BIOMECHANICAL EVALUATION OF POLYAXIAL ANGULAR STABLE PLATES IN THE MANAGEMENT OF TIBIAL PLATEAU FRACTURES

被引:0
|
作者
Forna, Norin [1 ,2 ]
Sirbu, Paul-Dan [1 ,2 ]
Liliana, Savin [1 ,2 ]
Eva, Lucian [3 ,4 ]
Friedl, Wilhelm [5 ]
Carata, Eugen [6 ]
Pinteala, Tudor [1 ,2 ]
Tudor, Razvan [1 ,7 ]
Sirbu, Mihnea Theodor [1 ]
机构
[1] Grigore T Popa Univ Med & Pharm, Fac Med, Dept Orthoped & Traumatol, Iasi 700115, Romania
[2] Clin Rehabil Hosp, Dept Orthoped, Iasi 700661, Romania
[3] Prof Dr Nicolae Oblu Neurosurg Hosp Iasi, 2 Ateneului, Iasi 700309, Romania
[4] Dunarea de Jos Univ Galati, Fac Med, Galati 800008, Romania
[5] Wertheim Hosp, Dept Orthoped & Traumatol, D-97877 Wertheim, Germany
[6] Gheorghe Asachi Tech Univ, Fac Machine Construct & Ind Management, Dept Machine Tools & Equipment, Iasi 700050, Romania
[7] Iacob Czihac Emergency Mil Clin Hosp, Dept Orthoped & Traumatol, 7-9 Gen Henri Mathias Berthelot St, Iasi 700483, Romania
来源
ROMANIAN JOURNAL OF ORAL REHABILITATION | 2024年 / 16卷 / 04期
关键词
osteosynthesis; biomechanical performance; polyaxial; tibial plateau fractures; axial loading; stiffness; stability; lateral plate; medial plate; LATERAL LOCKING PLATE; METAANALYSIS SHOWS; SIMILAR OUTCOMES; ALIGNMENT; FIXATION; TITANIUM; STRESS; ANGLE;
D O I
10.62610/RJOR.2024.4.16.52
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Biomechanical efficacy is critical in managing tibial plateau fractures. This study compared the performance of polyaxial screw-plate implant systems under axial loading conditions using synthetic bone models. Osteosynthesis methods involving lateral, medial, and combined (lateral + medial) plates were evaluated. Although no statistically significant differences in stiffness and stability were observed across all groups under progressive axial loading, the combined lateral and medial plate technique demonstrated superior biomechanical performance compared to individual plate use. Notably, the lateral plate method outperformed the medial plate approach but was surpassed by the dual plate configuration. A statistically significant, directly proportional relationship between time intervals and displacement, along with an inverse correlation between time intervals and stiffness, was observed across all test groups. These findings highlight that combining lateral and medial plates enhances rigidity and stability, particularly under axial loading, making it a preferred approach for treating tibial plateau fractures.
引用
收藏
页码:537 / 550
页数:14
相关论文
共 50 条
  • [21] A Novel Approach in the Management of Tibial Plateau Fractures with Compartment Syndrome
    P. Madhuchandra
    S. Muthukumar Balaji
    Indian Journal of Orthopaedics, 2023, 57 : 1435 - 1442
  • [22] Current management of high-energy Tibial plateau fractures
    Zura, Robert D.
    Browne, James A.
    Black, Molly D.
    Olson, Steven A.
    CURRENT ORTHOPAEDICS, 2007, 21 (03): : 229 - 235
  • [23] Conservative Management of Varus/Valgus Stable Tibial Plateau Fractures in Osteoporotic Bone-Preliminary Results and Considerations
    Lim, Jiang An
    West, Cavan
    Lim, Jiang Rong
    Thahir, Azeem
    Krkovic, Matija
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2023, 11 (04): : 269 - 276
  • [24] Evaluation of the Effectiveness of the Angular Stable Locking System in Patients with Distal Tibial Fractures Treated with Intramedullary Nailing A Multicenter Randomized Controlled Trial
    Hoentzsch, Dankward
    Schaser, Klaus-Dieter
    Hofmann, Gunther O.
    Pohlemann, Tim
    Hem, Einar Sturla
    Rothenbach, Erik
    Krettek, Christian
    Attal, Rene
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (22) : 1889 - 1897
  • [25] Ex vivo biomechanical evaluation of a bone-screw-fastener for tibial plateau leveling osteotomy
    Kettleman, William S. S.
    Jaffe, Michael H. H.
    Wills, Robert W. W.
    Dietz, Sara J. J.
    Elder, Steve H. H.
    FRONTIERS IN VETERINARY SCIENCE, 2023, 10
  • [26] Newly designed anterolateral and posterolateral locking anatomic plates for lateral tibial plateau fractures: a finite element study
    Chen, Pengbo
    Lu, Hua
    Shen, Hao
    Wang, Wei
    Ni, Binbin
    Chen, Jishizhan
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
  • [27] Biomechanical comparison of intramedullar versus extramedullar stabilization of intra-articular tibial plateau fractures
    Hoegel, Florian
    Hoffmann, Stefanie
    Panzer, Stefanie
    Wimber, Johannes
    Buehren, Volker
    Augat, Peter
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (01) : 59 - 64
  • [28] Impact of screw reinsertion on osteosynthesis stability in Schatzker IV tibial plateau fractures: a biomechanical study
    Hiyama, Shuhei
    Takahashi, Tsuneari
    Ando, Jiro
    Nibe, Yoshiya
    Matsumura, Tomohiro
    Takeshita, Katsushi
    SICOT-J, 2025, 11
  • [29] Biomechanical aspects of the posteromedial split in bicondylar tibial plateau fractures—a finite-element investigation
    J. Dehoust
    M. Münch
    K. Seide
    T. Barth
    K.-H. Frosch
    European Journal of Trauma and Emergency Surgery, 2020, 46 : 1257 - 1266
  • [30] Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty: plates versus cannulated screws
    Joern Bengt Seeger
    S. Jaeger
    E. Röhner
    H. Dierkes
    G. Wassilew
    M. Clarius
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 253 - 257