Outcome after the early use of intra-aortic balloon pump in coronary bypass graft surgery in cases with impaired myocardial function

被引:0
|
作者
Salem, Ehab F. [1 ]
Shaalan, Ayman M. [1 ,3 ]
Alhuthaif, Abdulkareem [3 ,4 ]
Elwakeel, Eman [2 ]
Abdelazim, Ahmed M. [1 ]
机构
[1] Benha Univ, Fac Med, Dept Cardiothorac Surg, Banha, Al Qalyubia, Egypt
[2] Benha Univ, Fac Med, Dept Anat & Embryol, Banha, Al Qalyubia, Egypt
[3] Dallah Hosp, Cardiac Ctr, Cardiol Dept, Riyadh, Saudi Arabia
[4] Al Thawra Hosp, Dept Cardiol, Cardiac Ctr, Sanaa, Yemen
关键词
Coronary artery bypass grafting; intra-aortic balloon pump; left ventricular dysfunction; PLATELET COUNT; MORTALITY; RISK;
D O I
10.21608/EJSUR.2024.292632.1085
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Background: Preoperative intra-aortic balloon pump (IABP) is usually used to improve myocardial perfusion by increasing coronary blood flow during diastole with optimal timing. Its use has debatable outcomes in cases with impaired function and need of coronary artery bypass graft surgery (CABG). Objective: This study aimed to evaluate the early use of IABP preoperatively and the predictors in cases with severe to moderate impaired left ventricular (LV) function undergoing CABG, focusing on the outcomes. Patients and Methods: This study enrolled 129 patients who underwent CABG with moderate to severe depressed LV function. Depending on the preoperative LV function, the patients were classified into two groups. Group I: n=49 cases who had their ejection fraction less than 35%, and it was subdivided into subgroups: (A) (n=26 who had preoperative IABP inserted for them) and (B) (n=23 who did not receive IABP preoperative). Group II: n=80 cases who had ejection fraction greater than or equal to 35%, and it was subdivided into subgroups (C) n=11 who received preoperative IABP and (D) (n=69 who did not receive preoperative IABP. Results: Morbidity, mortality rate, and incidence of complications showed significant improvement in patients who had IABP inserted for them compared with those who did not receive IABP preoperatively. In multivariant analysis, preoperative IABP was an independent risk factor for morbidity and mortality after CABG. Meanwhile, low platelet count was an independent risk factor for the development of complications (odds ratio: 0.975, 95% confidence interval: 0.956-0.993, P=0.007) and preoperative elevation of serum creatinine level was a significant risk factor for mortality (odds ratio: 1.007, 95% confidence interval: 1.000-1.014, P=0.050). Conclusion: Among patients who underwent CABG with moderately and severely impaired LV function, preoperative insertion of IABP improves postoperative outcome.
引用
收藏
页码:1435 / 1444
页数:10
相关论文
共 50 条
  • [31] Contemporary use and results of intra-aortic balloon pump counterpulsation
    Gargiulo, Giuseppe
    Stabile, Eugenio
    Perrino, Cinzia
    Scudiero, Fernando
    Scudiero, Laura
    Schiattarella, Gabriele G.
    Franzone, Anna
    Sannino, Anna
    Giugliano, Giuseppe
    Trimarco, Bruno
    Esposito, Giovanni
    MINERVA CARDIOANGIOLOGICA, 2016, 64 (01): : 84 - 91
  • [32] Analysis of intra-aortic balloon pump model with ovine myocardial infarction
    Abdolrazaghi, Mona
    Navidbakhsh, Mahdi
    Hassani, Kamran
    Rabbani, Shahram
    Ahmadi, Hossein
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2009, 9 (06) : 492 - 498
  • [33] Influence of intra-aortic balloon pump on mortality as a function of cardiogenic shock severity
    Jentzer, Jacob C.
    van Diepen, Sean
    Henry, Timothy D.
    Baran, David A.
    Barsness, Gregory W.
    Holmes, David R., Jr.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 (02) : 293 - 304
  • [34] Nicorandil Infusion During Off-Pump Coronary Artery Bypass Grafting Reduces Incidence of Intra-aortic Balloon Pump Insertion
    Saha, Kamales Kumar
    Kumar, Ajay
    Deval, Mandar Manohar
    Saha, Kakalee K.
    Jacob, Rinu V.
    Jagdale, Lukash
    Kaul, Shibban K.
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2016, 11 (02) : 123 - 127
  • [35] Predictors of intra-aortic balloon pump insertion in different spectrum of patients undergoing elective coronary artery bypass grafting
    Sahu M.K.
    Das A.
    Hote M.P.
    Rajashekar P.
    Sreenivas V.
    Airan B.
    Indian Journal of Thoracic and Cardiovascular Surgery, 2017, 33 (4) : 296 - 302
  • [36] Frequency of intra-aortic balloon pump insertion and associated factors in coronary artery bypass Grafting in a tertiary care hospital
    Ahmad, Imtiaz
    Ul Islam, Mujahid
    Rehman, Mujeeb Ur
    Khan, Bahauddin
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2021, 37 (02) : 393 - 397
  • [37] Intra-aortic balloon pump as a effecitve bridging therapy to coronary artery bypass grafting in a patient with myocardial infarction and recurrent pulmonary edema
    Sielski, Janusz
    Walek, Pawel
    Polewczyk, Anna
    Janion, Marianna
    KARDIOLOGIA POLSKA, 2010, 68 (01) : 85 - 89
  • [38] The role of the intra-aortic balloon pump counterpulsation (IABP) in emergency surgery
    Khan, AL
    Flett, M
    Yalamarthi, S
    Jeffrey, RR
    Ah-See, AK
    Park, KGM
    Keenan, RA
    SURGEON-JOURNAL OF THE ROYAL COLLEGES OF SURGEONS OF EDINBURGH AND IRELAND, 2003, 1 (05): : 279 - 282
  • [39] Intra-aortic balloon pump treatment for patients with acute anterior wall myocardial infarction after reperfusion therapy
    Feng, C. G.
    Yang, X. J.
    Fu, Q.
    Wang, Y. J.
    Ruan, H. Y.
    Lu, Y.
    Li, X. L.
    Zhang, X. P.
    GENETICS AND MOLECULAR RESEARCH, 2014, 13 (02) : 4280 - 4288
  • [40] Effect of peri-operative intra-aortic balloon pump in patients undergoing coronary artery bypass grafting on outcomes in a resource limited setting
    Sohail, Abdul Ahad
    Samejo, Areeba
    Bajwa, Hamza
    Wahab, Rida
    Asif, Narmeen
    Inam, Hina
    Shahabuddin, Syed
    PERFUSION-UK, 2024, 39 (07): : 1396 - 1404