Comparison of oropharyngeal leak pressure of I-gel™ and Blockbuster™ laryngeal mask airway in anaesthetized pediatric patients

被引:3
|
作者
Selvin, Caren Candace [1 ]
Singariya, Geeta [1 ]
Bihani, Pooja [1 ]
Kamal, Manoj [2 ]
Paliwal, Naveen [1 ]
Ujwal, Shobha [1 ]
机构
[1] Dr SN Med Coll Jodhpur, Dept Anesthesiol & Crit Care, Jodhpur, India
[2] All India Inst Med Sci Jodhpur, Dept Anesthesiol & Crit Care, 123 Vaishali Ave,Jhanwar Rd, Jodhpur 342008, Rajasthan, India
来源
ANESTHESIA AND PAIN MEDICINE | 2023年 / 18卷 / 01期
关键词
Blockbuster LMA; I-gel; Pediatric anesthesia; Supraglottic airways; I-GEL; GENERAL-ANESTHESIA; CHILDREN; PERFORMANCE; DEVICES;
D O I
10.17085/apm.22209
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Supraglottic airways (SGA) are increasingly used in pediatric anesthesia. Among SGA, I-gel (TM) is a commonly used device in pediatric patients. The Blockbuster (TM) laryngeal mask airway (LMA) is latest addition in pediatric airway armamentarium. This study was conducted to compare the clinical performance of I-gel (TM) and Blockbuster (TM) LMA in pediatric patients. Methods: A total of 140 children aged 1-5 years, who were undergoing elective surgery, were randomized into two groups either I-gel (TM) (Group I) or Blockbuster (TM) LMA (Group B). Air-way was secured with appropriate-sized LMA according to group allocation under general anesthesia. The primary objective of study was oropharyngeal leak pressures (OPLP), and secondary objectives were number of attempts of device insertion, success rate, ease of LMA insertion, hemodynamic parameters, and postoperative pharyngolaryngeal morbidities. Results: The mean OPLP was significantly higher for I-gel (TM) compared to Blockbuster (TM) LMA (27.97 +/- 1.65 vs. 26.04 +/- 2.12; P < 0.001). The devices were successfully inserted on the first attempt in 97.14% and 90% of the Group I and Group B respectively. The insertion time, ease of insertion, hemodynamic parameters and postoperative complications were compa-rable between groups. Conclusions: The I-gel (TM) was more efficacious device in term of OPLP than Blockbuster (TM) LMA for positive pressure ventilation in pediatric patients undergoing short surgical proce-dures under general anesthesia.
引用
收藏
页码:51 / 56
页数:121
相关论文
共 50 条
  • [41] A randomized comparison of the laryngeal mask airway supreme and laryngeal mask airway unique in infants and children: does cuff pressure influence leak pressure?
    Jagannathan, Narasimhan
    Sohn, Lisa
    Sommers, Katherine
    Belvis, Dawn
    Shah, Ravi D.
    Sawardekar, Amod
    Eidem, Jami
    DaGraca, Justin
    Mukherji, Isabella
    PEDIATRIC ANESTHESIA, 2013, 23 (10) : 927 - 933
  • [42] The comparison of ProSeal and I-gel laryngeal mask airways in anesthetized adult patients under controlled ventilation
    Ekinci, Osman
    Abitagaoglu, Suheyla
    Turan, Guldem
    Sivrikaya, Zubeyir
    Bosna, Gulsen
    Ozgultekin, Asu
    SAUDI MEDICAL JOURNAL, 2015, 36 (04) : 432 - 436
  • [43] A systematic review and meta-analysis of the i-gel® vs laryngeal mask airway in adults
    de Montblanc, J.
    Ruscio, L.
    Mazoit, J. X.
    Benhamou, D.
    ANAESTHESIA, 2014, 69 (10) : 1151 - 1162
  • [44] A comparison of fibreoptic-guided tracheal intubation through the Ambu®Aura-i™, the intubating laryngeal mask airway and the i-gel™: a manikin study
    de Lloyd, L. J.
    Subash, F.
    Wilkes, A. R.
    Hodzovic, I.
    ANAESTHESIA, 2015, 70 (05) : 591 - 597
  • [45] Comparison of the oropharyngeal leak pressure between three second generation supraglottic airway devices during laparoscopic surgery in pediatric patients
    Kumar, Abhyuday
    Sinha, Chandni
    Kumar, Neeraj
    Kumar, Ajeet
    Kumar, Bindey
    Kumar, Amarjeet
    Kumar, Rajnish
    PEDIATRIC ANESTHESIA, 2022, 32 (07) : 843 - 850
  • [46] Fiberoptic intubation of severely obese patients through supraglottic airway: A prospective, randomized trial of the Ambu® AuraGain™ laryngeal mask vs the i-gel™ airway
    Moser, Berthold
    Keller, Christian
    Audige, Laurent
    Dave, Mital H.
    Bruppacher, Heinz R.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2019, 63 (02) : 187 - 194
  • [47] A randomized comparison of volume- and pressure-controlled ventilation in children with the i-gel Effects on peak inspiratory pressure, oropharyngeal leak pressure, and gastric insufflation
    Park, Jin Ha
    Kim, Ji Young
    Park, Kyoungun
    Kil, Hae Keum
    MEDICINE, 2017, 96 (18)
  • [48] Comparison of i-gel®, Ambu® AuraGain™, Baska Mask, LMA® Protector™ for airway management of obese surgical patients - A randomised comparative study
    Raman, Rajesh
    Gupta, Apoorva
    Prabha, Rati
    Gautam, Shefali
    Anand, Akshay
    INDIAN JOURNAL OF ANAESTHESIA, 2025, 69 (03) : 289 - 295
  • [49] Comparison of the effects of paratracheal pressure and cricoid pressure on placement of the i-gel® supraglottic airway: a randomized clinical trial
    Won, Dongwook
    Kim, Hyerim
    Chang, Jee-Eun
    Lee, Jung-Man
    Kim, Tae Kyong
    Kim, Honghyeon
    Min, Seong-Won
    Hwang, Jin-Young
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2024, 71 (07): : 996 - 1003
  • [50] Instrumental and randomised clinical comparison between laryngeal mask airway Proseal and Supreme in pediatric patients
    Santambrogio, Luisa
    Righi, Sabrina
    Pinciroli, Rosa L.
    Piro, Eugenia
    D'alessio, Antonio
    Minuto, Aldo
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2020, 30 : 14 - 21