit Renal-Artery Model

被引:0
作者
Comby, Pierre-Olivier [1 ,2 ]
Guillen, Kevin [2 ,3 ]
Chevallier, Olivier [2 ,3 ]
Couloumy, Emilie [4 ]
Dencausse, Anne [4 ]
Robert, Philippe [4 ]
Catoen, Sarah [4 ]
Salsac, Anne-Virginie [5 ]
Aho-Glele, Serge Ludwig [6 ]
Loffroy, Romaric [2 ,3 ]
机构
[1] Francois Mitterrand Univ Hosp, Image Guided Therapy Ctr, Dept Neuroradiol & Emergency Radiol, F-21079 Dijon, France
[2] Univ Bourgogne, ICMUB Lab, CNRS, UMR 6302, F-210000 Dijon, France
[3] Francois Mitterrand Univ Hosp, Image Guided Therapy Ctr, Dept Vasc & Intervent Radiol, F-21079 Dijon, France
[4] Guerbet Res, R&D, F-95943 Roissy Charles Degaulle, France
[5] Univ Technol Compiegne, CNRS, Biomech & Bioengn Lab, UMR 7338, F-60203 Compiegne, France
[6] Francois Mitterrand Univ Hosp, Dept Epidemiol Stat & Clin Res, F-21079 Dijon, France
关键词
Embolization; Renal artery; Cyanoacrylate; Rabbit model; Micro-CT; EMBOLIZATION; GLUE; POLYMERIZATION; HISTOTOXICITY; EXPERIENCE; EFFICACY; AGENTS;
D O I
10.1007/s00270-025-03997-w
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose To compare the radiological and histological effects of three different cyanoacrylate glues used for in vivo renal artery embolization in rabbits. Materials and Methods N-butyl cyanoacrylate (NBCA), NBCA-methacryloxysulfolane (NBCA-MS), and alpha-hexyl-cyanoacrylate (AHCA) were each used to embolize five renal arteries under free-flow conditions with a 1:3 glue/ethiodized oil ratio. The rabbits were euthanized 30 min after embolization. Micro-computed tomography (CT) was used to assess glue cast distribution (extent of penetration into the vascular tree), fragmentation (presence of discontinuities within the cast), and heterogeneity (variability in cast density). Histological slides were analyzed for lumen dilatation, intimal arteritis, necrosis, and peri-arterial edema. Statistical analyses were performed using the Kruskal-Wallis test. Results Glue penetration into interlobar and corticomedullary arteries was observed consistently in all three groups. Fragmentation scores showed no significant differences between glue types, but AHCA demonstrated significantly lower heterogeneity in proximal arteries compared to NBCA-MS (P = 0.019). Severe lumen dilatation and intimal necrosis were observed in all samples, whereas intimal arteritis was significantly less severe with AHCA compared to NBCA-MS (P < 0.001). No significant differences in peri-arterial edema were found between groups. Conclusion Micro-CT features were similar with all three glues. AHCA produced greater cast uniformity and less intimal arteritis, suggesting a role in endovascular embolization.
引用
收藏
页数:11
相关论文
共 2 条
  • [1] Blocked- fl ow vs. freefl ow cyanoacrylate glue embolization: Histological differences in an in vivo rabbit renal artery model
    Comby, Pierre-Olivier
    Guillen, Kevin
    Chevallier, Olivier
    Couloumy, Emilie
    Dencausse, Anne
    Robert, Philippe
    Catoen, Sarah
    Salsac, Anne-Virginie
    Aho-Glele, Serge Ludwig
    Loffroy, Romaric
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (04) : 137 - 143
  • [2] Comparison of branch and distally focused main renal artery denervation using two different radio-frequency systems in a porcine model
    Mahfoud, Felix
    Pipenhagen, Catherine A.
    Moon, L. Boyce
    Ewen, Sebastian
    Kulenthiran, Saarraaken
    Fish, Jeffrey M.
    Jensen, James A.
    Virmani, Renu
    Joner, Michael
    Yahagi, Kazuyuki
    Tsioufis, Costas
    Boehm, Michael
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 241 : 373 - 378