Investigation of the effect of crystal dead layer on system performance in Single Photon Emission Computed Tomography: A Monte Carlo simulation study

被引:0
作者
Aynur, Hilal Uslu [1 ]
Bayram, Tuncay [1 ,2 ]
Hayder, Anes [2 ,3 ]
Gedik, Sonay [2 ,4 ]
机构
[1] Karadeniz Tech Univ, Inst Hlth, Dept Hlth Phys, TR-61080 Trabzon, Turkiye
[2] Karadeniz Tech Univ, Fac Sci, Dept Phys, TR-61080 Trabzon, Turkiye
[3] Kufa Univ, Fac Sci, Dept Phys, Kufa 540011, Iraq
[4] Trabzon Kanuni Res & Training Hosp, Dept Nucl Med, Trabzon, Turkiye
关键词
SPECT; Dead layer; Scintillation crystal; Monte Carlo; OpenGATE; ENERGY; COLLIMATOR; GATE;
D O I
10.1016/j.radmeas.2024.107363
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
One of the factors affecting image quality in SPECT (Single Photon Emission Computed Tomography) applications is the dead layer that forms over time in the scintillation crystal. In this study, we aimed to investigate the effect of dead layers in the NaI(Tl) scintillation crystal used in SPECT on system performance. The GATE simulation code, which is based on the GEANT4 toolkit and is widely recognized for its application in nuclear imaging simulations, was employed for this investigation. In the first step, the standard SPECT model was simulated, and the SPECT performance parameters (sensitivity, spatial resolution, energy resolution, and contrast) for low 140 keV (for 99 m Tc), medium 167 keV (for201Tl), and high 364 keV (for131I) gamma energies have been analyzed. Then, various thicknesses of dead layers on the crystal were simulated, and the effect of the dead layer on the performance parameters was evaluated for the same energies. The results indicate reduction in SPECT sensitivity of approximately 33.5%, 27.1%, and 21.7% for low, medium, and high energies, respectively, as the thickness of the crystal's dead layer increases from 0.19 mm to 1.52 mm (equivalent to 2% to 16%). Small deteriorations in spatial resolution and energy resolution of the SPECT have been determined for 140 keV, 167 keV, and 364 keV gamma energies. The dead layers slightly influenced the contrast of SPECT. The results of this study show that the image quality assessment parameters of the SPECT system deteriorated as the thickness of the scintillation crystal's dead layer increased.
引用
收藏
页数:7
相关论文
共 39 条
[1]  
[Anonymous], 2009, IAEA Human Health Series No.1 Quality Assurance for PET and PET/CT Systems
[2]   Validation of the Monte Carlo simulator GATE for indium-111 imaging [J].
Assié, K ;
Gardin, I ;
Véra, P ;
Buvat, I .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (13) :3113-3125
[3]   Monte Carlo simulation in PET and SPECT instrumentation using GATE [J].
Assié, K ;
Breton, V ;
Buvat, I ;
Comtat, C ;
Jan, S ;
Krieguer, M ;
Lazaro, D ;
Morel, C ;
Rey, M ;
Santin, G ;
Simon, L ;
Staelens, S ;
Strul, D ;
Vieira, JM ;
Van de Walle, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (1-2) :180-189
[4]  
Cherry SR., 2012, Physics in Nuclear Medicine, DOI DOI 10.1016/B978-1-4160-5198-5.00015-0
[5]   Evaluation of a new multipurpose whole-body CzT-based camera: comparison with a dual-head Anger camera and first clinical images [J].
Desmonts, Cedric ;
Bouthiba, Mohammed Abdeldjalil ;
Enilorac, Blandine ;
Nganoa, Catherine ;
Agostini, Denis ;
Aide, Nicolas .
EJNMMI PHYSICS, 2020, 7 (01)
[6]   Clinical quantitative cardiac imaging for the assessment of myocardial ischaemia [J].
Dewey, Marc ;
Siebes, Maria ;
Kachelriess, Marc ;
Kofoed, Klaus F. ;
Maurovich-Horvat, Pal ;
Nikolaou, Konstantin ;
Bai, Wenjia ;
Kofler, Andreas ;
Manka, Robert ;
Kozerke, Sebastian ;
Chiribiri, Amedeo ;
Schaeffter, Tobias ;
Michallek, Florian ;
Bengel, Frank ;
Nekolla, Stephan ;
Knaapen, Paul ;
Lubberink, Mark ;
Senior, Roxy ;
Tang, Meng-Xing ;
Piek, Jan J. ;
van de Hoef, Tim ;
Martens, Johannes ;
Schreiber, Laura .
NATURE REVIEWS CARDIOLOGY, 2020, 17 (07) :427-450
[7]  
Goodman N. B., 1976, Space Science Instrumentation, V2, P425
[8]   Large-Area SiPM Pixels (LASiPs): A cost-effective solution towards compact large SPECT cameras [J].
Guberman, D. ;
Paoletti, R. ;
Rugliancich, A. ;
Wunderlich, C. ;
Passeri, A. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 82 :171-184
[9]   The effect of energy and source location on gamma camera intrinsic and extrinsic spatial resolution: an experimental and Monte Carlo study [J].
Holstensson, Maria ;
Partridge, Mike ;
Buckley, Susan E. ;
Flux, Glenn D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (06) :1735-1751
[10]   EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras [J].
Hyafil, Fabien ;
Gimelli, Alessia ;
Slart, Riemer H. J. A. ;
Georgoulias, Panagiotis ;
Rischpler, Christoph ;
Lubberink, Mark ;
Sciagra, Roberto ;
Bucerius, Jan ;
Agostini, Denis ;
Verberne, Hein J. .
EUROPEAN JOURNAL OF HYBRID IMAGING, 2019, 3 (01)