Functional Mobility Studies in Younger Adults: Instrumented Timed Up and Go (iTUG) Test Using Inertial Devices

被引:0
|
作者
Kowal, Mateusz [1 ]
Winiarski, Slawomir [2 ]
Morgiel, Ewa [3 ]
Madej, Marta [3 ]
Proc, Krzysztof [4 ]
Madziarski, Marcin [4 ]
Wedel, Nicole [5 ]
Sebastian, Agata [3 ]
机构
[1] Wroclaw Med Univ, Univ Ctr Physiotherapy & Rehabil, Fac Physiotherapy, Physiotherapy Res Lab, PL-50368 Wroclaw, Poland
[2] Wroclaw Univ Hlth & Sport Sci, Dept Physiol & Biomech, Paderewskiego 35, PL-51612 Wroclaw, Poland
[3] Wroclaw Med Univ, Dept & Clin Rheumatol & Internal Med, Borowska St 213, PL-50556 Wroclaw, Poland
[4] Univ Hosp, Dept & Clin Rheumatol & Internal Med, Borowska St 213, PL-50556 Wroclaw, Poland
[5] Albert Einstein Coll Med, Dept Med, 1300 Morris Pk Ave, New York, NY 10461 USA
关键词
motion analysis; functional mobility assessment; normative data; OLDER-PEOPLE; BALANCE; WOMEN;
D O I
10.3390/jcm14061944
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Functional Mobility Assessment (FMA) is a challenging task. One example of an FMA is an instrumented Timed Up and Go test (iTUG). Sensor-based interventions are more effective than traditional interventions that use clinical tests to assess a patient's FMA. Background/Objectives: The aim of this study is to investigate the variability of selected parameters of the instrumented Time Up and Go test using inertial measurements in healthy younger adults. Methods: A total of 73 subjects participated in the study, including 37 women and 36 men. The mean age was 31 years (SD 5.5 years), the mean height [cm] was 176.2 (SD 91), and the mean BMI [kg/m2] was 26.6 (SD 3.1). The Noraxon MyoMotion Research 18 motion analysis system was used to record raw spatial data. Results: The mean total time to complete the iTUG test was 13.1 +/- 1.9 s with a low coefficient of variation (CV), suggesting consistent performance between participants. The recorded spatial and temporal parameters of the gait variables, as well as the kinematic variables of the iTUG test of the studied group of healthy adults, show low variability, except for the mean double support ratio (R - L)/(R + L), which was 4.1 +/- 11.0% with a CV of 271.5%, indicating a very high variability. Conclusions: The low variability observed in key parameters, such as total time and percentage of posture, suggests that the iTUG test provides reliable, objective, and reproducible measurements that can serve as normative benchmarks for healthy adults.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Quantification of Motor Impairment in Parkinson's Disease Using an Instrumented Timed Up and Go Test
    Palmerini, Luca
    Mellone, Sabato
    Avanzolini, Guido
    Valzania, Franco
    Chiari, Lorenzo
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2013, 21 (04) : 664 - 673
  • [22] Towards Using the Instrumented Timed Up-and-Go Test for Screening of Sensory System Performance for Balance Control in Older Adults
    Gerhardy, Thomas
    Gordt, Katharina
    Jansen, Carl-Philipp
    Schwenk, Michael
    SENSORS, 2019, 19 (03):
  • [23] Short report:: Functional mobility assessment at home -: Timed Up and Go test using three different chairs
    Eekhof, JAH
    De Bock, GH
    Schaapveld, K
    Springer, MP
    CANADIAN FAMILY PHYSICIAN, 2001, 47 : 1205 - 1207
  • [24] Imagined Timed Up and Go test (iTUG) in people with Parkinson's Disease: test-retest reliability and validity
    Moreno-Verdu, Marcos
    del Rosario Ferreira-Sanchez, Maria
    Martin-Casas, Patricia
    Atin-Arratibel, Maria Angeles
    DISABILITY AND REHABILITATION, 2024, 46 (05) : 1005 - 1015
  • [25] Estimation of Average and Maximum Daily-Life Mobility Performance Using the Timed Up-and-Go: Exploring the Added Value of an Instrumented Timed Up-and-Go
    Heldmann, Patrick
    Elser, Alexander
    Kramer-Gmeiner, Franziska
    Jansen, Carl-Philipp
    Mellone, Sabato
    Schwenk, Michael
    GERONTOLOGY, 2024, 70 (03) : 327 - 335
  • [26] Quantitative Evaluation of Gait Disturbance on an Instrumented Timed Up-and-go Test
    Yamada, Shigeki
    Aoyagi, Yukihiko
    Yamamoto, Kazuo
    Ishikawa, Masatsune
    AGING AND DISEASE, 2019, 10 (01): : 23 - 36
  • [27] The Instrumented Timed "Up & Go" Test Distinguishes Turning Characteristics in Vestibular Hypofunction
    Kim, Kyoung Jae
    Gimmon, Yoav
    Millar, Jennifer
    Brewer, Kelly
    Serrador, Jorge
    Schubert, Michael C.
    PHYSICAL THERAPY, 2021, 101 (07):
  • [28] Detecting subtle mobility changes among older adults: the Quantitative Timed Up and Go test
    Erin Smith
    Caitriona Cunningham
    Barry R. Greene
    Ulrik McCarthy Persson
    Catherine Blake
    Aging Clinical and Experimental Research, 2021, 33 : 2157 - 2164
  • [29] Detecting subtle mobility changes among older adults: the Quantitative Timed Up and Go test
    Smith, Erin
    Cunningham, Caitriona
    Greene, Barry R.
    McCarthy Persson, Ulrik
    Blake, Catherine
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2021, 33 (08) : 2157 - 2164
  • [30] Sensor based assessment of turning during instrumented Timed Up and Go Test for quantifying mobility in chronic stroke patients
    Spina, Stefania
    Facciorusso, Salvatore
    D'ascanio, Milena C.
    Morone, Giovanni
    Baricich, Alessio
    Fiore, Pietro
    Santamato, Andrea
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2023, 59 (01) : 6 - 13