Endoscopic Ultrasound-guided Transmural Biliary Drainage With 6 mm and 8 mm Cautery-enhanced Lumen-apposing Metal Stents

被引:0
|
作者
Ramai, Daryl [1 ]
Dawod, Enad [2 ]
Darwin, Peter E. [3 ]
Kim, Raymond E. [3 ]
Kim, Jeong Hoon [4 ]
Wang, Jade [5 ]
Lanka, Chandana [6 ]
Bakain, Tarek [7 ]
Mahadev, Srihari [2 ]
Sampath, Kartik [2 ]
Carr-Locke, David L. [2 ]
Morris, John D. [1 ]
Sharaiha, Reem Z. [2 ]
机构
[1] Univ Utah Hlth, Div Gastroenterol & Hepatol, Salt Lake City, UT USA
[2] New York Presbyterian, Weill Cornell Med Coll, Div Gastroenterol & Hepatol, New York, NY 10038 USA
[3] Univ Maryland, Med Ctr, Div Gastroenterol & Hepatol, Baltimore, MD USA
[4] Univ Pittsburgh, Sch Med, Dept Med, Pittsburgh, PA USA
[5] New York Presbyterian, Weill Cornell Med Coll, Div Med, New York, NY USA
[6] Mt Sinai South Nassau, Dept Med, Oceanside, NY USA
[7] Medstar Washington Hosp Ctr, Dept Med, Washington, DC USA
关键词
EUS; LAMS; biliary; CHOLEDOCHODUODENOSTOMY; MULTICENTER; OBSTRUCTION;
D O I
10.1097/MCG.0000000000002043
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objective:Endoscopic retrograde cholangiopancreatography (ERCP) may be unsuccessful in patients with duodenal stenosis or malignant ampullary infiltration. Endoscopic ultrasound-guided biliary drainage (EUS-BD) has been proposed as an alternative. We aimed to assess the efficacy and safety of EUS-BD for malignant distal bile duct obstruction using the newly introduced smaller caliber 6 or 8 mm cautery-enhanced lumen-apposing metal stent.Methods:A multicenter retrospective study was performed on patients with unresectable malignant distal bile duct obstruction who underwent EUS-BD between 2021 and 2022 after unsuccessful ERCP.Results:Thirty-two patients were included [7 (53.13%) males], with a mean age of 72.2 +/- 12.5 years. The technical success rate was 100%. Altered anatomy was present in 2 (6.25%). The indication for drainage was biliary obstruction from pancreatic cancer in 26 patients (84.5%), cholangiocarcinoma in 3 (9.4%), and ampullary mass in 3 (9.4%). The procedure was performed mostly in an outpatient setting (n = 19, 59.38%). The clinical success rate was 92.3% [bilirubin: 14.1 (SD: 8.9) preprocedure vs 4.9 (SD: 1.1) postprocedure; P = 0.0001]. There was one early adverse event of a perforation, which was closed endoscopically and drained percutaneously. Delayed adverse events included food impaction of the stent (n = 1), which was resolved with a repeat procedure and insertion of a double pigtail stent.Conclusion:This study demonstrates the feasibility of EUS-BD drainage using smaller caliber 6 or 8 mm lumen-apposing metal stent to relieve malignant distal bile duct obstruction in patients who fail conventional ERCP.
引用
收藏
页码:376 / 383
页数:8
相关论文
共 50 条
  • [21] Endoscopic ultrasonography-guided biliary drainage for malignant jaundice by using electrocautery-enhanced lumen-apposing metal stents (Hot-SPAXUS stent)
    Manta, Raffaele
    Torrisi, Sabrina
    Castellani, Danilo
    Germani, Ugo
    Zito, Francesco P.
    Morelli, Olivia
    Brunori, Paolo M.
    Zullo, Angelo
    De Francesco, Vincenzo
    ANNALS OF GASTROENTEROLOGY, 2022, 35 (06): : 663 - 667
  • [22] Multicenter study of lumen-apposing metal stents with or without pigtail in endoscopic ultrasound-guided biliary drainage for malignant obstruction—BAMPI TRIAL: an open-label, randomized controlled trial protocol
    Albert Garcia-Sumalla
    Carme Loras
    Vicente Sanchiz
    Rafael Pedraza Sanz
    Enrique Vazquez-Sequeiros
    Jose Ramon Aparicio
    Carlos de la Serna-Higuera
    Daniel Luna-Rodriguez
    Xavier Andujar
    María Capilla
    Tatiana Barberá
    Jose Ramon Foruny-Olcina
    Belen Martínez
    Miguel Dura
    Silvia Salord
    Berta Laquente
    Cristian Tebe
    Sebastia Videla
    Manuel Perez-Miranda
    Joan B. Gornals
    Trials, 23
  • [23] Anchoring lumen-apposing metal stent with coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: any benefit?
    Ali, Saad Emhmed
    Benrajab, Karim
    Mardini, Houssam
    Su, Leon
    Gabr, Moamen
    Frandah, Wesam M.
    ANNALS OF GASTROENTEROLOGY, 2019, 32 (06): : 620 - 625
  • [24] Safety issues in endoscopy ultrasound-guided interventions using lumen apposing metal stents
    Auriemma, Francesco
    Fugazza, Alessandro
    Colombo, Matteo
    Spadaccini, Marco
    Repici, Alessandro
    Anderloni, Andrea
    MINERVA GASTROENTEROLOGY, 2022, 68 (02): : 177 - 185
  • [25] EUS-guided drainage of postsurgical pelvic abscesses using lumen-apposing metal stents
    Lopez-Fernandez, Eduardo
    Ruiz-Zorrilla, Rafael
    Curieses-Luengo, Maria
    Alvarez-Alvaree, Aranzazu
    de-la-Coba-Ortiz, Cristobal
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2019, 111 (07) : 566 - 567
  • [26] Multicenter study of lumen-apposing metal stents with or without pigtail in endoscopic ultrasound-guided biliary drainage for malignant obstruction-BAMPI TRIAL: an open-label, randomized controlled trial protocol
    Garcia-Sumalla, Albert
    Loras, Carme
    Sanchiz, Vicente
    Pedraza Sanz, Rafael
    Vazquez-Sequeiros, Enrique
    Ramon Aparicio, Jose
    de la Serna-Higuera, Carlos
    Luna-Rodriguez, Daniel
    Andujar, Xavier
    Capilla, Maria
    Barbera, Tatiana
    Foruny-Olcina, Jose Ramon
    Martinez, Belen
    Dura, Miguel
    Salord, Silvia
    Laquente, Berta
    Tebe, Cristian
    Videla, Sebastia
    Perez-Miranda, Manuel
    Gornals, Joan B.
    TRIALS, 2022, 23 (01)
  • [27] Lumen-apposing metals stents in advanced endoscopic ultrasound-guided interventions: novel applications, potential complications and radiologic assessment
    Li, Jessica
    Basseri, Hamed
    Donnellan, Fergal
    Harris, Alison
    ABDOMINAL RADIOLOGY, 2021, 46 (02) : 776 - 791
  • [28] Managing dysfunctions and reinterventions in endoscopic ultrasound-guided choledochoduodenostomy with lumen apposing metal stents: Illustrated technical review (with videos)
    Vanella, Giuseppe
    Dell'Anna, Giuseppe
    van Wanrooij, Roy L. J.
    Bronswijk, Michiel
    Voermans, Rogier P.
    Laleman, Wim
    van Malenstein, Hannah
    Fockens, Paul
    van der Merwe, Schalk
    Arcidiacono, Paolo Giorgio
    DIGESTIVE ENDOSCOPY, 2024, 36 (04) : 481 - 491
  • [29] Safety and efficacy of lumen-apposing metal stents and double-pigtail plastic stents for endoscopic ultrasound-guided drainage of walled-off necrosis; a systematic review and meta-analysis
    Khizar, Hayat
    Yufei, Hu
    Yanhua, Wu
    Wangyang, Chen
    Ying, Bian
    Chenyu, Le
    Zhicheng, Huang
    Ali, Kamran
    Jianfeng, Yang
    ANNALS OF MEDICINE, 2023, 55 (01) : 578 - 591
  • [30] Endoscopic ultrasound-guided choledochoduodenostomy using a lumen apposing metal stent for acute cholangitis
    Sandru, Vasile
    Ilie, Madalina
    Plotogea, Oana
    Ungureanu, Bogdan Silviu
    Stoica, Adina
    Gheonea, Dan Ionut
    Constantinescu, Gabriel
    TURKISH JOURNAL OF GASTROENTEROLOGY, 2018, 29 (04) : 511 - 514