Reconstructing a Dilution Refrigerator for use in Low Energy Nuclear Experiments

被引:0
|
作者
Roberts, Matthew [1 ]
Norum, Blaine [1 ]
Crabb, Donald [1 ]
Keller, Dustin [1 ]
机构
[1] Univ Virginia, 382 McCormick Rd, Charlottesville, VA 22903 USA
关键词
D O I
暂无
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The Gerasimov-Drell-Hearn (GDH) sum rule states that the difference between the parallel and antiparallel cross sections of a circularly polarized photon hitting a longitudinally polarized target is proportional to the square of the anomalous magnetic moment of the target. We plan to use the GDH sum rule to study the nuclear structure of the deuteron. To do that, we put our target material into a Frozen Spin setup, made possible by a dilution refrigerator originally constructed at CERN in the 1970s. However, when a leak was discovered in a critical part of the dilution unit, we had to remove it. This talk will discuss the reconstruction of this dilution unit, what still needs to be done, and how the experiment will be run.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] DILUTION REFRIGERATOR FOR LOW-TEMPERATURE NUCLEAR ORIENTATION EXPERIMENTS ON LINE TO AN ISOTOPE SEPARATOR
    HERZOG, P
    FOLLE, HR
    FREITAG, K
    KLUGE, A
    REUSCHENBACH, M
    BODENSTEDT, E
    NUCLEAR INSTRUMENTS & METHODS, 1978, 155 (03): : 421 - 428
  • [2] A HIGH-POWER, LOW HEAT LEAK DILUTION REFRIGERATOR FOR USE WITH NUCLEAR COOLING
    BRADLEY, DI
    BRADSHAW, TW
    GUENAULT, AM
    KEITH, V
    LOCKESCOBIE, BG
    MILLER, IE
    PICKETT, GR
    PRATT, WP
    PHYSICA B & C, 1981, 107 (1-3): : 561 - 562
  • [3] Development of a dilution refrigerator for low-temperature microgravity experiments
    Roach, PR
    Helvensteijn, BPM
    CRYOCOOLERS 10, 1999, : 647 - 653
  • [4] A LOW-TEMPERATURE NMR PROBE FOR USE IN A DILUTION REFRIGERATOR
    KUHNS, PL
    LEE, SH
    CORETSOPOULOS, C
    HAMMEL, PC
    GONEN, O
    WAUGH, JS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (09): : 2159 - 2162
  • [5] A DILUTION REFRIGERATOR COMBINING LOW BASE TEMPERATURE, HIGH COOLING POWER AND LOW HEAT LEAK FOR USE WITH NUCLEAR COOLING
    BRADLEY, DI
    BRADSHAW, TW
    GUENAULT, AM
    KEITH, V
    LOCKESCOBIE, BG
    MILLER, IE
    PICKETT, GR
    PRATT, WP
    CRYOGENICS, 1982, 22 (06) : 296 - 304
  • [6] A LARGE DILUTION REFRIGERATOR FOR POLARIZED TARGET EXPERIMENTS
    BERGLUND, P
    KYYNARAINEN, J
    NIINIKOSKI, TO
    CRYOGENICS, 1994, 34 : 235 - 238
  • [7] LOW-NOISE FRONT-END ELECTRONICS FOR DILUTION REFRIGERATOR EXPERIMENTS
    STOCKWELL, W
    YVON, D
    AUBOURG, E
    BARNES, PD
    CUMMINGS, A
    DASILVA, A
    ELLMAN, B
    ROSS, RR
    SADOULET, B
    SHUTT, T
    SMITH, G
    STUBBS, C
    WANG, N
    WHITE, S
    YOUNG, BA
    JOURNAL OF LOW TEMPERATURE PHYSICS, 1993, 93 (3-4) : 755 - 760
  • [8] DILUTION REFRIGERATOR FOR MUON SPIN RELAXATION EXPERIMENTS
    COOKE, DW
    HOFFER, JK
    MAEZ, M
    STEYERT, WA
    HEFFNER, RH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (03): : 336 - 340
  • [9] HE-3-HE-4 DILUTION REFRIGERATOR CRYOSTAT SYSTEM FOR NUCLEAR ORIENTATION EXPERIMENTS
    BECKER, AJ
    HENRIKSON, HE
    COOK, DC
    NUCLEAR INSTRUMENTS & METHODS, 1973, 108 (02): : 291 - 296
  • [10] INSTALLATION OF 4-K REFRIGERATOR IN DILUTION REFRIGERATOR WITH NUCLEAR DEMAGNETIZATION APPARATUS
    MATSUMOTO, K
    OKUDA, Y
    CRYOGENICS, 1993, 33 (11) : 1018 - 1022