Comparison of Proton Versus Photon SBRT for Treatment of Spinal Metastases Using Variable RBE Models

被引:0
|
作者
Shaaban, Sherif G. [1 ]
Lecompte, Michael
Chen, Hao [1 ]
Lubelski, Daniel [2 ]
Bydon, Ali [2 ]
Theodore, Nicholas [2 ]
Khan, Majid [3 ]
Lee, Sang
Kebaish, Khaled [4 ]
Kleinberg, Lawrence [1 ]
Hooker, Ted [1 ]
Li, Heng [1 ]
Redmond, Kristin J. [1 ]
机构
[1] Johns Hopkins Univ, Radiat Oncol & Mol Radiat Sci, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Neurosurg, Baltimore, MD USA
[3] Johns Hopkins Univ, Radiol & Radiol Sci, Baltimore, MD USA
[4] Johns Hopkins Univ, Orthoped Surg, Baltimore, MD USA
关键词
Proton spine SBRT; Photon spine SBRT; Spine metastasis; RBE-weighted dose; RELATIVE BIOLOGICAL EFFECTIVENESS; STEREOTACTIC BODY RADIOTHERAPY; LOW-DOSE HYPERSENSITIVITY; CARBON ION RADIOTHERAPY; LOW-ENERGY PROTONS; RADIATION-THERAPY; V79; CELLS; BEAM THERAPY; PROSTATE; SURVIVAL;
D O I
10.1016/j.ijpt.2025.100743
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
largely due to concerns of increased risk of spinal cord injury given the challenges of end of range relative biological effectiveness (RBE). Although the 1.1 RBE constant for proton beam has been adopted for clinical use, data indicate that proton RBE is variable and dependent on technical-, tissue-, and patient factors. To better understand the safety of proton SBRT for spinal metastasis, this dosimetric analysis compares plans using photon robotic techniques and proton therapy accounting for RBE-weighted dose (D_{RBE}). Materials and Methods: Nine patients with spinal metastasis were selected to be representative of a broad range of complex clinical practice (3 cervical, 3 thoracic, 3 lumbar) that are uniquely challenging to treat with SBRT were identified. Each vertebral level contained a case with paraspinal extension, a reirradiation case, and a case with high-grade epidural disease (Bilsky grade >= 1c) given that such complex cases in current practice often require target volume under-coverage with photon SBRT (PH-SBRT) in order to meet organ at risk (OAR) dose constraints. All selected patients were treated with PH-SBRT using a robotic system to a prescription dose of 30 Gy in 5 fractions despite our institutional preference for further dose escalation, because further dose escalation was not feasible in the original planning process while keeping normal tissues below acceptable dose constraints. To see if superior target coverage could be achieved with proton treatment, comparative intensity modulated proton therapy (IMPT) plans were generated with the same prescription dose as what was clinically delivered using the 1.1 RBE constant. Dose escalated IMPT plans were then generated to 45 Gy(RBE) in 5 fractions. Variable RBE models (Carabe, McNamara, and Wedenberg) were then utilized to generate RBE-weighted dose D_{RBE} distribution for 30 Gy(RBE) and 45 Gy(RBE) plans using the alpha/beta value (which was 3.76 in this study), physical dose, linear energy transfer (LET) value, and dose per fraction parameters. Proton plans used the robust optimization parameters of +/- 3.5% range and 2-mm setup uncertainties. Planning target volume (PTV) coverage and OARs sparing were compared using the Wilcoxon signed-rank test. Results: Planning target volume coverage was significantly improved when comparing PH-SBRT at 30 Gy in 5 fractions (median: 25 Gy) to IMPT at 30 Gy[RBE] in 5 fractions (median: 30.3 Gy[RBE], P = .02) and 45 Gy (RBE) in 5 fractions (median 35.6 Gy[RBE], P = .001). Maximum dose of the spinal cord (cord Dmax) was significantly lower with IMPT at 30 Gy(RBE) (median: 17.6 Gy[RBE], P = .04) and 45 Gy(RBE) (median: 16.1 Gy[RBE], P = .04) compared to conventional plan at 30 Gy (median: 18 Gy). Spinal cord expansion (cord + 2 mm) maximum dose did not change in both photon (median 21.5 Gy) and proton plans (median 22.5, P = .27). Other OARs were better spared with the same and dose-escalated proton plans. No difference was seen in cord Dmax when comparing the PH-SBRT at 30 Gy to D_{RBE} at 30 and 45 Gy(RBE) using Carabe-, McNamara-, or Wedenberg models. However, for spinal cord expansion (cord + 2 mm), there was significant difference between PH-SBRT and D_{RBE} at 30 Gy(RBE) and 45 Gy(RBE) in 5 fractions using Carabe- (median: 25.4 Gy[RBE], P = .002), McNamara- (median: 25.1 Gy[RBE], P = .003), or Wedenberg (median: 24.8 Gy [RBE], P = .0001) models. The average increase in the spinal cord expansion maximum dose using these models compared to the fixed RBE plans was 5.3%. Conclusion: We report the first dosimetric analysis of proton SBRT for spine metastasis using variable RBE dose models. Compared to photon SBRT, IMPT may provide improved target coverage and better spare adjacent OARs, though fixed RBE models can underestimate the maximum dose to adjacent OARs. Future prospective studies are needed to validate these results.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Inclusion of a variable RBE into proton and photon plan comparison for various fractionation schedules in prostate radiation therapy
    Oden, Jakob
    Eriksson, Kjell
    Toma-Dasu, Iuliana
    MEDICAL PHYSICS, 2017, 44 (03) : 810 - 822
  • [2] Fixed- versus Variable-RBE Computations for Intensity Modulated Proton Therapy
    Yepes, Pablo
    Adair, Antony
    Frank, Steven J.
    Grosshans, David R.
    Liao, Zhongxing
    Liu, Amy
    Mirkovic, Dragan
    Poenisch, Falk
    Titt, Uwe
    Wang, Qianxia
    Mohan, Radhe
    ADVANCES IN RADIATION ONCOLOGY, 2019, 4 (01) : 156 - 167
  • [3] Comparison of SBRT and RFA in the Treatment of Intrahepatic Metastases
    Slovak, Ryan
    Lu, David S.
    Raja, Junaid
    Arellano, Ronald S.
    Kim, Hyun S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 104 (03): : 695 - 696
  • [4] Quantification of the uncertainties of a biological model and their impact on variable RBE proton treatment plan optimization
    Resch, A. F.
    Landry, G.
    Kamp, F.
    Cabal, G.
    Belka, C.
    Wilkens, J. J.
    Parodi, K.
    Dedes, G.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 36 : 91 - 102
  • [5] Comparison of VMAT and IMRT plans for SBRT treatment of multiple liver metastases using a single isocenter
    Zhu, L.
    Lu, X.
    Wang, A. H.
    Xiang, Z. L.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2023, 21 (02): : 189 - 194
  • [6] Dosimetric Comparison of Proton Versus Photon Radiosurgery for Treatment of Pituitary Adenoma
    Sud, Shivani
    Botticello, Thomas
    Niemierko, Andrzej
    Daly, Jillian
    Bussiere, Marc
    Shih, Helen A.
    ADVANCES IN RADIATION ONCOLOGY, 2021, 6 (06)
  • [7] 'Dirty dose'-based proton variable RBE models - performance assessment on in vitro data
    Kalholm, Fredrik
    Toma-Dasu, Iuliana
    Traneus, Erik
    MEDICAL PHYSICS, 2025, 52 (02) : 1311 - 1322
  • [8] Applying a variable relative biological effectiveness (RBE) might affect the analysis of clinical trials comparing photon and proton therapy for prostate cancer
    Marteinsdottir, Maria
    Paganetti, Harald
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (11)
  • [9] SBRT of Spinal Metastases Using a Simultaneous Integrated Boost Concept in Oligometastatic Cancer Patients Is Safe and Effective
    Waltenberger, Maria
    Strick, Christian
    Vogel, Marco M. E.
    Diehl, Christian
    Combs, Stephanie E.
    CANCERS, 2023, 15 (24)
  • [10] Comparing photon and proton-based hypofractioned SBRT for prostate cancer accounting for robustness and realistic treatment deliverability
    Goddard, Lee C.
    Brodin, N. Patrik
    Bodner, William R.
    Garg, Madhur K.
    Tome, Wolfgang A.
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1085)