Virtual simulation for flow-diverter selection and sizing in the endovascular treatment of intracranial aneurysms: A systematic review and meta-analysis

被引:0
|
作者
Ferreira, Christian [1 ]
Ferreira, Marcio Yuri [1 ]
Bertani, Raphael [2 ]
Palavani, Lucca Biolcati [3 ]
Borges, Pedro G. L. B. [4 ]
Gunkan, Ahmet [5 ]
Mueller, Gean Carlo [6 ]
Maia, Henrique Garcia [7 ]
Semione, Gabriel [8 ]
Batista, Savio [9 ]
Lepine, Henrique Laurent [2 ]
Zumofen, Daniel [10 ]
Stark, Katherine [1 ]
Hanel, Ricardo A. [11 ]
Gordon, David [12 ]
Serulle, Yafell [1 ]
Langer, David [1 ]
机构
[1] LENOX HILL HOSP, Dept Neurosurg, NEW YORK, NY USA
[2] Univ Sao Paulo, Dept Neurosurg, Sao Paulo, Brazil
[3] Max Planck Univ Ctr, Fac Med, Indaiatuba, Brazil
[4] Fundacao Tecn Educ Souza Marques, Rio De Janeiro, Brazil
[5] Faith Sultan Mehmet Training & Res Hosp, Dept Radiol, Istanbul, Turkiye
[6] Univ Caxias Do Sul, Fac Med, Caxias Do Sul, Brazil
[7] Estacio Sa Univ Citta IDOMED, Fac Med, Gastao Senges Ave 125, BR-22631280 Rio De Janeiro, Brazil
[8] Univ West Santa Catarina, Joacaba, Brazil
[9] Univ Fed Rio de Janeiro, Rio De Janeiro, Brazil
[10] Maimonides Hosp, Div Neurosurg, Brooklyn, NY USA
[11] Baptist Med Ctr Jacksonville, Dept Neurosurg, Jacksonville, FL USA
[12] Northern Westchester & Phelps Hosp, Hofstra Northwell Sch Med, Westchester, NY USA
关键词
Flow-diverter; simulation; flow-diverter sizing; OCCLUSION; DEVICE; SIZE;
D O I
10.1177/15910199251323006
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Endovascular treatment (EVT) of intracranial aneurysms (IAs) has improved significantly with the integration of virtual simulation software (VSS) in surgical planning and device selection. Despite promising outcomes, discrepancies remain between physician and VSS recommendations. This review synthesizes evidence on (1) comparisons between VSS-chosen and physician-chosen dimensions; (2) VSS-chosen and postoperative measured dimensions; and (3) the success rate of VSS-guided device deployment. Methods A systematic search adhering to PRISMA guidelines was conducted in Medline, Embase, Web of Science, and Cochrane databases up to January 2024. Eligible studies included case series, cohort studies, and randomized trials assessing VSS for stent selection in IAs treatment. Mean difference (MD) and single-arm meta-analysis with 95% confidence intervals (CIs) under a random-effects model were performed for continuous and binary outcomes. Subanalyses were conducted for Sim&Size and PreSize software. Results Ten studies comprising 658 IAs were included. Pipeline Embolization Device was most commonly used. Findings demonstrated (1) high accuracy of VSS when comparing simulated and postoperative lengths (MD -1.7 mm; 95% CI -4.37 to 0.98 mm); (2) physician-chosen lengths overestimated compared to VSS (MD -2.11 mm; -3.43 to -0.79 mm); (3) no significant difference in physician- versus VSS-chosen diameters (MD -0.04 mm; -0.13 to 0.06 mm); and (4) high VSS-guided deployment success (96%; 93-99%) with low complications (4%). Subanalyses showed 95% and 92% deployment success rates for Sim&Size and PreSize, respectively. Conclusion VSS effectively estimates device length and achieves high deployment success, with low complication rates, supporting its utility in EVT planning.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Efficacy and safety of flow diverters in retreatment of recurrent intracranial aneurysms-A systematic review and meta-analysis
    Zarrintan, Armin
    Ghozy, Sherief
    Maroufi, Seyed Farzad
    Reda, Abdullah
    Brinjikji, Waleed
    Kadirvel, Ramanathan
    Kallmes, David F.
    INTERVENTIONAL NEURORADIOLOGY, 2024,
  • [32] SILK flow diverter for treatment of intracranial aneurysms: initial experience and cost analysis
    Shankar, Jai Jai Shiva
    Vandorpe, Robert
    Pickett, Gwynedd
    Maloney, William
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2013, 5 : III11 - III15
  • [33] Endovascular outcomes for anterior choroidal artery aneurysms: systematic review and meta-analysis
    Senol, Yigit Can
    Orscelik, Atakan
    Musmar, Basel
    Ghozy, Sherief
    Bilgin, Gokce Belge
    Kobeissi, Hassan
    Pakkam, Madona
    Kallmes, David F.
    Kadirvel, Ramanathan
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2024, 33 (06)
  • [34] Treatment of ruptured intracranial aneurysms using the novel generation of flow-diverters with surface modification: A systematic review and meta-analysis
    Monteiro, Andre
    Khan, Asham
    Donnelly, Brianna M.
    Kuo, Cathleen C.
    Burke, Samantha M.
    Waqas, Muhammad
    Housley, Steven B.
    Cappuzzo, Justin M.
    Davies, Jason M.
    Snyder, Kenneth, V
    Levy, Elad, I
    Siddiqui, Adnan H.
    INTERVENTIONAL NEURORADIOLOGY, 2024, 30 (03) : 350 - 360
  • [35] Endovascular treatment of intracranial vertebrobasilar artery dissecting aneurysms: Parent artery occlusion versus flow diverter
    Fang, Yi-Bin
    Lin, Amy
    Kostynskyy, Alex
    Agid, Ronit
    Tymianski, Mike
    Radovanovic, Ivan
    Krings, Timo
    Pereira, Vitor Mendes
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 99 : 68 - 75
  • [36] Safety and Efficacy of Flow Diverter Treatment for Blood Blister-Like Aneurysm: A Systematic Review and Meta-Analysis
    Zhu, Deyuan
    Yan, Yazhou
    Zhao, Puyuan
    Duan, Guoli
    Zhao, Rui
    Liu, Jianmin
    Huang, Qinghai
    WORLD NEUROSURGERY, 2018, 118 : E79 - E86
  • [37] Letter by Lanterna et al Regarding Article, "Endovascular Treatment of Intracranial Aneurysms With Flow-Diverters, A Meta-Analysis"
    Lanterna, Luigi A.
    Gritti, Paolo
    Biroli, Francesco
    STROKE, 2013, 44 (05) : E54 - E54
  • [38] Endovascular treatment of intracranial aneurysms with the p64 flow diverter stent: mid-term results in 35 patients with 41 intracranial aneurysms
    Ricardo Morais
    Benjamin Mine
    Pierre Julien Bruyère
    Gilles Naeije
    Boris Lubicz
    Neuroradiology, 2017, 59 : 263 - 269
  • [39] Towards Predicting Patient-Specific Flow-Diverter Treatment Outcomes for Bifurcation Aneurysms: From Implantation Rehearsal to Virtual Angiograms
    Peach, T. W.
    Spranger, K.
    Ventikos, Y.
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (01) : 99 - 111
  • [40] Towards Predicting Patient-Specific Flow-Diverter Treatment Outcomes for Bifurcation Aneurysms: From Implantation Rehearsal to Virtual Angiograms
    T. W. Peach
    K. Spranger
    Y. Ventikos
    Annals of Biomedical Engineering, 2016, 44 : 99 - 111