Real-time monitoring of integrated continuous granulation/drying line system " LaVortex ®" for the pharmaceutical manufacturing of acetaminophen oral dosage formulations using near-infrared spectroscopy

被引:1
|
作者
Koyanagi, Keita [1 ]
Shoji, Kippei [2 ]
Ueno, Akinori [1 ]
Sasaki, Tetsuo [2 ,3 ,4 ]
Otsuka, Makoto [1 ,4 ]
机构
[1] Earthtech Corp Ltd, 1780 Kamikouya, Yachiyo, Chiba 2760022, Japan
[2] Shizuoka Univ, Grad Sch Integrated Sci & Technol, 3-5-1 Johoku,Cyuo ku, Hamamatsu, Shizuoka 4328011, Japan
[3] Shizuoka Univ, Grad Sch Med Photon, 3-5-1 Johoku,Cyuo ku, Hamamatsu, Shizuoka 4328011, Japan
[4] Shizuoka Univ, Res Inst Elect, 3-5-1 Johoku,Cyuo ku, Hamamatsu 4328011, Japan
关键词
Fully flow-type continuous manufacturing sys-; tem; Process analytical technology; Real-time-monitoring; Near-infrared spectroscopy; Acetaminophen; Partial least squares regression analysis; Critical quality attribute; Critical process parameter; WET-GRANULATION; HIGH-SHEAR; QUALITY; IMPELLER; FUTURE; DESIGN; BATCH;
D O I
10.1016/j.jddst.2024.106240
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Granules for tableting were continuously manufactured using a fully flow-type continuous wet-granulation and drying (CGD) line system, "LaVortex (R)." The raw material powder containing standard excipients and 28.8 % acetaminophen was mixed with a binder liquid (pure water), continuously wet-granulated, and dried for 600 s under 20 different granulation/drying process conditions, and the process was monitored in real-time using nearinfrared (NIR) spectroscopy. Twenty granulation/drying process conditions, varying across three parameters, namely added binding water rate, agitation blades and container rotational rates, and hot drying air flow rate, were applied. Training datasets from NIR spectroscopy stably measured during the CGD process were used to construct calibration models to predict the various critical quality attributes (CQAs) of granules, such as residual moisture content, median particle size, angle of repose, and tablet hardness, using partial least squares regression (PLSR). Optimal calibration models were validated using the NIR spectroscopy test dataset. The actual granule CQA profiles evaluated using the NIR/PLSR method were almost constant up to 600 s at the end of production depending on the critical process parameters (CPPs), except for fluctuations in the initial process. These results indicate that tableting granules with various pharmaceutical properties could be obtained continuously depending on CQAs, such as the rate of water addition. Additionally, changes in CQAs could be continuously monitored by the NIR/PLSR method. Furthermore, CGD granules with various characteristic CQAs can be continuously manufactured by controlling CPPs, such as agitation blades and tube rotation rates in the agitating granulation process and drying air flow rate in the drying process under NIR spectroscopy.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Real-time cortical adaptation monitoring system for prosthetic rehabilitation based on functional near-infrared spectroscopy
    Mizuochi, Chiaki
    Yabuki, Yoshiko
    Mouri, Yasuhiro
    Togo, Shunta
    Morishita, Soichiro
    Jiang, Yinlai
    Kato, Ryu
    Yokoi, Hiroshi
    2017 IEEE INTERNATIONAL CONFERENCE ON CYBORG AND BIONIC SYSTEMS (CBS), 2017, : 130 - 135
  • [22] Development of Inline Near-Infrared Spectroscopy Method for Real-Time Monitoring of Blend Uniformity of Direct Compression and Granulation-Based Products at Commercial Scales
    Khanolkar, Aruna
    Patil, Bhaskar
    Thorat, Viraj
    Samanta, Gautam
    AAPS PHARMSCITECH, 2022, 23 (07)
  • [23] The application of Near-Infrared Spatially Resolved Spectroscopy in scope of achieving continuous real-time quality monitoring and control of tablets with challenging dimensions
    De Man, A.
    Uyttersprot, J. -S.
    Chavez, P. -F.
    Vandenbroucke, F.
    Bovart, F.
    De Beer, T.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2023, 641
  • [24] Real-time Monitoring of Powder Blend Composition using Near Infrared Spectroscopy
    O'Mahony, Niall
    Murphy, Trevor
    Panduru, Krishna
    Riordan, Daniel
    Walsh, Joseph
    2017 ELEVENTH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2017, : 123 - 128
  • [25] Challenges, opportunities and recent advances in near infrared spectroscopy applications for monitoring blend uniformity in the continuous manufacturing of solid oral dosage forms
    Velez, Natasha L.
    Drennen, James K.
    Anderson, Carl A.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2022, 615
  • [26] Effect of Sampling Frequency for Real-Time Tablet Coating Monitoring Using Near Infrared Spectroscopy
    Igne, Benoit
    Arai, Hiroaki
    Drennen, James K.
    Anderson, Carl A.
    APPLIED SPECTROSCOPY, 2016, 70 (09) : 1476 - 1488
  • [27] A process monitoring microreactor assembly for real-time reaction analysis using inline near-infrared spectroscopy and chemometrics
    Mahler, Lukas
    Desel, Pascal
    Sladkov, Marcel
    Roppertz, Andreas
    Mayer, Christian
    Jaeger, Martin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2025, 417 (08) : 1431 - 1439
  • [28] Real-time determination of critical quality attributes using near-infrared spectroscopy: A contribution for Process Analytical Technology (PAT)
    Rosas, Juan G.
    Blanco, Marcel
    Gonzalez, Josep M.
    Alcala, Mane
    TALANTA, 2012, 97 : 163 - 170
  • [29] Process modeling and control applied to real-time monitoring of distillation processes by near-infrared spectroscopy
    de Oliveira, Rodrigo R.
    Pedroza, Ricardo H. P.
    Sousa, A. O.
    Lima, Kassio M. G.
    de Juan, Anna
    ANALYTICA CHIMICA ACTA, 2017, 985 : 41 - 53
  • [30] Towards real-time release of pharmaceutical tablets: 100% in-line control via near-infrared spatially resolved spectroscopy and 3D microwave resonance technology
    Brouckaert, Davinia
    Vandenbroucke, Freddy
    Chauchard, Fabien
    Dollinger, Martial
    Roggo, Yves
    Pellegatti, Laurent
    Krumme, Markus
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 209