BIOMECHANICAL EVALUATION OF POLYAXIAL ANGULAR STABLE PLATES IN THE MANAGEMENT OF TIBIAL PLATEAU FRACTURES

被引:0
|
作者
Forna, Norin [1 ,2 ]
Sirbu, Paul-Dan [1 ,2 ]
Liliana, Savin [1 ,2 ]
Eva, Lucian [3 ,4 ]
Friedl, Wilhelm [5 ]
Carata, Eugen [6 ]
Pinteala, Tudor [1 ,2 ]
Tudor, Razvan [1 ,7 ]
Sirbu, Mihnea Theodor [1 ]
机构
[1] Grigore T Popa Univ Med & Pharm, Fac Med, Dept Orthoped & Traumatol, Iasi 700115, Romania
[2] Clin Rehabil Hosp, Dept Orthoped, Iasi 700661, Romania
[3] Prof Dr Nicolae Oblu Neurosurg Hosp Iasi, 2 Ateneului, Iasi 700309, Romania
[4] Dunarea de Jos Univ Galati, Fac Med, Galati 800008, Romania
[5] Wertheim Hosp, Dept Orthoped & Traumatol, D-97877 Wertheim, Germany
[6] Gheorghe Asachi Tech Univ, Fac Machine Construct & Ind Management, Dept Machine Tools & Equipment, Iasi 700050, Romania
[7] Iacob Czihac Emergency Mil Clin Hosp, Dept Orthoped & Traumatol, 7-9 Gen Henri Mathias Berthelot St, Iasi 700483, Romania
来源
ROMANIAN JOURNAL OF ORAL REHABILITATION | 2024年 / 16卷 / 04期
关键词
osteosynthesis; biomechanical performance; polyaxial; tibial plateau fractures; axial loading; stiffness; stability; lateral plate; medial plate; LATERAL LOCKING PLATE; METAANALYSIS SHOWS; SIMILAR OUTCOMES; ALIGNMENT; FIXATION; TITANIUM; STRESS; ANGLE;
D O I
10.62610/RJOR.2024.4.16.52
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Biomechanical efficacy is critical in managing tibial plateau fractures. This study compared the performance of polyaxial screw-plate implant systems under axial loading conditions using synthetic bone models. Osteosynthesis methods involving lateral, medial, and combined (lateral + medial) plates were evaluated. Although no statistically significant differences in stiffness and stability were observed across all groups under progressive axial loading, the combined lateral and medial plate technique demonstrated superior biomechanical performance compared to individual plate use. Notably, the lateral plate method outperformed the medial plate approach but was surpassed by the dual plate configuration. A statistically significant, directly proportional relationship between time intervals and displacement, along with an inverse correlation between time intervals and stiffness, was observed across all test groups. These findings highlight that combining lateral and medial plates enhances rigidity and stability, particularly under axial loading, making it a preferred approach for treating tibial plateau fractures.
引用
收藏
页码:537 / 550
页数:14
相关论文
共 50 条
  • [31] Biomechanical comparisons of plate placement for medial tibial plateau fractures (Schatzker type IV): A biomechanical study using porcine tibias
    Ando, Jiro
    Takahashi, Tsuneari
    Matsumura, Tomohiro
    Nibe, Yoshiya
    Takeshita, Katsushi
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (06):
  • [32] Biomechanical Evaluation of Two-Part Surgical Neck Fractures of the Humerus Fixed by an Angular Stable Locked Intramedullary Nail
    Horn, Joachim
    Gueorguiev, Boyko
    Brianza, Stefano
    Steen, Harald
    Schwieger, Karsten
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (07) : 406 - 413
  • [33] Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty: plates versus cannulated screws
    Seeger, Joern Bengt
    Jaeger, S.
    Roehner, E.
    Dierkes, H.
    Wassilew, G.
    Clarius, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (02) : 253 - 257
  • [34] Schatzker II tibial plateau fractures: Anatomically precontoured locking compression plates seem to improve radiological and clinical outcomes
    Prall, W. C.
    Rieger, M.
    Fuermetz, J.
    Haasters, F.
    Mayr, H. O.
    Boecker, W.
    Kusmenkov, T.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (10): : 2295 - 2301
  • [35] Biomechanical Evaluation of a Fin-type Implant Compared to Traditional Buttress Plate for the Stabilization of the Posteromedial Fragment in Tibial Plateau Split Fractures
    Chen, Jian-Chih
    Lin, Kang-Ping
    Lee, Tien-Ching
    Fu, Yin-Chih
    Lin, Kun-Jhih
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2021, 41 (05) : 742 - 749
  • [36] Influence of reduction accuracy in lateral tibial plateau fractures on intra-articular friction - a biomechanical study
    Walter, Christian
    Beck, Alexander
    Jacob, Christopher
    Hofmann, Ulf Krister
    Stoeckle, Ulrich
    Stuby, Fabian
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [37] The "Flexor Carpi Radialis" Approach to the Knee for the Management of Posterior Tibial Plateau Fractures
    Watson, J. Tracy
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (06) : E225 - E226
  • [38] Biomechanical aspects of the posteromedial split in bicondylar tibial plateau fractures-a finite-element investigation
    Dehoust, J.
    Muench, M.
    Seide, K.
    Barth, T.
    Frosch, K. -H.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2020, 46 (06) : 1257 - 1266
  • [39] Indirect reduction and hybrid external fixation in management of comminuted tibial plateau fractures
    El-Alfy, Barakat
    Othman, Abdulsalam
    Mansour, Emad
    ACTA ORTHOPAEDICA BELGICA, 2011, 77 (03): : 349 - 354
  • [40] Complications in the management of closed high-energy proximal tibial plateau fractures
    Khatri, Kavin
    Sharma, Vijay
    Goyal, Darsh
    Farooque, Kamran
    CHINESE JOURNAL OF TRAUMATOLOGY, 2016, 19 (06) : 342 - 347