Virtual simulation for flow-diverter selection and sizing in the endovascular treatment of intracranial aneurysms: A systematic review and meta-analysis

被引:0
|
作者
Ferreira, Christian [1 ]
Ferreira, Marcio Yuri [1 ]
Bertani, Raphael [2 ]
Palavani, Lucca Biolcati [3 ]
Borges, Pedro G. L. B. [4 ]
Gunkan, Ahmet [5 ]
Mueller, Gean Carlo [6 ]
Maia, Henrique Garcia [7 ]
Semione, Gabriel [8 ]
Batista, Savio [9 ]
Lepine, Henrique Laurent [2 ]
Zumofen, Daniel [10 ]
Stark, Katherine [1 ]
Hanel, Ricardo A. [11 ]
Gordon, David [12 ]
Serulle, Yafell [1 ]
Langer, David [1 ]
机构
[1] LENOX HILL HOSP, Dept Neurosurg, NEW YORK, NY USA
[2] Univ Sao Paulo, Dept Neurosurg, Sao Paulo, Brazil
[3] Max Planck Univ Ctr, Fac Med, Indaiatuba, Brazil
[4] Fundacao Tecn Educ Souza Marques, Rio De Janeiro, Brazil
[5] Faith Sultan Mehmet Training & Res Hosp, Dept Radiol, Istanbul, Turkiye
[6] Univ Caxias Do Sul, Fac Med, Caxias Do Sul, Brazil
[7] Estacio Sa Univ Citta IDOMED, Fac Med, Gastao Senges Ave 125, BR-22631280 Rio De Janeiro, Brazil
[8] Univ West Santa Catarina, Joacaba, Brazil
[9] Univ Fed Rio de Janeiro, Rio De Janeiro, Brazil
[10] Maimonides Hosp, Div Neurosurg, Brooklyn, NY USA
[11] Baptist Med Ctr Jacksonville, Dept Neurosurg, Jacksonville, FL USA
[12] Northern Westchester & Phelps Hosp, Hofstra Northwell Sch Med, Westchester, NY USA
关键词
Flow-diverter; simulation; flow-diverter sizing; OCCLUSION; DEVICE; SIZE;
D O I
10.1177/15910199251323006
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Endovascular treatment (EVT) of intracranial aneurysms (IAs) has improved significantly with the integration of virtual simulation software (VSS) in surgical planning and device selection. Despite promising outcomes, discrepancies remain between physician and VSS recommendations. This review synthesizes evidence on (1) comparisons between VSS-chosen and physician-chosen dimensions; (2) VSS-chosen and postoperative measured dimensions; and (3) the success rate of VSS-guided device deployment. Methods A systematic search adhering to PRISMA guidelines was conducted in Medline, Embase, Web of Science, and Cochrane databases up to January 2024. Eligible studies included case series, cohort studies, and randomized trials assessing VSS for stent selection in IAs treatment. Mean difference (MD) and single-arm meta-analysis with 95% confidence intervals (CIs) under a random-effects model were performed for continuous and binary outcomes. Subanalyses were conducted for Sim&Size and PreSize software. Results Ten studies comprising 658 IAs were included. Pipeline Embolization Device was most commonly used. Findings demonstrated (1) high accuracy of VSS when comparing simulated and postoperative lengths (MD -1.7 mm; 95% CI -4.37 to 0.98 mm); (2) physician-chosen lengths overestimated compared to VSS (MD -2.11 mm; -3.43 to -0.79 mm); (3) no significant difference in physician- versus VSS-chosen diameters (MD -0.04 mm; -0.13 to 0.06 mm); and (4) high VSS-guided deployment success (96%; 93-99%) with low complications (4%). Subanalyses showed 95% and 92% deployment success rates for Sim&Size and PreSize, respectively. Conclusion VSS effectively estimates device length and achieves high deployment success, with low complication rates, supporting its utility in EVT planning.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Endovascular treatment of complex intracranial aneurysms by pipeline flow-diverter embolization device: a single-center experience
    Keskin, Fatih
    Erdi, Fatih
    Kaya, Bulent
    Poyraz, Necdet
    Keskin, Suat
    Kalkan, Erdal
    Ozbek, Orhan
    Koc, Osman
    NEUROLOGICAL RESEARCH, 2015, 37 (04) : 359 - 365
  • [12] Flow diverter retreatment for intracranial aneurysms: A meta-analysis of efficacy and feasibility
    Lee, Irene
    Kao, Yung-Shuo
    Lai, Yen-Jun
    Yen, Ho-Hsian
    INTERVENTIONAL NEURORADIOLOGY, 2024, 30 (01) : 37 - 42
  • [13] Periprocedural complications of second-generation flow diverter treatment using Pipeline Flex for unruptured intracranial aneurysms: a systematic review and meta-analysis
    Bhatia, Kartik Dev
    Kortman, Hans
    Orru, Emanuele
    Klostranec, Jesse M.
    Pereira, Vitor M.
    Krings, Timo
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (08) : 817 - 824
  • [14] Pipeline versus non-pipeline flow diverter treatment for M1 aneurysms: A systematic review and meta-analysis
    Senol, Yigit Can
    Orscelik, Atakan
    Bilgin, Cem
    Kobeissi, Hassan
    Ghozy, Sherief
    Arul, Santhosh
    Kallmes, David F.
    Kadirvel, Ramanathan
    NEURORADIOLOGY JOURNAL, 2025, 38 (02) : 133 - 141
  • [15] Safety and efficacy of low profile flow diverter stents for intracranial aneurysms in small parent vessels: systematic review and meta-analysis
    Elek, Alperen
    Karagoz, Sidar
    Dindar, Gulfem Nur
    Yucel, Semra
    Cinar, Celal
    Kusbeci, Mahmut
    Ozturk, Egemen
    Oran, Ismail
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2025,
  • [16] A systematic review and meta-analysis of the Derivo Embolization Device: a novel surface-modified flow diverter for intracranial aneurysm treatment
    Monteiro, Andre
    Burke, Samantha M.
    Baig, Ammad A.
    Khan, Slah
    Cappuzzo, Justin M.
    Waqas, Muhammad
    Dietrich, Joseph E.
    Levy, Elad, I
    Siddiqui, Adnan H.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2022, 14 (11) : 1125 - 1129
  • [17] Pipeline Vantage Embolization Device for the treatment of intracranial aneurysms: A systematic review and meta-analysis
    Goertz, Lukas
    Hohenstatt, Sophia
    Zopfs, David
    Kottlors, Jonathan
    Pennig, Lenhard
    Schlamann, Marc
    Michael, Arwed Elias
    Liebig, Thomas
    Moehlenbruch, Markus A.
    Kabbasch, Christoph
    INTERVENTIONAL NEURORADIOLOGY, 2024,
  • [18] Single antiplatelet regimen in flow diverter treatment of cerebral aneurysms: The drug matters. A systematic review and meta-analysis
    Ma, Yihui
    Madjidyar, Jawid
    Schubert, Tilman
    Thurner, Patrick
    Barnaure, Isabelle
    Kulcsar, Zsolt
    INTERVENTIONAL NEURORADIOLOGY, 2023,
  • [19] The Woven EndoBridge (WEB) for endovascular therapy of intracranial aneurysms: Update of a systematic review with meta-analysis
    Tau, Noam
    Sadeh-Gonik, Udi
    Aulagner, Gilles
    Turjman, Francis
    Gory, Benjamin
    Armoiry, Xavier
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2018, 166 : 110 - 115
  • [20] Flow diverter for endovascular treatment of intracranial mirror segment internal carotid artery aneurysms
    Kuhn, Anna Luisa
    Kan, Peter
    Srinivasan, Visish
    Rex, David E.
    Rodrigues, Katyucia de Macedo
    Howk, Mary C.
    Wakhloo, Ajay K.
    Puri, Ajit S.
    INTERVENTIONAL NEURORADIOLOGY, 2019, 25 (01) : 4 - 11