Strength-duration curves for left bundle branch area pacing

被引:0
|
作者
Kielbasa, Grzegorz [1 ,2 ]
Jastrze, Marek [1 ,3 ]
Bednarek, Agnieszka [1 ,2 ]
Kusiak, Aleksander [1 ]
Sondej, Tomasz [1 ]
Bednarski, Adam [1 ]
Ostrowska, Aleksandra [1 ]
Zydzik, Lukasz [1 ]
Rajzer, Marek [1 ,2 ]
Vijayaraman, Pugazhendhi [1 ,4 ]
Moskal, Pawe
机构
[1] Jagiellonian Univ, Med Coll, Dept Cardiol Intervent Electrocardiol & Hypertens, Krakow, Poland
[2] Univ Hosp Krakow, Dept Cardiol Intervent Electrocardiol & Hypertens, Krakow, Poland
[3] Univ Hosp Krakow, Electrophysiol Lab, Krakow, Poland
[4] Geisinger Heart Inst, Wilkes Barre, PA USA
关键词
Left bundle branch area pacing; Chronaxie; Rheobase; Strength-duration curve; Battery consumption; STIMULATION;
D O I
10.1016/j.hrthm.2024.05.026
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Despite growing clinical use of left bundle branch pacing (LBBP), data regarding the fundamentals of this pacing modality, including chronaxie and rheobase, are scarce. OBJECTIVE The purpose of this study was to calculate strength-duration curves with chronaxie and rheobase values for LBBP and left ventricular septal pacing (LVSP), and to analyze battery current drain and presence of selective LBBP at very short pulse duration (PD). METHODS A group of 141 patients with permanent LBBP were studied. LBBP and LVSP capture thresholds were assessed at 6 different PDs to calculate the strength-duration curves. Battery current drain at these PDs and presence of selective LBBP were determined. For comparison of strength-duration curves between His-bundle pacing (HBP) and LBBP, source data from our previous work based on 127 patients with HBP were obtained. RESULTS The chronaxies for LBBP and LVSP were very similar (0.38 vs 0.39 ms), and the rheobases were identical (0.27 V). The chronaxie for LBBP was lower than for HBP (0.38 vs 0.53 ms; P <.001), whereas rheobases were similar (0.27 vs 0.26 V). A narrow zone of selective capture was present in 19% and 41% of patients at PD of 0.06 and 0.03 ms, respectively. When pacing with the safety margin of 1 1 V, the lowest battery current drain was achieved with PD of 0.2 ms. CONCLUSION The obtained strength-duration curves for LBBP and LVSP provide insights to optimal programming of left bundle branch area pacing devices with regard to PD, voltage amplitude, battery longevity, and selective capture.
引用
收藏
页码:2262 / 2269
页数:8
相关论文
共 50 条
  • [21] Left bundle branch area pacing guided by continuous uninterrupted monitoring of unipolar pacing characteristics
    Gillis, Kris
    O'Neill, Louisa
    Wielandts, Jean-Yves
    Hilfiker, Gabriela
    Vlase, Alina
    Knecht, Se'bastien
    Duytschaever, Mattias
    Tavernier, Rene'
    le Polain de Waroux, Jean-Benoit
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (02) : 299 - 307
  • [22] Left bundle branch area pacing delivery of cardiac resynchronization therapy and comparison with biventricular pacing
    Li, Xiaofei
    Qiu, Chunguang
    Xie, Ruiqin
    Ma, Wentao
    Wang, Zhao
    Li, Hui
    Wang, Hao
    Hua, Wei
    Zhang, Shu
    Yao, Yan
    Fan, Xiaohan
    ESC HEART FAILURE, 2020, 7 (04): : 1711 - 1722
  • [23] Left bundle branch area pacing with stylet-driven pacing leads: implantation technique
    Ga-In Yu
    Tae-Hoon Kim
    Hee Tae Yu
    Boyoung Joung
    Hui-Nam Pak
    Moon-Hyoung Lee
    International Journal of Arrhythmia, 24 (1)
  • [24] Possible systolic fascicular potentials in patients with left bundle branch block undergoing left bundle branch area pacing: A case series
    Coluccia, Giovanni
    Accogli, Michele
    Parlavecchio, Antonio
    Palmisano, Pietro
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (10) : 2108 - 2111
  • [25] Worldwide survey on implantation of and outcomes for conduction system pacing with His bundle and left bundle branch area pacing leads
    Perino, Alexander C.
    Wang, Paul J.
    Lloyd, Michael
    Zanon, Francesco
    Fujiu, Katsuhito
    Osman, Faizel
    Briongos-Figuero, Sem
    Sato, Toshiaki
    Aksu, Tolga
    Jastrzebski, Marek
    Sideris, Skevos
    Rao, Praveen
    Boczar, Krzysztof
    Xu Yuan-ning
    Wu, Michael
    Namboodiri, Narayanan
    Garcia, Rodrigue
    Kataria, Vikas
    De Pooter, Jan
    Przibille, Oliver
    Gehi, Anil K.
    Cano, Oscar
    Katsouras, Grigorios
    Cai, Binni
    Astheimer, Klaus
    Tanawuttiwat, Tanyanan
    Datino, Tomas
    Rizkallah, Jacques
    Alasti, Mohammad
    Feld, Gregory
    Barrio-Lopez, Maria Teresa
    Gilmore, Mark
    Conti, Sergio
    Yanagisawa, Satoshi
    Indik, Julia H.
    Zou, Jiangang
    Saha, Sandeep A.
    Rodriguez-Munoz, Daniel
    Chang, Kuan-Cheng
    Lebedev, Dmitry S.
    Leal, Miguel A.
    Haeberlin, Andreas
    Dal Forno, Alexander R. J.
    Orlov, Michael
    Frutos, Manuel
    Cabanas-Grandio, Pilar
    Lyne, Jonathan
    Leyva, Francisco
    Maria Tolosana, Jose
    Ollitrault, Pierre
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (07) : 1589 - 1600
  • [26] Clinical outcomes of left bundle branch area pacing: Prognosis and specific applications
    Yang, Zhen
    Liang, Jiadong
    Chen, Ruizhe
    Pang, Naidong
    Zhang, Nan
    Guo, Min
    Gao, Jia
    Wang, Rui
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, 47 (01): : 80 - 87
  • [27] The Emerging Role of Left Bundle Branch Area Pacing for Cardiac Resynchronisation Therapy
    Diaz, Juan Carlos
    Duque, Mauricio
    Aristizabal, Julian
    Marin, Jorge
    Nino, Cesar
    Bastidas, Oriana
    Ruiz, Luis Miguel
    Matos, Carlos
    Hoyos, Carolina
    Hincapie, Daniela
    Velasco, Alejandro
    Romero, Jorge E.
    ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2023, 12
  • [28] Septal Coronary Artery Fistula Following Left Bundle Branch Area Pacing
    De Pooter, Jan
    Calle, Simon
    Demulier, Laurent
    Timmermans, Frank
    Van Heuverswyn, Frederic
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2020, 6 (10) : 1337 - 1338
  • [29] Feasibility and safety of left bundle branch area pacing in patients with septal hypertrophy
    Ozpak, Emine
    Van Heuverswyn, Frederic
    Timmermans, Frank
    De Pooter, Jan
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (11) : 2255 - 2261
  • [30] Worldwide survey on implantation of and outcomes for conduction system pacing with His bundle and left bundle branch area pacing leads
    Alexander C. Perino
    Paul J. Wang
    Michael Lloyd
    Francesco Zanon
    Katsuhito Fujiu
    Faizel Osman
    Sem Briongos-Figuero
    Toshiaki Sato
    Tolga Aksu
    Marek Jastrzebski
    Skevos Sideris
    Praveen Rao
    Krzysztof Boczar
    Xu Yuan-ning
    Michael Wu
    Narayanan Namboodiri
    Rodrigue Garcia
    Vikas Kataria
    Jan De Pooter
    Oliver Przibille
    Anil K. Gehi
    Oscar Cano
    Grigorios Katsouras
    Binni Cai
    Klaus Astheimer
    Tanyanan Tanawuttiwat
    Tomas Datino
    Jacques Rizkallah
    Mohammad Alasti
    Gregory Feld
    Maria Teresa Barrio-Lopez
    Mark Gilmore
    Sergio Conti
    Satoshi Yanagisawa
    Julia H. Indik
    Jiangang Zou
    Sandeep A. Saha
    Daniel Rodriguez-Munoz
    Kuan-Cheng Chang
    Dmitry S. Lebedev
    Miguel A. Leal
    Andreas Haeberlin
    Alexander R. J. Dal Forno
    Michael Orlov
    Manuel Frutos
    Pilar Cabanas-Grandio
    Jonathan Lyne
    Francisco Leyva
    Jose Maria Tolosana
    Pierre Ollitrault
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 1589 - 1600