Minimum Local Anesthetic Dose of Ropivacaine in Cesarean Section for Real-Time Ultrasound-Guided Spinal Anesthesia Using 24-Gauge versus 26-Gauge Needles Based on Fluid Simulation Technology: A Randomized Controlled Trial

被引:0
作者
Zheng, Chunying [1 ]
Fan, Hanliang [1 ]
Ye, Peng [1 ]
Zhang, Xing [1 ]
Zheng, Xiaochun [1 ,2 ]
Zheng, Ting [1 ]
机构
[1] Fuzhou Univ, Fujian Med Univ, Affiliated Prov Hosp,Fujian Prov Hosp, Dept Anesthesiol,Shengli Clin Med Coll, Fuzhou, Peoples R China
[2] Fujian Emergency Med Ctr, Fujian Prov Key Lab Emergency Med, Fujian Prov Key Lab Crit Care Med, Fujian Prov Coconstructed Lab Belt & Rd, Fuzhou, Peoples R China
来源
DRUG DESIGN DEVELOPMENT AND THERAPY | 2024年 / 18卷
关键词
anesthetic diffusion; spinal needle diameter; fluid dynamics simulation; cesarean anesthetization; PLAIN BUPIVACAINE; FLOW; DELIVERY; PUNCTURE; ED50;
D O I
10.2147/DDDT.S476710
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Purpose: Previous research has demonstrated that real-time ultrasound-guided (UG) spinal anesthesia requires a higher minimum local anesthetic dose (MLAD) compared to traditional methods. However, the precise MLAD of ropivacaine for UG cesarean sections remains undetermined. In this study, we ascertained the MLAD of ropivacaine for cesarean section. We also investigated the mechanism underlying the diffusion of ropivacaine within the spinal canal using fluid simulation technology. Patients and Methods: We randomly placed 60 healthy parturients undergoing elective cesarean section with real-time UG spinal anesthesia into Groups I (26-gauge spinal needle) and II (24-gauge spinal needle). For the first parturient in both groups, 15 mg of ropivacaine was administered intrathecally. Based on the effective or ineffective response of the previous parturient, the dose for the subsequent parturient was increased or decreased by 1 mg. Spinal anesthesia characteristics and side effects were recorded. A computer-generated spinal canal model was developed. Leveraging fluid dynamics simulation technology, we documented the diffusion of ropivacaine in the spinal canal using 26-and 24-gauge spinal needles. Results: The MLADs in Groups I and II were 12.728 mg (12.339-13.130 mg) and 9.795 mg (9.491-10.110 mg), respectively. No significant difference was observed in the onset times and durations of sensory or motor blocks, incidence of complications, or neonatal Apgar scores between both groups. Fluid simulation modeling indicated that the 26-gauge spinal needle achieved a higher distribution level more quickly; however, its peak drug concentration was lower compared to the 24-gauge spinal needle. Conclusion: For cesarean section anesthetization, the required MLAD of ropivacaine when using a real-time UG 26-gauge spinal needle is significantly greater than that with a 24-gauge needle. The spinal needle diameter influences ropivacaine's MLAD by markedly affecting its diffusion rate within the spinal canal.
引用
收藏
页码:4401 / 4412
页数:12
相关论文
共 37 条
  • [1] Practice Guidelines for Obstetric Anesthesia An Updated Report by the American Society of Anesthesiologists Task Force on Obstetric Anesthesia and the Society for Obstetric Anesthesia and Perinatology
    Apfelbaum J.L.
    Hawkins J.L.
    Agarkar M.
    Bucklin B.A.
    Connis R.T.
    Gambling D.R.
    Mhyre J.
    Nickinovich D.G.
    Sherman H.
    Tsen L.C.
    Yaghmour E.T.A.
    [J]. ANESTHESIOLOGY, 2016, 124 (02) : 270 - 300
  • [2] Trends and projections of caesarean section rates: global and regional estimates
    Betran, Ana Pilar
    Ye, Jiangfeng
    Moller, Ann-Beth
    Souza, Joao Paulo
    Zhang, Jun
    [J]. BMJ GLOBAL HEALTH, 2021, 6 (06):
  • [3] Hyperbaric prilocaine vs. hyperbaric bupivacaine for spinal anaesthesia in women undergoing elective caesarean section: a comparative randomised double-blind study
    Chapron, K.
    Sleth, J. -C.
    Capdevila, X.
    Bringuier, S.
    Dadure, C.
    [J]. ANAESTHESIA, 2021, 76 (06) : 777 - 784
  • [4] Intrathecal sufentanil decreases the median effective dose (ED50) of intrathecal hyperbaric ropivacaine for caesarean delivery
    Chen, X.
    Qian, X.
    Fu, F.
    Lu, H.
    Bein, B.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2010, 54 (03) : 284 - 290
  • [5] The presence of arachnoiditis affects the characteristics of CSF flow in the spinal subarachnoid space: A modelling study
    Cheng, Shaokoon
    Stoodley, Marcus A.
    Wong, Johnny
    Hemley, Sarah
    Fletcher, David F.
    Bilston, Lynne E.
    [J]. JOURNAL OF BIOMECHANICS, 2012, 45 (07) : 1186 - 1191
  • [6] Ultrasonography of the Adult Thoracic and Lumbar Spine for Central Neuraxial Blockade
    Chin, Ki Jinn
    Karmakar, Manoj Kumar
    Peng, Philip
    [J]. ANESTHESIOLOGY, 2011, 114 (06) : 1459 - 1485
  • [7] Real-time ultrasound-guided paramedian spinal anaesthesia: evaluation of the efficacy and the success rate of single needle pass
    Chong, S. E.
    Nikman, A. Mohd
    Saedah, A.
    Nazaruddin, W. H. Wan Mohd
    Kueh, Y. C.
    Lim, J. A.
    Kamalrujan, H. Shamsul
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2017, 118 (05) : 799 - 801
  • [8] Comparing spinal blockade effectiveness and maternal hemodynamics using 25 gauge and 29 gauge spinal needles with the same volumetric flow rate in patients undergoing caesarean section
    Ciftci, Taner
    Daskaya, Hayrettin
    Efe, Serdar
    [J]. JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 37 (06) : 719 - 722
  • [9] Computational fluid dynamics modelling of cerebrospinal fluid pressure in Chiari malformation and syringomyelia
    Clarke, Elizabeth C.
    Fletcher, David F.
    Stoodley, Marcus A.
    Bilston, Lynne E.
    [J]. JOURNAL OF BIOMECHANICS, 2013, 46 (11) : 1801 - 1809
  • [10] Obesity in Pregnancy
    Creanga, Andreea A.
    Catalano, Patrick M.
    Bateman, Brian T.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2022, 387 (03) : 248 - 259