Functional Mobility Studies in Younger Adults: Instrumented Timed Up and Go (iTUG) Test Using Inertial Devices

被引:0
|
作者
Kowal, Mateusz [1 ]
Winiarski, Slawomir [2 ]
Morgiel, Ewa [3 ]
Madej, Marta [3 ]
Proc, Krzysztof [4 ]
Madziarski, Marcin [4 ]
Wedel, Nicole [5 ]
Sebastian, Agata [3 ]
机构
[1] Wroclaw Med Univ, Univ Ctr Physiotherapy & Rehabil, Fac Physiotherapy, Physiotherapy Res Lab, PL-50368 Wroclaw, Poland
[2] Wroclaw Univ Hlth & Sport Sci, Dept Physiol & Biomech, Paderewskiego 35, PL-51612 Wroclaw, Poland
[3] Wroclaw Med Univ, Dept & Clin Rheumatol & Internal Med, Borowska St 213, PL-50556 Wroclaw, Poland
[4] Univ Hosp, Dept & Clin Rheumatol & Internal Med, Borowska St 213, PL-50556 Wroclaw, Poland
[5] Albert Einstein Coll Med, Dept Med, 1300 Morris Pk Ave, New York, NY 10461 USA
关键词
motion analysis; functional mobility assessment; normative data; OLDER-PEOPLE; BALANCE; WOMEN;
D O I
10.3390/jcm14061944
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Functional Mobility Assessment (FMA) is a challenging task. One example of an FMA is an instrumented Timed Up and Go test (iTUG). Sensor-based interventions are more effective than traditional interventions that use clinical tests to assess a patient's FMA. Background/Objectives: The aim of this study is to investigate the variability of selected parameters of the instrumented Time Up and Go test using inertial measurements in healthy younger adults. Methods: A total of 73 subjects participated in the study, including 37 women and 36 men. The mean age was 31 years (SD 5.5 years), the mean height [cm] was 176.2 (SD 91), and the mean BMI [kg/m2] was 26.6 (SD 3.1). The Noraxon MyoMotion Research 18 motion analysis system was used to record raw spatial data. Results: The mean total time to complete the iTUG test was 13.1 +/- 1.9 s with a low coefficient of variation (CV), suggesting consistent performance between participants. The recorded spatial and temporal parameters of the gait variables, as well as the kinematic variables of the iTUG test of the studied group of healthy adults, show low variability, except for the mean double support ratio (R - L)/(R + L), which was 4.1 +/- 11.0% with a CV of 271.5%, indicating a very high variability. Conclusions: The low variability observed in key parameters, such as total time and percentage of posture, suggests that the iTUG test provides reliable, objective, and reproducible measurements that can serve as normative benchmarks for healthy adults.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Instrumented Timed Up and Go Test Using Inertial Sensors from Consumer Wearable Devices
    Matey-Sanz, Miguel
    Gonzalez-Perez, Alberto
    Casteleyn, Sven
    Granell, Carlos
    ARTIFICIAL INTELLIGENCE IN MEDICINE, AIME 2022, 2022, 13263 : 144 - 154
  • [2] UMATUG: A dataset of inertial signals of older and young adults using a gerontologic simulator collected during instrumented Timed Up and Go (iTUG) tests
    Silva, Carlos A.
    Casilari, Eduardo
    Garcia-Bermudez, Rodolfo
    DATA IN BRIEF, 2024, 55
  • [3] Use of an Instrumented Timed Up and Go (iTUG) for Fall Risk Classification
    Jackson, Kurt
    Sample, Renee
    Bigelow, Kimberly
    PHYSICAL & OCCUPATIONAL THERAPY IN GERIATRICS, 2018, 36 (04) : 354 - 365
  • [4] Gait and mobility deficits in FXTAS using the instrumented timed up and go test
    O'Keefe, J. A.
    Kohjima, J. W.
    Walsh, M. E.
    Berry-Kravis, E.
    Hall, D. A.
    MOVEMENT DISORDERS, 2014, 29 : S478 - S478
  • [5] Longitudinal monitoring of gait and mobility in Parkinson's disease (PD) using an instrumented timed tip and go test (iTUG)
    Horak, F.
    Zampieri, C.
    Salarian, A.
    Carlson-Kuhta, P.
    Aminian, K.
    Nutt, J.
    MOVEMENT DISORDERS, 2009, 24 : S403 - S403
  • [6] Instrumented Timed Up and Go Test (iTUG)-More Than Assessing Time to Predict Falls: A Systematic Review
    Ortega-Bastidas, Paulina
    Gomez, Britam
    Aqueveque, Pablo
    Luarte-Martinez, Soledad
    Cano-de-la-Cuerda, Roberto
    SENSORS, 2023, 23 (07)
  • [7] Predicting Advanced Balance Ability and Mobility with an Instrumented Timed Up and Go Test
    Bergquist, Ronny
    Nerz, Corinna
    Taraldsen, Kristin
    Mellone, Sabato
    Ihlen, Espen A. F.
    Vereijken, Beatrix
    Helbostad, Jorunn L.
    Becker, Clemens
    Mikolaizak, A. Stefanie
    SENSORS, 2020, 20 (17) : 1 - 14
  • [8] Effects of using assistive devices on the components of the modified instrumented timed up and go test in healthy subjects
    Abualait, Turki S.
    Alnajdi, Ghazi K.
    HELIYON, 2021, 7 (04)
  • [9] Assessment of functional mobility and gait during a timed up and go test in adults with total blindness
    Parreira, Rodolfo Borges
    Lopes, Jamile Benite Palma
    Cordeiro, Lorraine Barbosa
    Galli, Manuela
    Oliveira, Claudia Santos
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2023, 35 : 298 - 304
  • [10] Assessing mobility at home in people with early Parkinson's disease using an instrumented Timed Up and Go test
    Zampieri, Cris
    Salarian, Arash
    Carlson-Kuhta, Patricia
    Nutt, John G.
    Horak, Fay B.
    PARKINSONISM & RELATED DISORDERS, 2011, 17 (04) : 277 - 280