Prevention of Air Embolism in Extracorporeal Membrane Oxygenation Systems: An In Vitro Study on Protection of Central Venous Catheter Lumen

被引:0
作者
Franco, Danilo [1 ,2 ,3 ,4 ]
Krasna, Nejc [5 ]
Novak, Robert [6 ]
Esposito, Giovanni [2 ]
Izzo, Raffaele [2 ]
Belohlavek, Jan [3 ,4 ]
Noc, Marko [1 ,7 ]
Goslar, Tomaz [1 ,7 ]
机构
[1] Univ Med Ctr, Ctr Intens Internal Med, Zaloska 7, Ljubljana 1000, Slovenia
[2] Univ Naples Federico II, Dept Adv Biomed Sci, Via Pansini 5, I-80131 Naples, Italy
[3] Charles Univ Prague, Fac Med 1, Dept Med 2, Dept Cardiovasc Med, Prague 10000, Czech Republic
[4] Gen Univ Hosp, Prague 10000, Czech Republic
[5] Gen Hosp Celje, Emergency Ctr, Oblakova 5, Celje 3000, Slovenia
[6] Univ Med Ctr, Dept Cardiovasc Surg, Zaloska 7, Ljubljana 1000, Slovenia
[7] Univ Ljubljana, Fac Med, Vrazov Trg 2, Ljubljana 1000, Slovenia
来源
MEDICINA-LITHUANIA | 2024年 / 60卷 / 11期
关键词
extracorporeal membrane oxygenation; air embolism; complications; simulation;
D O I
10.3390/medicina60111883
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: This study aimed to investigate the risk and mechanisms of air entry into the extracorporeal membrane oxygenation (ECMO) circuit through the central venous catheter (CVC) in a veno-venous configuration. The primary goal was to assess the impact of different air volumes on ECMO circuit performance at varying pump speeds. Material and Methods: The study utilized a circuit model to simulate ECMO conditions and evaluate the potential entry points of air, specifically through the unprotected lumen of the CVC. Various interventions, such as the use of a closed three-way stopcock or clave, were implemented to assess their efficacy in preventing air entry. Results: The unprotected lumen of the central venous catheter posed a significant risk for air entry into the ECMO circuit. The introduction of a closed three-way stopcock or clave proved effective in preventing air ingress through the central venous catheter. Auditory cues, such as a distinct hissing sound, served as an early warning sign of air presence in the circuit. The study demonstrated that even small volumes of air, as minimal as 1 mL, could pass through the oxygenator at specific pump speeds, and larger volumes could lead to pump dysfunction. Conclusions: The study identified the unprotected lumen of the central venous catheter as a potential entry point for air into the ECMO circuit. The use of a closed three-way stopcock or one-way valve was found to be a reliable protective measure against air infiltration. Early detection through the observation of a hissing sound in the circuit provided a valuable warning sign. These findings contribute to enhancing the safety and performance of ECMO systems by minimizing the risk of air embolism.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Accidental placement of venous return catheter in the superior vena cava during venovenous extracorporeal membrane oxygenation for severe pneumonia: A case report
    Song, Xiao-Qin
    Jiang, Yun-Long
    Zou, Xian-Bao
    Chen, Shi-Chao
    Qu, Ai-Jun
    Guo, Ling-Ling
    WORLD JOURNAL OF CLINICAL CASES, 2024, 12 (04)
  • [22] Venoarterial extracorporeal membrane oxygenation for "protected" catheter-based embolectomy in high-risk/massive pulmonary embolism
    Brewer, Joseph M.
    Sparling, Jeffrey
    Maybauer, Marc O.
    PERFUSION-UK, 2024, 39 (05): : 1009 - 1013
  • [23] Successful treatment of peripartum massive pulmonary embolism with extracorporeal membrane oxygenation and catheter-directed pulmonary thrombolytic therapy
    Weinberg, L.
    Kay, C.
    Liskaser, E.
    Jones, D.
    Tay, S.
    Jaffe, S.
    Seevanayagam, S.
    Doolan, L.
    ANAESTHESIA AND INTENSIVE CARE, 2011, 39 (03) : 486 - 491
  • [24] Dexmedetomidine extraction by the extracorporeal membrane oxygenation circuit: results from an in vitro study
    Dallefeld, Samantha H.
    Sherwin, Jennifer
    Zimmerman, Kanecia O.
    Watt, Kevin M.
    PERFUSION-UK, 2020, 35 (03): : 209 - 216
  • [25] Fatal air embolism as complication of percutaneous dilatational tracheostomy on venovenous extracorporeal membrane oxygenation, two case reports
    Lother, Achim
    Wengenmayer, Tobias
    Benk, Christoph
    Bode, Christoph
    Staudacher, Dawid L.
    JOURNAL OF CARDIOTHORACIC SURGERY, 2016, 11
  • [26] Fatal air embolism as complication of percutaneous dilatational tracheostomy on venovenous extracorporeal membrane oxygenation, two case reports
    Achim Lother
    Tobias Wengenmayer
    Christoph Benk
    Christoph Bode
    Dawid L. Staudacher
    Journal of Cardiothoracic Surgery, 11
  • [27] Reconfiguration from veno-arterial to veno-arterio-venous extracorporeal membrane oxygenation for massive pulmonary embolism
    Takeo Matsuyoshi
    Keiki Shimizu
    Hitoshi Kaneko
    Daiyu Kohsen
    Hiroaki Suzuki
    Journal of Artificial Organs, 2022, 25 : 368 - 372
  • [28] Reconfiguration from veno-arterial to veno-arterio-venous extracorporeal membrane oxygenation for massive pulmonary embolism
    Matsuyoshi, Takeo
    Shimizu, Keiki
    Kaneko, Hitoshi
    Kohsen, Daiyu
    Suzuki, Hiroaki
    JOURNAL OF ARTIFICIAL ORGANS, 2022, 25 (04) : 368 - 372
  • [29] Massive air embolism from central venous catheter during veno-arterial ECMO therapy
    Omar, Edris
    Lebreton, Guillaume
    Bougle, Adrien
    Amour, Julien
    ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2018, 37 (03) : 271 - 272
  • [30] Echocardiographic diagnosis of air embolism associated with central venous catheter placement: Case report and review of the literature
    Maddukuri, P
    Downey, BC
    Blander, JA
    Pandian, NG
    Patel, AR
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2006, 23 (04): : 315 - 318