The temporal inverted internal limiting membrane flap technique versus multilayered inverted flap technique in patients with idiopathic macular hole

被引:0
|
作者
Elgouhary, Sameh M. [1 ]
Abd-elmoaty, Safaa M. [2 ]
Salama, Ahmed A. [1 ]
机构
[1] Menoufia Univ, Dept Ophthalmol, Menoufia, Egypt
[2] Elsadat Cent Hosp, Dept Ophthalmol, Menoufia, Egypt
关键词
internal limiting membrane peeling; inverted flaps; macular hole; optical coherence tomography; RESTORATION;
D O I
10.4103/ejos.ejos_46_24
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
ObjectivesThis study aimed to compare the temporal inverted internal limiting membrane (ILM) flap technique with the multilayered inverted ILM flap technique for treating idiopathic macular holes (IMHs) by assessing anatomical outcomes using optical coherence tomography (OCT) and functional outcomes through best corrected visual acuity (BCVA) and optical coherence tomography angiography (OCTA).BackgroundILM flaps act as a scaffold that promotes macular hole closure by facilitating cell proliferation and migration.Patients and methodsPatients with IMHs were divided into two groups. Group A underwent the temporal inverted ILM flap technique, while group B received the multilayered inverted ILM flap technique. Preoperative assessment of BCVA, OCT and OCTA. Follow-up at 1, 3, and 6 months by OCT and assessment of BCVA, and OCTA at 3 months.ResultsThe study included 20 eyes with IMH: group A (mean age 60.9 +/- 4.51 years) and group B (mean age 62.7 +/- 3.74 years). Postoperative OCT revealed no significant differences in closure patterns between the groups. Group A had 60% type U, 10% type V, and 20% type W closure patterns, with 10% of cases failing to close. Group B had 70% type U, 20% type V, and 10% type W closure patterns. BCVA improved from 0.06 +/- 0.02 to 0.24 +/- 0.14 in group A and from 0.05 +/- 0.02 to 0.30 +/- 0.11 in group B.ConclusionWhile no significant anatomical differences were observed between the two techniques, the multilayered inverted ILM flap technique demonstrated superior functional outcomes compared with the temporal flap technique.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 50 条
  • [31] Macular microvasculature differences in patients with macular hole after vitrectomy with internal limiting membrane removal or single-layered temporal inverted flap technique
    Karalezli, Aylin
    Kaderli, Sema Tamer
    Sul, Sabahattin
    EYE, 2021, 35 (10) : 2746 - 2753
  • [32] Modification of the inverted flap technique compared to conventional internal limiting membrane peeling in complete macular hole surgery
    Carballes, M. J. Crespo
    Sastre-Ibanez, M.
    Del Cura, M. Prieto
    De Hoz, R.
    Garcia-Saenz, M. C.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (06) : 2275 - 2284
  • [33] INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE FOR TREATMENT OF MACULAR HOLE RETINAL DETACHMENT IN HIGHLY MYOPIC EYES
    Takahashi, Hiroyuki
    Inoue, Makoto
    Koto, Takashi
    Itoh, Yuji
    Hirota, Kazunari
    Hirakata, Akito
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2018, 38 (12): : 2317 - 2326
  • [34] Conventional internal limiting membrane peeling versus temporal inverted internal limiting membrane flap for large macular holes
    Avci, Remzi
    Yildiz, Aysegul Mavi
    Yilmaz, Sami
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (02) : 679 - 687
  • [35] Inverted Internal Limiting Membrane Flap versus Internal Limiting Membrane Insertion Technique for Large Macular Holes: A Meta-Analysis
    Li, Shuang
    Zhang, Lu
    Yu, Ji-Guo
    SEMINARS IN OPHTHALMOLOGY, 2023, 38 (08) : 752 - 760
  • [36] Evaluation of inner retinal dimples and internal limiting membrane flap configuration after temporal inverted ILM flap technique
    Avci, Remzi
    Mavi Yildiz, Aysegul
    Yilmaz, Sami
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (02) : 649 - 655
  • [37] The Flip and Fix internal limiting flap technique versus the classic temporal flap for macular hole repair
    Shousha, Mohsen Abou
    Lolah, Mohamed M.
    Ahmed, Islam S. H.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (SUPPL 5) : S852 - S857
  • [38] Modification of the Inverted Internal Limiting Membrane Flap Technique for the Treatment of Chronic and Large Macular Holes
    Andrew, Nicholas
    Chan, Weng Onn
    Tan, Mei
    Ebneter, Andreas
    Gilhotra, Jagjit Singh
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (04): : 834 - 837
  • [39] EARLY AND LATE MACULAR CHANGES AFTER THE INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE FOR A FULL-THICKNESS MACULAR HOLE
    Tsui, Mei-Chi
    Yang, Chung-May
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2021, 41 (01): : 20 - 28
  • [40] Inverted internal limiting membrane-flap technique to treat a full-thickness macular hole complicating idiopathic macular telangiectasia type 2
    Sborgia, Giancarlo
    Niro, Alfredo
    Coassin, Marco
    Sborgia, Luigi
    D'Oria, Francesco
    Pastore, Valentina
    Albano, Valeria
    Trittol, Tiziana
    Sborgia, Alessandra
    Boscia, Francesco
    Alessio, Giovanni
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (02) : NP81 - NP85