Prevention of Air Embolism in Extracorporeal Membrane Oxygenation Systems: An In Vitro Study on Protection of Central Venous Catheter Lumen

被引:0
作者
Franco, Danilo [1 ,2 ,3 ,4 ]
Krasna, Nejc [5 ]
Novak, Robert [6 ]
Esposito, Giovanni [2 ]
Izzo, Raffaele [2 ]
Belohlavek, Jan [3 ,4 ]
Noc, Marko [1 ,7 ]
Goslar, Tomaz [1 ,7 ]
机构
[1] Univ Med Ctr, Ctr Intens Internal Med, Zaloska 7, Ljubljana 1000, Slovenia
[2] Univ Naples Federico II, Dept Adv Biomed Sci, Via Pansini 5, I-80131 Naples, Italy
[3] Charles Univ Prague, Fac Med 1, Dept Med 2, Dept Cardiovasc Med, Prague 10000, Czech Republic
[4] Gen Univ Hosp, Prague 10000, Czech Republic
[5] Gen Hosp Celje, Emergency Ctr, Oblakova 5, Celje 3000, Slovenia
[6] Univ Med Ctr, Dept Cardiovasc Surg, Zaloska 7, Ljubljana 1000, Slovenia
[7] Univ Ljubljana, Fac Med, Vrazov Trg 2, Ljubljana 1000, Slovenia
来源
MEDICINA-LITHUANIA | 2024年 / 60卷 / 11期
关键词
extracorporeal membrane oxygenation; air embolism; complications; simulation;
D O I
10.3390/medicina60111883
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: This study aimed to investigate the risk and mechanisms of air entry into the extracorporeal membrane oxygenation (ECMO) circuit through the central venous catheter (CVC) in a veno-venous configuration. The primary goal was to assess the impact of different air volumes on ECMO circuit performance at varying pump speeds. Material and Methods: The study utilized a circuit model to simulate ECMO conditions and evaluate the potential entry points of air, specifically through the unprotected lumen of the CVC. Various interventions, such as the use of a closed three-way stopcock or clave, were implemented to assess their efficacy in preventing air entry. Results: The unprotected lumen of the central venous catheter posed a significant risk for air entry into the ECMO circuit. The introduction of a closed three-way stopcock or clave proved effective in preventing air ingress through the central venous catheter. Auditory cues, such as a distinct hissing sound, served as an early warning sign of air presence in the circuit. The study demonstrated that even small volumes of air, as minimal as 1 mL, could pass through the oxygenator at specific pump speeds, and larger volumes could lead to pump dysfunction. Conclusions: The study identified the unprotected lumen of the central venous catheter as a potential entry point for air into the ECMO circuit. The use of a closed three-way stopcock or one-way valve was found to be a reliable protective measure against air infiltration. Early detection through the observation of a hissing sound in the circuit provided a valuable warning sign. These findings contribute to enhancing the safety and performance of ECMO systems by minimizing the risk of air embolism.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Anatomic changes after repair of traumatic bilateral diaphragmatic rupture impede bi-caval dual lumen catheter insertion for veno-venous extracorporeal membrane oxygenation treatment
    Alexa Hollinger
    Daniel Tuchscherer
    Jens Bremerich
    Martin Siegemund
    Critical Care, 21
  • [32] Veno-venous extracorporeal membrane oxygenation using an innovative dual-lumen cannula following implantation of a total artificial heart
    Youdle, Jemma
    Penn, Sarah
    Maunz, Olaf
    Simon, Andre
    PERFUSION-UK, 2017, 32 (01): : 81 - 83
  • [33] Knowledge and Practices Regarding Prevention of Central Venous Catheter Removal-Associated Air Embolism: A Survey of Nonintensive Care Unit Medical and Nursing Staff
    Karlinskaya, Maria
    Scharf, Liad
    Sarid, Nadav
    JOURNAL OF PATIENT SAFETY, 2024, 20 (08) : 571 - 575
  • [34] Central blindness following general anaesthesia due to suspected catheter-related venous air embolism in a gelding
    Makra, Zita
    Bodo, Gabor
    Veres-Nyeki, Kata Orsolya
    VETERINARY RECORD CASE REPORTS, 2019, 7 (03):
  • [35] Use of Extracorporeal Membrane Oxygenation- Facilitated Large-Bore Catheter Embolectomy in the Treatment of Acute Pulmonary Embolism Complicated by Shock
    Glazier, Hugh A.
    Kaki, Amir
    TEXAS HEART INSTITUTE JOURNAL, 2024, 51 (02)
  • [36] A simulation study of left ventricular decompression using a double lumen arterial cannula prototype during a veno-arterial extracorporeal membrane oxygenation
    Jezek, Filip
    Strunina, Svitlana
    Carlson, Brian E.
    Hozman, Jiri
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2019, 42 (12) : 748 - 756
  • [37] Feasibility and outcomes with subclavian vein access for crescent jugular dual lumen catheter for venovenous extracorporeal membrane oxygenation in COVID-19 related acute respiratory distress syndrome
    Memon, Sehrish
    Drosou, Maria Eleni
    Caroline, Mara
    Casanova, Elena
    Gnall, Eric M.
    PERFUSION-UK, 2024, 39 (02): : 304 - 309
  • [38] Optimal Settings at Initiation of Veno-Venous Extracorporeal Membrane Oxygenation: An Exploratory In-Silico Study
    Joyce, Christopher J.
    Shekar, Kiran
    Walsham, James
    ASAIO JOURNAL, 2023, 69 (01) : E28 - E34
  • [39] Double lumen bi-cava cannula for veno-venous extracorporeal membrane oxygenation as bridge to lung transplantation in non-intubated patient
    Reeb, Jeremie
    Falcoz, Pierre-Emmanuel
    Santelmo, Nicola
    Massard, Gilbert
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2012, 14 (01) : 125 - 127
  • [40] Venous Cannula Positioning in Arterial Deoxygenation During Veno-Arterial Extracorporeal Membrane Oxygenation-A Simulation Study and Case Report
    Lindfors, Mattias
    Frenckner, Bjoern
    Sartipy, Ulrik
    Bjaellmark, Anna
    Broome, Michael
    ARTIFICIAL ORGANS, 2017, 41 (01) : 75 - 81