Effects of an active ankle exoskeleton on the walking biomechanics of healthy men

被引:0
作者
Nagaraja, Sridevi [1 ,2 ]
Rubio, Jose E. [1 ,2 ]
Tong, Junfei [1 ,2 ]
Sundaramurthy, Aravind [1 ,2 ]
Pant, Anup [1 ,2 ]
Owen, Meredith K. [3 ]
Samaan, Michael A. [4 ]
Noehren, Brian [3 ]
Reifman, Jaques [1 ]
机构
[1] Med Res & Dev Command, Dept Def Biotechnol, High Performance Comp Software Applicat Inst, Telemed & Adv Technol Res Ctr,Def Hlth Agcy Res &, Ft Detrick, MD 21702 USA
[2] Henry M Jackson Fdn Advancement Mil Med Inc, Bethesda, MD USA
[3] Univ Kentucky, Dept Phys Therapy, Lexington, KY USA
[4] Univ Kentucky, Dept Kinesiol & Hlth Promot, Lexington, KY USA
来源
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY | 2025年 / 13卷
关键词
exoskeleton; individualized models; walking; load carriage; musculoskeletal biomechanics; LOAD CARRIAGE INJURIES; METABOLIC COST; INCLINE WALKING; MUSCLE; FATIGUE; HIP; ASSISTANCE; MECHANICS; PAIN; GAIT;
D O I
10.3389/fbioe.2025.1533001
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Active lower-body exoskeleton devices can decrease the energy requirement of the human body by providing mechanical assistance to lower-body muscles. However, they also alter gait kinematics and kinetics, and it is not well understood whether such alterations are detrimental or beneficial to the human body. In this pilot study, we investigated the impact of walking with an ankle exoskeleton device on the biomechanics of men while carrying a heavy load. We collected computed tomography images and motion-capture data for five young, healthy men who walked 5 km (similar to 60 min) with a 22.7-kg load, with and without an active ankle exoskeleton (the ExoBoot EB60). We developed personalized musculoskeletal models and calculated the joint kinematics and kinetics for each participant under each walking condition. Without the ExoBoot, at 5 km compared to 0 km, on average, the peak trunk flexion angle increased by similar to 35% and the stride length increased by similar to 3.5%. In contrast, with the ExoBoot, the magnitude of the corresponding increases was smaller (similar to 16% and similar to 2%, respectively). After the 5-km walk, compared to walking without the ExoBoot, its use considerably altered hip-related biomechanical parameters, e.g., it increased hip abduction angle by similar to 17%, increased hip flexion moment by similar to 3.5%, and decreased hip adduction moment by similar to 19%. Finally, irrespective of distance, ExoBoot use significantly increased the stance duration and peak ankle plantarflexion angle (p < 0.001). Overall, the use of the ExoBoot induced beneficial alterations in stride length and trunk-, ankle-, and hip-related parameters for men walking with load carriage. The quantitative analysis provided by this pilot study should help guide future investigations and inform the development of standards for safe and effective use of emerging exoskeleton technologies.
引用
收藏
页数:16
相关论文
共 75 条
  • [1] Individuals differ in muscle activation patterns during early adaptation to a powered ankle exoskeleton
    Acosta-Sojo, Yadrianna
    Stirling, Leia
    [J]. APPLIED ERGONOMICS, 2022, 98
  • [2] [Anonymous], 2015, Demographics: Profile of the Military Community
  • [3] Baldon RD, 2009, J ATHL TRAINING, V44, P490, DOI 10.4085/1062-6050-44.5.490
  • [4] Effect of fatigue and gender on kinematics and ground reaction forces variables in recreational runners
    Bazuelo-Ruiz, Bruno
    Dura-Gil, Juan V.
    Palomares, Nicolas
    Medina, Enrique
    Llana-Belloch, Salvador
    [J]. PEERJ, 2018, 6
  • [5] CONTROLLING THE FALSE DISCOVERY RATE - A PRACTICAL AND POWERFUL APPROACH TO MULTIPLE TESTING
    BENJAMINI, Y
    HOCHBERG, Y
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1995, 57 (01) : 289 - 300
  • [6] Spatiotemporal and Kinematic Comparisons Between Anthropometrically Paired Male and Female Soldiers While Walking With Heavy Loads
    Bode, Victoria G.
    Frykman, Peter N.
    Smith, Nathaniel, I
    Fellin, Rebecca E.
    Seay, Joseph F.
    [J]. MILITARY MEDICINE, 2021, 186 (3-4) : 387 - 392
  • [7] Robotic exoskeletons: a review of recent progress
    Bogue, Robert
    [J]. INDUSTRIAL ROBOT-AN INTERNATIONAL JOURNAL, 2015, 42 (01) : 5 - 10
  • [8] Hip strength and hip and knee kinematics during stair descent in females with and without patellofemoral pain syndrome
    Bolgla, Lori A.
    Malone, Terry R.
    Umberger, Brian R.
    Uhl, Timothy L.
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2008, 38 (01) : 12 - 18
  • [9] ELECTRO-MECHANICAL DELAY IN HUMAN SKELETAL-MUSCLE UNDER CONCENTRIC AND ECCENTRIC CONTRACTIONS
    CAVANAGH, PR
    KOMI, PV
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1979, 42 (03) : 159 - 163
  • [10] Effects of Fatigue on Running Mechanics Associated with Tibial Stress Fracture Risk
    Clansey, Adam C.
    Hanlon, Michael
    Wallace, Eric S.
    Lake, Mark J.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 (10) : 1917 - 1923