Effect of systemic lidocaine infusion on optic nerve sheath diameter during laparoscopic hysterectomy: a randomized controlled study

被引:1
|
作者
Rehab, Osama M. [1 ]
Elsharkawy, Mohammed S. [1 ]
Bakr, Doha M. [1 ,2 ]
Hassan, Adel A. [2 ]
机构
[1] Tanta Univ, Fac Med, Anesthesiol Surg Intens Care & Pain Management Dep, Ryad Ghoraba St,Tanta Qism 2, Tanta 31527, Egypt
[2] Helwan Univ, Fac Med, Anesthesiol Surg Intens Care & Pain Management Dep, Helwan, Egypt
关键词
Lidocaine; Optic nerve; Laparoscopy; Hysterectomy; CEREBRAL-BLOOD-FLOW; INTRACRANIAL-PRESSURE; TRENDELENBURG POSITION; INTRAVENOUS LIDOCAINE; SONOGRAPHIC ASSESSMENT; PROPOFOL ANESTHESIA; OXYGEN-SATURATION; ROBOTIC SURGERY; PNEUMOPERITONEUM; SEVOFLURANE;
D O I
10.23736/S0375-9393.24.18204-1
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: During laparoscopic hysterectomy (LH), the elevation of intra-abdominal and intra-thoracic pressures due to pneumoperitoneum (PP) results in an increase in intracranial pressure (ICP). The Trendelenburg position (TP) is an accentuating factor. This trial aimed to assess the effect of intravenous (IV) lidocaine infusion on optic nerve sheath diameter (ONSD), a widely accepted surrogate measure for ICP, during PP and TP. METHODS: A randomized, placebo-controlled study was conducted on 66 patients scheduled for LH, equally divided into a lidocaine group and a saline group. ONSD, the primary outcome, was recorded before induction (T1), before PP initiation in the supine position (T2), five minutes (T3), 30 minutes (T4), and 60 minutes (T5) after PP and TP, and five minutes after termination of PP in the supine position (T6). Secondary outcomes included numerical rating scale (NRS) scores at arrival to the post-anesthesia care unit (PACU), 6, 12, and 24 hours after surgery, and postoperative adverse effects. RESULTS: ONSD at T4 and T5 was significantly lower in the lidocaine group than in the saline group (T4: 4.94 +/- 0.43 mm vs. 5.27 +/- 0.37 mm; P =0.003, T5: 5.08 +/- 0.46 vs. 5.41 +/- 0.38 mm; P =0.004). The lidocaine group had significantly lower NRS values than the saline group only at PACU arrival (median [Q1-Q3]: 5 [4-6] vs. 6 [5-6.25]; P =0.016). Fewer patients in the lidocaine group experienced postoperative headache (P =0.029). CONCLUSIONS: IV lidocaine during LH can attenuate the ONSD distension, decrease pain scores at PACU arrival, and reduce the incidence of postoperative headache. ( Cite this article as: Rehab OM, Elsharkawy MS, Bakr DM, Hassan AA. Effect of systemic lidocaine infusion on optic nerve sheath diameter during laparoscopic hysterectomy: a randomized controlled study. Minerva Anestesiol 2024;90:727-38. DOI: 10.23736/S0375-9393.24.18204-1)
引用
收藏
页码:727 / 738
页数:12
相关论文
共 50 条
  • [1] The effect of pneumoperitoneum and Trendelenburg position on optic nerve sheath diameter in patients undergoing laparoscopic hysterectomy
    Bayramov, Tural
    Kilicaslan, Banu
    Akinci, Seda B.
    Boyraz, Gokhan
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2022, 48 (03) : 830 - 837
  • [2] Impact of controlled intraabdominal pressure on the optic nerve sheath diameter during laparoscopic procedures
    Fernando Dip
    David Nguyen
    Armando Rosales
    Morris Sasson
    Emanuele Lo Menzo
    Samuel Szomstein
    Raul Rosenthal
    Surgical Endoscopy, 2016, 30 : 44 - 49
  • [3] Impact of controlled intraabdominal pressure on the optic nerve sheath diameter during laparoscopic procedures
    Dip, Fernando
    Nguyen, David
    Rosales, Armando
    Sasson, Morris
    Lo Menzo, Emanuele
    Szomstein, Samuel
    Rosenthal, Raul
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2016, 30 (01): : 44 - 49
  • [4] Effect of Reverse Trendelenburg Position Applied Before Pneumoperitoneum on Optic Nerve Sheath Diameter in Laparoscopic Bariatric Surgery: A Randomized, Controlled Study
    Solmaz, Ali
    Demirgan, Serdar
    Burcu, Buesra
    Caliskan, Ozan
    Yagci, Selma
    Yilmaz, Ozlem
    Hacim, Nadir Adnan
    BARIATRIC SURGICAL PRACTICE AND PATIENT CARE, 2024, 19 (01) : 50 - 57
  • [5] Ultrasonographic measurement of optic nerve sheath diameter during laparoscopic surgeries in pediatric patients: An observational study
    Ray, Swarup
    Parmar, Uditi
    Dias, Raylene
    Saxen, Vishal
    Mujpurwala, Fatema
    Anu, K. A.
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2025, 41 (02) : 298 - 303
  • [6] Propofol attenuates the increase of sonographic optic nerve sheath diameter during robot-assisted laparoscopic prostatectomy: a randomized clinical trial
    Yu, Jihion
    Hong, Jun Hyuk
    Park, Jun-Young
    Hwang, Jai-Hyun
    Cho, Seong-Sik
    Kim, Young-Kug
    BMC ANESTHESIOLOGY, 2018, 18
  • [7] Comparison of the effects of desflurane and total intravenous anesthesia on the optic nerve sheath diameter in robot assisted laparoscopic radical prostatectomy A randomized controlled trial
    Choi, Eun-Su
    Jeon, Young-Tae
    Sohn, Hye-Min
    Kim, Dong-Woo
    Choi, Seok-Jun
    In, Chi-Bum
    MEDICINE, 2018, 97 (41)
  • [8] Effects of sevoflurane and propofol on the optic nerve sheath diameter in patients undergoing laparoscopic gynecological surgery: a randomized controlled clinical studies
    Geng, Weilian
    Chen, Changxing
    Sun, Xingfeng
    Huang, Shaoqiang
    BMC ANESTHESIOLOGY, 2021, 21 (01)
  • [9] Elevation in optic nerve sheath diameter due to the pneumoperitoneum and Trendelenburg is associated to postoperative nausea, vomiting and headache in patients undergoing laparoscopic hysterectomy
    Yilmaz, Gulseren
    Akca, Aysu
    Kiyak, Huseyin
    Salihoglu, Ziya
    MINERVA ANESTESIOLOGICA, 2020, 86 (03) : 270 - 276
  • [10] Position does not affect the optic nerve sheath diameter during laparoscopy
    Kim, Sang Hun
    Kim, Hyung Jin
    Jung, Ki Tae
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2015, 68 (04) : 358 - 363