Functional Mobility Studies in Younger Adults: Instrumented Timed Up and Go (iTUG) Test Using Inertial Devices

被引:0
|
作者
Kowal, Mateusz [1 ]
Winiarski, Slawomir [2 ]
Morgiel, Ewa [3 ]
Madej, Marta [3 ]
Proc, Krzysztof [4 ]
Madziarski, Marcin [4 ]
Wedel, Nicole [5 ]
Sebastian, Agata [3 ]
机构
[1] Wroclaw Med Univ, Univ Ctr Physiotherapy & Rehabil, Fac Physiotherapy, Physiotherapy Res Lab, PL-50368 Wroclaw, Poland
[2] Wroclaw Univ Hlth & Sport Sci, Dept Physiol & Biomech, Paderewskiego 35, PL-51612 Wroclaw, Poland
[3] Wroclaw Med Univ, Dept & Clin Rheumatol & Internal Med, Borowska St 213, PL-50556 Wroclaw, Poland
[4] Univ Hosp, Dept & Clin Rheumatol & Internal Med, Borowska St 213, PL-50556 Wroclaw, Poland
[5] Albert Einstein Coll Med, Dept Med, 1300 Morris Pk Ave, New York, NY 10461 USA
关键词
motion analysis; functional mobility assessment; normative data; OLDER-PEOPLE; BALANCE; WOMEN;
D O I
10.3390/jcm14061944
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Functional Mobility Assessment (FMA) is a challenging task. One example of an FMA is an instrumented Timed Up and Go test (iTUG). Sensor-based interventions are more effective than traditional interventions that use clinical tests to assess a patient's FMA. Background/Objectives: The aim of this study is to investigate the variability of selected parameters of the instrumented Time Up and Go test using inertial measurements in healthy younger adults. Methods: A total of 73 subjects participated in the study, including 37 women and 36 men. The mean age was 31 years (SD 5.5 years), the mean height [cm] was 176.2 (SD 91), and the mean BMI [kg/m2] was 26.6 (SD 3.1). The Noraxon MyoMotion Research 18 motion analysis system was used to record raw spatial data. Results: The mean total time to complete the iTUG test was 13.1 +/- 1.9 s with a low coefficient of variation (CV), suggesting consistent performance between participants. The recorded spatial and temporal parameters of the gait variables, as well as the kinematic variables of the iTUG test of the studied group of healthy adults, show low variability, except for the mean double support ratio (R - L)/(R + L), which was 4.1 +/- 11.0% with a CV of 271.5%, indicating a very high variability. Conclusions: The low variability observed in key parameters, such as total time and percentage of posture, suggests that the iTUG test provides reliable, objective, and reproducible measurements that can serve as normative benchmarks for healthy adults.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Associations Between Physical Performance and Executive Function in Older Adults With Mild Cognitive Impairment: Gait Speed and the Timed "Up & Go" Test
    McGough, Ellen L.
    Kelly, Valerie E.
    Logsdon, Rebecca G.
    McCurry, Susan M.
    Cochrane, Barbara B.
    Engel, Joyce M.
    Teri, Linda
    PHYSICAL THERAPY, 2011, 91 (08): : 1198 - 1207
  • [42] Is the Timed Up and Go test a useful predictor of risk of falls in community dwelling older adults: a systematic review and meta- analysis
    Barry, Emma
    Galvin, Rose
    Keogh, Claire
    Horgan, Frances
    Fahey, Tom
    BMC GERIATRICS, 2014, 14
  • [43] RESPONSIVENESS TO SENSORY CUES USING THE TIMED UP AND GO TEST IN PATIENTS WITH PARKINSON'S DISEASE: A PROSPECTIVE COHORT STUDY
    Cioni, Matteo
    Amata, Oriana
    Seminara, Maria Rosaria
    Marano, Pietro
    Palermo, Filippo
    Corallo, Viviana
    Brugliera, Luigia
    JOURNAL OF REHABILITATION MEDICINE, 2015, 47 (09) : 824 - 829
  • [44] Reference values for the Timed Up and Go test in healthy Japanese elderly people: Determination using the methodology of meta-analysis
    Kamide, Naoto
    Takahashi, Kayoko
    Shiba, Yoshitaka
    GERIATRICS & GERONTOLOGY INTERNATIONAL, 2011, 11 (04) : 445 - 451
  • [45] Using a Body-Fixed Sensor to Identify Subclinical Gait Difficulties in Older Adults with IADL Disability: Maximizing the Output of the Timed Up and Go
    Weiss, Aner
    Mirelman, Anat
    Buchman, Aron S.
    Bennett, David A.
    Hausdorff, Jeffrey M.
    PLOS ONE, 2013, 8 (07):
  • [46] Evaluation of the instrumented Timed Up and Go test as a tool to measure exercise intervention effects in nursing home residents: results from a PROCARE substudy; [Bewertung des instrumentierten Timed-Up-and-Go-Tests als Instrument zur Messung der Auswirkungen von Bewegungsinterventionen bei Pflegeheimbewohnern: Ergebnisse einer PROCARE-Teilstudie]
    Klotzbier T.J.
    Korbus H.
    Johnen B.
    Schott N.
    German Journal of Exercise and Sport Research, 2021, 51 (4) : 430 - 442
  • [47] Factors Contributing to Single- and Dual-Task Timed "Up & Go" Test Performance in Middle-Aged and Older Adults Who Are Active and Dwell in the Community
    Chen, Hui-Ya
    Tang, Pei-Fang
    PHYSICAL THERAPY, 2016, 96 (03): : 284 - 292
  • [48] Alzheimer's Disease Detection Using Comprehensive Analysis of Timed Up and Go Test via Kinect V.2 Camera and Machine Learning
    Seifallahi, Mahmoud
    Mehraban, Afsoon Hasani
    Galvin, James E.
    Ghoraani, Behnaz
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2022, 30 : 1589 - 1600
  • [49] The reliability of the quantitative timed up and go test (QTUG) measured over five consecutive days under single and dual-task conditions in community dwelling older adults
    Smith, Erin
    Walsh, Lorcan
    Doyle, Julie
    Greene, Barry
    Blake, Catherine
    GAIT & POSTURE, 2016, 43 : 239 - 244
  • [50] Association of timed up and go test outcomes with future incidence of cardiovascular disease and mortality in adults aged 66 years: Korean national representative longitudinal study over 5.7 years
    Son, Ki Young
    Shin, Dong Wook
    Lee, Ji Eun
    Kim, Sang Hyuck
    Yun, Jae Moon
    Cho, Belong
    BMC GERIATRICS, 2020, 20 (01)