Intrapartum monitoring of the fetal heart rate using transabdominal electrocardiography: A reliability and accuracy study

被引:0
|
作者
Wojtanowski, Anne [1 ,2 ]
Garabedian, Charles [2 ,3 ]
Charlier, Pierre [1 ,2 ]
Prot, Pierre [4 ]
Ghesquiere, Louise [2 ,3 ]
De Jonckheere, Julien [1 ,2 ]
机构
[1] CHU Lille, CIC IT 1403, F-59000 Lille, France
[2] Univ Lille, ULR 2694 METRICS, F-59000 Lille, France
[3] CHU Lille, Dept Obstet, F-59000 Lille, France
[4] BioSerenity, F-75013 Paris, France
关键词
Fetal heart rate monitoring; Non-invasive fetal electrocardiography; Signal quality; AUTONOMIC RESPONSE; RATE-VARIABILITY; LABOR;
D O I
10.1016/j.jogoh.2025.102942
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Introduction: In this study, we evaluated the performance of an intrapartum monitoring system (the TOCONAUTE) for fetal heart rate estimation using transabdominal electrocardiography. Method: This prospective study was conducted in Lille University Hospital's maternity ward between August 2022 and November 2023 to assess the performance of the TOCONAUTE compared to a cardiotocograph (CTG). Pregnant women in labor at 36 weeks or more of gestation with a singleton in cephalic presentation were eligible for enrollment in the study. In addition to the cardiotocograph, the participants received an abdominal electrode patch after providing their written informed consent. The positive percent agreement with the cardiotocograph indicated reliability, and the Bland-Altman analysis determined accuracy. Results: Of the 60 patient recruited, 35 patients were included in the recording analysis. The recordings had a mean duration of 519 f 210 min. The TOCONAUTE's fetal heart rate (FHR) overall positive percent of agreement (PPA) was 84.2 f 10.4 %. The PPA was greater than 80 % for all labor phases, except for expulsion (44.7 %). The overall mean bias was 1.7 f 2.4. For the FHR, the mean bias was lower than 2 bpm for all labor phases, except for expulsion (14.13 f 15.04 bpm). Conclusion: Compared with traditional CTG, this study demonstrated the TOCONAUTE's reliability and accuracy for FHR estimation in all labor phases except expulsion.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] ABDOMINAL ELECTROCARDIOGRAPHY IN INTRAPARTUM FETAL HEART-RATE MONITORING
    KARINIEMI, V
    ROSTI, J
    JOURNAL OF PERINATAL MEDICINE, 1986, 14 (04) : 263 - 266
  • [2] Fetal heart rate and maternal heart rate confusion during intrapartum monitoring: comparison of transabdominal fetal ECG and Doppler telemetry
    Signaroldi, Maria
    Mastroianni, Cristina
    Rosti, Eleonora
    Loi, Giorgia
    Di Francesco, Stefania
    Ferrazzi, Enrico
    Stampalija, Tamara
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2011, 204 : S261 - S262
  • [3] Intrapartum fetal heart rate monitoring
    不详
    OBSTETRICS AND GYNECOLOGY, 2005, 105 (05): : 1161 - 1168
  • [4] Intrapartum fetal heart rate monitoring
    Boehm, FH
    OBSTETRICS AND GYNECOLOGY CLINICS OF NORTH AMERICA, 1999, 26 (04) : 623 - +
  • [5] Intrapartum fetal heart rate monitoring
    van Geijn, HP
    Gynaecology, Obstetrics, and Reproductive Medicine in Daily Practice, 2005, 1279 : 332 - 337
  • [6] Reliability and agreement in intrapartum fetal heart rate monitoring interpretation: A systematic review
    Engelhart, Christina Hernandez
    Brurberg, Kjetil Gundro
    Aanstad, Kristin Jerve
    Pay, Aase Serine Devold
    Kaasen, Anne
    Blix, Ellen
    Vanbelle, Sophie
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2023, 102 (08) : 970 - 985
  • [7] The quality of intrapartum fetal heart rate monitoring
    Bakker, PCAM
    Colenbrander, GJ
    Verstraeten, AA
    Van Geijn, HP
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2004, 116 (01) : 22 - 27
  • [8] Intrapartum electronic fetal heart rate monitoring
    Antsaklis, A
    4TH WORLD CONGRESS OF PERINATAL MEDICINE, 1999, : 913 - 917
  • [9] Accuracy and reliability of fetal heart rate monitoring using maternal abdominal surface electrodes
    Cohen, Wayne R.
    Ommani, Sophia
    Hassan, Sarmina
    Mirza, Fadi G.
    Solomon, Molham
    Brown, Raymond
    Schifrin, Barry S.
    Himsworth, John M.
    Hayes-Gill, Barrie R.
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2012, 91 (11) : 1306 - 1313
  • [10] RELIABILITY OF INTRAPARTUM FETAL HEART-RATE MONITORING IN THE POSTTERM FETUS WITH MECONIUM PASSAGE
    SHAW, K
    CLARK, SL