Comparison of three methodologies for measuring intraocular pressure in healthy cats

被引:0
作者
Ricci, Claudia Lizandra [1 ]
Passareli, Joao Victor Goulart Consoni [1 ]
Nascimento, Felipe Franco [1 ]
Kanashiro, Glaucia Prada [1 ]
Zulim, Luis Felipe da Costa [1 ]
Giuffrida, Rogerio [1 ]
Andrade, Silvia Franco [1 ,2 ]
机构
[1] Univ Oeste Paulista, Postgrad Program Anim Sci, Presidente Prudente, SP, Brazil
[2] Univ Oeste Paulista, Vet Hosp, Dept Vet Ophthalmol, Presidente Prudente, SP, Brazil
关键词
applanation tonometry; goldmann tonometry; intraocular pressure; ocular manometry; rebound tonometry; TONOVET(R) REBOUND TONOMETER; TONO-PEN XL(R); APPLANATION TONOMETER; DOGS; CALIBRATION; GLAUCOMA;
D O I
10.14202/vetworld.2024.1803-1809
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Background and Aim: Measuring intraocular pressure (IOP) is crucial for identifying potentially damaging changes in the eyes, including diseases as glaucoma and uveitis. This study compared intraocular pressure (IOP) measurements in cats using the Tonovet and Tonovet Plus (rebound), Tono-Pen Avia Vet (applanation), and Kowa HA-2 (Goldman's methodology applanation) tonometers. Materials and Methods: 55 healthy cats (108 eyes) were assessed through three distinct studies: An ex vivo experiment (10 eyes of five cats) to correlate IOP manometry and tonometry values and ascertain the correlation coefficient (r2); an in vivo study (10 eyes of five sedated cats) to contrast manometer and tonometer readings; and an outpatient clinical trial (80 eyes of 45 cats) to analyze only tonometer measurements. Results: The r(2) values observed in the ex vivo study were Tonovet (0.923), Tonovet Plus (0.925), Tono-Pen Avia Vet (0.877), and Kowa HA-2 (0.901). The IOP values in mmHg in the in vivo study were as follows: Manometer (16.1 f 2.7), Tonovet (21.1 f 3.6), Tonovet Plus (19.7 f 7.2), Tono-Pen Avia Vet (17.6 f 7.9), and Kowa HA-2 (16.8 f 2.0). In the outpatient clinical study, the IOP values in mmHg were as follows: Tonovet (19.7 f 6.6), Tonovet Plus (17.1 f 5.4), Tono-Pen Avia Vet (16.3 f 4.3), and Kowa HA-2 (14.5 f 2.2). Conclusion: IOP and manometry readings were strongly correlated by all tonometers. In the clinical setting, the most and least IOP measurements were recorded using Tonovet and Kowa HA-2, respectively, stressing the importance of an IOP reference table for each tonometer in feline practice.
引用
收藏
页码:1803 / 1809
页数:7
相关论文
共 25 条
[1]   Comparison of intraocular pressure measurements between the Tono-Pen XL® and Perkins® applanation tonometers in dogs and cats [J].
Andrade, Silvia Franco ;
Palozzi, Rodrigo Jesus ;
Giuffrida, Rogerio ;
de Campos, Renata Juliane ;
Santos, Gabriela de Campos ;
Fukui, Rosimery Missuzu .
VETERINARY OPHTHALMOLOGY, 2012, 15 :14-20
[2]   Evaluation of the Perkins® handheld applanation tonometer in the measurement of intraocular pressure in dogs and cats [J].
Andrade, Silvia Franco ;
Cremonezi, Tatiana ;
Miranda Zachi, Cristiane Aparecida ;
Lonchiati, Caroline Ferreira ;
Amatuzzi, Juliana Dalarrosa ;
Sakamoto, Keila Priscilla ;
de Arruda Mello, Paulo Augusto .
VETERINARY OPHTHALMOLOGY, 2009, 12 (05) :277-284
[3]   Comparison of four tonometers in the measurement of intraocular pressure in healthy horses [J].
Angeluci, Gismelli C. ;
Ricci, Claudia L. ;
Passareli, Joao V. G. C. ;
Estanho, Giovana J. G. ;
Oliveira, Adriana S. ;
Santos, Stephany G. A. ;
Giuffrida, Rogerio ;
Rodrigues, Mirian ;
Andrade, Silvia F. .
EQUINE VETERINARY JOURNAL, 2023, 55 (06) :1104-1111
[4]   TonoVet Plus®: Higher reliability and repeatability compared with Tono-Pen XL™ and TonoVet® in rabbits [J].
Barbosa, Sirlene F. ;
Raposo, Ana Claudia S. ;
Dorea Neto, Francisco de Assis ;
Araujo, Nayone L. L. C. ;
Oliveira, Maria Madalena S. ;
Oria, Arianne P. .
VETERINARY OPHTHALMOLOGY, 2022, 25 (04) :272-281
[5]   Estimation of intraocular pressure in normal canine eyes utilizing the newly introduced TonoVet Plus and TonoPen Avia, and their comparison to the established TonoVet [J].
Ben-Shlomo, Gil ;
Muirhead, Sarah F. .
VETERINARY OPHTHALMOLOGY, 2021, 24 :171-174
[6]   Circadian rhythm of intraocular pressure in cats [J].
Del Sole, Maria J. ;
Sande, Pablo H. ;
Bernades, Jose M. ;
Aba, Marcelo A. ;
Rosenstein, Ruth E. .
VETERINARY OPHTHALMOLOGY, 2007, 10 (03) :155-161
[7]  
Ghaffari MS, 2018, J FELINE MED SURG, V20, P749, DOI [10.1177/1098612X17730706, 10.1177/1098612x17730706]
[8]   Feline Glaucoma [J].
Grahn, Bruce .
VETERINARY CLINICS OF NORTH AMERICA-SMALL ANIMAL PRACTICE, 2023, 53 (02) :367-387
[9]   CALIBRATION OF THE ALCON APPLANATION PNEUMATONOGRAPH AND PERKINS TONOMETER FOR USE IN RABBITS AND CATS [J].
HAMMOND, BR ;
BHATTACHERJEE, P .
CURRENT EYE RESEARCH, 1984, 3 (09) :1155-1158
[10]   Comparison of intraocular pressure in healthy brachycephalic and nonbrachycephalic cats using the Icare® TONOVET Plus rebound tonometer [J].
Kerdchuchuen, Kamolchanok ;
Samathayanon, Kingkarn ;
Phientong, Pitchapa ;
Chattraphirat, Suprapha ;
Jaturakan, Orapun ;
Tuntivanich, Nalinee .
VETERINARY OPHTHALMOLOGY, 2021, 24 (05) :484-490