Printing surface cuprous oxides featured liquid metal for non-enzymatic electrochemical glucose sensor

被引:2
|
作者
Luo, Yiyao [1 ]
Liao, Gengcheng [1 ]
Guo, Zixuan [1 ]
Huang, Zongyu [1 ,3 ]
Ren, Long [2 ]
Qi, Xiang [1 ]
机构
[1] Xiangtan Univ, Sch Phys & Optoelect, Human Key Lab Micronano Energy Mat & Devices, Xinxiang Rd,Xianfeng St, Xiangtan 411105, Hunan, Peoples R China
[2] Wuhan Univ Technol, Int Sch Mat Sci & Engn, State Key Lab Adv Technol Mat Synth & Proc, 122 Luoshi Rd, Wuhan 430070, Hubei, Peoples R China
[3] Hunan Univ, Human Key Lab Two dimens Mat, Changsha 410082, Hunan, Peoples R China
来源
SOFT SCIENCE | 2024年 / 4卷 / 01期
基金
中国国家自然科学基金;
关键词
Glucose sensor; liquid metal; cuprous oxide; printing biosensors; DIABETES MANAGEMENT; NANOPARTICLES; GROWTH;
D O I
10.20517/ss.2023.40
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Electrochemical glucose sensors that rely on two-dimensional (2D) oxides have attracted significant attention owing to the strong sensing activity of 2D oxides, but their practical application is hindered by the complexity and high cost of fabrication of electrodes and integrated devices. Herein, a convenient and effective fabrication route that includes printing a Ga-based liquid metal (LM) as a current collection electrode, followed by growing electrochemically active 2D oxides directly on the surface of Ga-based LMs under mild conditions, is developed for non-enzyme-based electrochemical sensors. Specifically, 2D annealed Cu-Oxide (ACO) is successfully grown on a printed Ga electrode through a galvanic replacement reaction, resulting in the formation of a mechanically and electrically well-matched interface between the active sensing materials and the current collection substrate. Benefitting from the high quantity of 2D ACO and good charge transfer at the interface, the as-prepared ACO electrode exhibits attractive glucose sensing performance, with a wide linear range (1 mu M-10 mM) of effective detection, low detection limit down to 1 mu M, and high sensitivity of 0.87 mu A<middle dot>mM(-1)<middle dot>cm(-2). Our study highlights the potential of using LMs in bio-sensing applications and provides a non-enzyme-based electrochemical biosensor platform for effective glucose detection in diets and clinical diagnostic settings.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Simple Electrochemical Synthesis of Cuprous Oxide Nanoparticles and Their Application as a Non-Enzymatic Glucose Sensor
    Khedekar, Vardhaman V.
    Bhanage, Bhalachandra M.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (06) : B248 - B251
  • [2] Preparing cuprous oxide nanomaterials by electrochemical method for non-enzymatic glucose biosensor
    Thu-Thuy Nguyen
    Bui The Huy
    Hwang, Seo-Young
    Nguyen Minh Vuong
    Quoc-Thai Pham
    Nguyen Ngoc Nghia
    Kirtland, Aaron
    Lee, Yong-Ill
    NANOTECHNOLOGY, 2018, 29 (20)
  • [3] Advances in non-enzymatic glucose sensors based on metal oxides
    Zhu, Hua
    Li, Li
    Zhou, Wei
    Shao, Zongping
    Chen, Xianjian
    JOURNAL OF MATERIALS CHEMISTRY B, 2016, 4 (46) : 7333 - 7349
  • [4] Non-Enzymatic Electrochemical Glucose Sensors Based on Metal Oxides and Sulfides: Recent Progress and Perspectives
    Zhu, Haibing
    Shi, Feng
    Peng, Maoying
    Zhang, Ye
    Long, Sitian
    Liu, Ruixin
    Li, Juan
    Yang, Zhanjun
    CHEMOSENSORS, 2025, 13 (01)
  • [5] Preparation and performance of non-enzymatic glucose sensor electrode based on nanometer cuprous oxide
    Yu, Xiaojiao
    Zhang, Jie
    Tang, Xiyan
    Wei, Yuchen
    Kou, Song
    Niu, Jinfen
    Yao, Binghua
    NANOMATERIALS AND NANOTECHNOLOGY, 2018, 8
  • [6] An effective metal-organic framework-based electrochemical non-enzymatic glucose sensor
    Daud, A. D.
    Lim, H. N.
    Ibrahim, I.
    Endot, N. A.
    Gowthaman, N. S. K.
    Jiang, Z. T.
    Cordova, Kyle E.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 921
  • [7] Non-enzymatic electrochemical sensing of glucose
    Guangfeng Wang
    Xiuping He
    Lingling Wang
    Aixia Gu
    Yan Huang
    Bin Fang
    Baoyou Geng
    Xiaojun Zhang
    Microchimica Acta, 2013, 180 : 161 - 186
  • [8] Non-enzymatic electrochemical sensing of glucose
    Wang, Guangfeng
    He, Xiuping
    Wang, Lingling
    Gu, Aixia
    Huang, Yan
    Fang, Bin
    Geng, Baoyou
    Zhang, Xiaojun
    MICROCHIMICA ACTA, 2013, 180 (3-4) : 161 - 186
  • [9] Electrochemical non-enzymatic glucose sensors
    Park, S
    Boo, H
    Chung, TD
    ANALYTICA CHIMICA ACTA, 2006, 556 (01) : 46 - 57
  • [10] NON-ENZYMATIC ELECTROCHEMICAL GLUCOSE DETECTION
    TINDALL, CE
    MCMULLEN, JK
    MORROW, DJ
    IRISH JOURNAL OF MEDICAL SCIENCE, 1985, 154 (07) : 288 - 288