Efficient Registration of Intraoral Point Clouds Using 3-D Spatial Consistent Grouping Method With Global Optimization

被引:0
作者
Wang, Zhen [1 ]
Chen, Mohan [2 ]
Chen, Sheng [1 ]
机构
[1] Univ Shanghai Sci & Technol, Dept Control, Shanghai 200093, Peoples R China
[2] Shanghai Univ Elect Power, Dept Instrumentat & Measurement, Shanghai 200093, Peoples R China
基金
中国国家自然科学基金;
关键词
Point cloud compression; Training; Three-dimensional displays; Data mining; Artificial intelligence; Signal to noise ratio; Image reconstruction; Accuracy; Surface treatment; Surface reconstruction; Intraoral scanning; point cloud; registration; DIGITAL IMPLANT IMPRESSIONS; ACCURACY; SCANNER;
D O I
10.1109/TIM.2025.3551013
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Intraoral 3-D scanning is a vital component of modern oral therapy. Because of the limited field of view (FOV) and degraded image quality of the intraoral scanner, matching the bundle of the intraoral dense point clouds with a low signal-to-noise ratio (SNR) in real time (approximately 25 point clouds per second) is challenging; consequently, the accuracy of the reconstructed full arch gets degraded. This study proposes an innovative matching method for intraoral point clouds with high efficiency, which involves a 3-D spatial consistent grouping (3D-SCG) method in the intraoral scanning scheme. First, the method introduces the Tooth-Net module, which is a multilayer neural network based on the attention mechanism, to achieve high-dimensional geometric features using the corresponding pairs between intraoral point clouds to be matched. Subsequently, outliers are removed based on the geometric features in the outlier removal module, which comprises Score-Net, nonmaximum suppression (NMS), and K-nearest neighbor (KNN) with spectral matching (SM). High confidence by Score-Net and well-distributed correspondences by NMS are converted into scores, and KNN is used to reduce the size of the high-score matrix. The weights generated by the SM module for each corresponding pair are used to calculate the best matching matrix. Four small- and four large-scale high-density intraoral point-cloud datasets are collected to validate the proposed method. Both small- and large-scale intraoral point clouds can be matched in real time. The overall time consumption is reduced by approximately 80% compared with the traditional matching method for intraoral point clouds, which is based on fast point feature histograms (FPFHs) with an iterative closest point (ICP) algorithm; nonetheless, the matching accuracy is comparable. Moreover, the matching failure rate is reduced by 33% during intraoral scanning. The proposed matching method based on 3D-SCG is efficient for intraoral point clouds with a low SNR and high density.
引用
收藏
页数:14
相关论文
共 40 条
  • [1] A METHOD FOR REGISTRATION OF 3-D SHAPES
    BESL, PJ
    MCKAY, ND
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) : 239 - 256
  • [2] Sparse Iterative Closest Point
    Bouaziz, Sofien
    Tagliasacchi, Andrea
    Pauly, Mark
    [J]. COMPUTER GRAPHICS FORUM, 2013, 32 (05) : 113 - 123
  • [3] Calibration of Intraoral 3-D Measurement System With Using Consummated Model Combined With Highly Accurate Data Pairs
    Chen, Sheng
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [4] Intraoral 3-D Measurement by Means of Group Coding Combined With Consistent Enhancement for Fringe Projection Pattern
    Chen, Sheng
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [5] Adaptively Alternative Light-Transport-Model-Based Three-Dimensional Optical Imaging for Longitudinal and Quantitative Monitoring of Gastric Cancer in Live Animal
    Chen, Xueli
    Yang, Defu
    Sun, Fangfang
    Cao, Xu
    Liang, Jimin
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (10) : 2095 - 2107
  • [6] Automatic Registration Between Dental Cone-Beam CT and Scanned Surface via Deep Pose Regression Neural Networks and Clustered Similarities
    Chung, Minyoung
    Lee, Jingyu
    Song, Wisoo
    Song, Youngchan
    Yang, Il-Hyung
    Lee, Jeongjin
    Shin, Yeong-Gil
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (12) : 3900 - 3909
  • [7] Registration of large-scale terrestrial laser scanner point clouds: A review and benchmark
    Dong, Zhen
    Liang, Fuxun
    Yang, Bisheng
    Xu, Yusheng
    Zang, Yufu
    Li, Jianping
    Wang, Yuan
    Dai, Wenxia
    Fan, Hongchao
    Hyyppa, Juha
    Stilla, Uwe
    [J]. ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2020, 163 : 327 - 342
  • [8] [杜威 Du Wei], 2023, [控制工程, Control Engineering of China], V30, P543
  • [9] A Pattern and Calibration Method for Single-Pattern Structured Light System
    Feng, Zexi
    Man, Duhu
    Song, Zhan
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (06) : 3037 - 3048
  • [10] Precision of Dental Implant Digitization Using Intraoral Scanners
    Fluegge, Tabea V.
    Att, Wael
    Metzger, Marc C.
    Nelson, Katja
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2016, 29 (03) : 277 - 283