Patient-Specific Acetabular Safe Zones in Total Hip Arthroplasty: External Validation of a Quantitative Approach to Preoperatively Templating Spinopelvic Parameters

被引:0
作者
Pang, Michael [1 ,2 ]
Vigdorchik, Jonathan M. [3 ]
Schwarzkopf, Ran [4 ]
Chen, Antonia F. [1 ,2 ]
Iorio, Richard [1 ,2 ]
Lange, Jeffrey K. [1 ,2 ]
Ramkumar, Prem N. [5 ]
机构
[1] Harvard Med Sch, Dept Orthopaed Surg, Boston, MA USA
[2] Brigham & Womens Hosp, Dept Orthopaed Surg, Boston, MA USA
[3] Hosp Special Surg, New York, NY USA
[4] NYU, Langone Hlth, New York, NY USA
[5] Commons Clin, 3828 Schaufele Ave Ste 308, Long Beach, CA 90808 USA
来源
ARTHROPLASTY TODAY | 2024年 / 30卷
关键词
Total hip arthroplasty; Revision; Spinopelvic; Instability; Safe-zones; SPINAL DEFORMITY; PELVIC TILT; COMPONENT; ORIENTATION; ANTEVERSION; MOBILITY; IMPINGEMENT; INCLINATION; INSTABILITY; POSITION;
D O I
10.1016/j.artd.2024.101508
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Spinopelvic mechanics are critical in total hip arthroplasty; however, there is no established consensus for adjusting acetabular component positioning based on spinopelvic parameters. This study aimed to (1) validate a recently developed Patient-Specific acetabular safe-zone calculator that factors in spinopelvic parameters and (2) compare differences with hip-spine classification targets. Methods: A total of 3750 patients underwent primary total hip arthroplasty across 3 academic referral centers, with 33 (0.88%) requiring revision for instability. Spinopelvic parameters were measured before initial total hip arthroplasty, and acetabular component position was measured following the index and revision procedures. Most operations employed either computer navigation or robotic assistance (94%). Surgical approaches included both anterior and posterior techniques. Utilizing our recently developed patient-specific safe-zone calculator, theoretical intraoperative positions were calculated and compared to true component positions before and after revision. Results: Among 33 patients who underwent revision, none dislocated at an average follow-up of 5.1 years. In the external validation cohort, the average absolute differences between the patient-specific safe-zone and the median hip-spine classification recommendation were 3.8 degrees +/- 2.1 degrees inclination and 5.0 degrees +/- 3.2 degrees version. For the pooled cohort, the absolute differences between the patient-specific safe-zone targets and the prerevision component positions were 7.9 degrees +/- 5.1 degrees inclination and 11.4 degrees +/- 6.9 degrees version. After revision, the mean absolute differences decreased to 3.6 degrees +/- 3.1 degrees inclination and 5.8 degrees +/- 3.5 degrees version (P < .001). Conclusions: A patient-specific approach improved acetabular component positioning accuracy within 6 degrees of version and 4 degrees of inclination of stable, revised hips. Patient-specific safe zones provide quantitative targets for nuanced spinopelvic preoperative planning that may mitigate risk of instability and may indicate use of assisted technologies. (c) 2024 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Accuracy of 3-Dimensional Planning, Implant Templating, and Patient-Specific Instrumentation in Anatomic Total Shoulder Arthroplasty
    Iannotti, Joseph P.
    Walker, Kyle
    Rodriguez, Eric
    Patterson, Thomas E.
    Jun, Bong-Jae
    Ricchetti, Eric T.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (05) : 446 - 457
  • [42] Feasibility and anteversion accuracy of a patient-specific instrument for femoral prosthesis implantation in total hip arthroplasty
    Wei Zheng
    Xuefeng Liu
    Runhong Mei
    Gaorong Deng
    Zhipeng Li
    Rongji Lin
    Shui Xiong
    Binghua Wu
    BioMedical Engineering OnLine, 22
  • [43] Effect of patient-specific instrument on lowering threshold for junior physicians to perform total hip arthroplasty on developmental dysplasia of the hip patients
    Xiao, Han
    Wang, Chenggong
    Zhong, Da
    Lei, Pengfei
    Hu, Yihe
    Su, Shilong
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (07) : 1281 - 1286
  • [44] Effect of patient-specific instrument on lowering threshold for junior physicians to perform total hip arthroplasty on developmental dysplasia of the hip patients
    Han Xiao
    Chenggong Wang
    Da Zhong
    Pengfei Lei
    Yihe Hu
    Shilong Su
    International Orthopaedics, 2020, 44 : 1281 - 1286
  • [45] Artificially Intelligent Three-Dimensionally-Printed Patient-Specific Instrument Improves Total Hip Arthroplasty Accuracy
    Chen, Xi
    Li, Songlin
    Wang, Yiou
    Liu, Xingyu
    Zhang, Yiling
    Qiu, Guixing
    Qian, Wenwei
    JOURNAL OF ARTHROPLASTY, 2023, 38 (10) : 2060 - +
  • [46] Effectiveness of a patient-specific guide for femoral stem implantation in primary total hip arthroplasty: a randomized control trial
    Xin Jin
    Mengcun Chen
    Adnan N. Cheema
    Xianzhe Liu
    Shuhua Yang
    Weihua Xu
    International Orthopaedics, 2022, 46 : 805 - 814
  • [47] A Novel Technique for Autograft Preparation Using Patient-Specific Instrumentation (PSI) Assistance in Total Hip Arthroplasty in Developmental Dysplasia of Hip (DDH)
    Lin, Chun-Ru
    Chou, Hsuan
    Luo, Chu-An
    Chang, Shu-Hao
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (09):
  • [48] Does functional planning, 3D templating and patient-specific instrumentation improve accuracy in total hip replacement?— a randomized controlled trial
    Christopher Thomas
    Vatsal Gupta
    Helen Parsons
    Andrew Metcalfe
    Pedro Foguet
    Richard King
    Arthroplasty, 4
  • [49] Femoral strain changes after total hip arthroplasty -: patient-specific finite element analyses 12 years after operation
    Lengsfeld, M
    Burchard, R
    Günther, D
    Pressel, T
    Schmitt, J
    Leppek, R
    Griss, P
    MEDICAL ENGINEERING & PHYSICS, 2005, 27 (08) : 649 - 654
  • [50] Perioperative patient-specific factors-based nomograms predict short-term periprosthetic bone loss after total hip arthroplasty
    Fu, Guangtao
    Li, Mengyuan
    Xue, Yunlian
    Li, Qingtian
    Deng, Zhantao
    Ma, Yuanchen
    Zheng, Qiujian
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)