Dedicated Photon-Counting CT for Detection and Classification of Microcalcifications: An Intraindividual Comparison With Digital Breast Tomosynthesis

被引:0
|
作者
Huck, Luisa Charlotte [1 ]
Bode, Maike [1 ]
Zanderigo, Eloisa [1 ]
Wilpert, Caroline [1 ,2 ]
Raaff, Vanessa [1 ]
Dethlefsen, Ebba [1 ]
Wenkel, Evelyn [3 ,4 ]
Kuhl, Christiane Katharina [1 ]
机构
[1] Univ Hosp Aachen, Dept Diagnost & Intervent Radiol, Dept Radiol, Pauwelsstr 30, D-52074 Aachen, Germany
[2] Univ Hosp Freiburg, Dept Diagnost & Intervent Radiol, Freiburg, Germany
[3] Univ Hosp Erlangen, Dept Radiol, Erlangen, Germany
[4] Radiol Munchen, Dept Radiol, Munich, Germany
关键词
photon-counting breast CT; dedicated breast CT; tomosynthesis; microcalcifications; breast cancer; SCREEN-FILM MAMMOGRAPHY; COMPUTED-TOMOGRAPHY; DENSE BREASTS; IMAGE QUALITY; WOMEN; MRI; PERFORMANCE; EXPERIENCES;
D O I
10.1097/RLI.0000000000001097
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Clinical experience regarding the use of dedicated photon-counting breast CT (PC-BCT) for diagnosis of breast microcalcifications is scarce. This study systematically compares the detection and classification of breast microcalcifications using a dedicated breast photon-counting CT, especially designed for examining the breast, in comparison with digital breast tomosynthesis (DBT). Materials and Methods This is a prospective intraindividual study on women with DBT screening-detected BI-RADS-4/-5 microcalcifications who underwent PC-BCT before biopsy. PC-BCT images were reconstructed with a noninterpolated spatial resolution of 0.15 x 0.15 x 0.15 mm (reconstruction mode 1 [RM-1]) and with 0.3 x 0.3 x 0.3 mm (reconstruction mode 2 [RM-2]), plus thin-slab maximum intensity projection (MIP) reconstructions. Two radiologists independently rated the detection of microcalcifications in direct comparison with DBT on a 5-point scale. The distribution and morphology of microcalcifications were then rated according to BI-RADS. The size of the smallest discernible microcalcification particle was measured. For PC-BCT, the average glandular dose was determined by Monte Carlo simulations; for DBT, the information provided by the DBT system was used. Results Between September 2022 and July 2023, 22 participants (mean age, 61; range, 42-85 years) with microcalcifications (16 malignant; 6 benign) were included. In 2/22 with microcalcifications in the posterior region, microcalcifications were not detectable on PC-BCT, likely because they were not included in the PC-BCT volume. In the remaining 20 participants, microcalcifications were detectable. With high between-reader agreement (kappa > 0.8), conspicuity of microcalcifications was rated similar for DBT and MIPs of RM-1 (mean, 4.83 +/- 0.38 vs 4.86 +/- 0.35) (P = 0.66), but was significantly lower (P < 0.05) for the remaining PC-BCT reconstructions: 2.11 +/- 0.92 (RM-2), 2.64 +/- 0.80 (MIPs of RM-2), and 3.50 +/- 1.23 (RM-1). Identical distribution qualifiers were assigned for PC-BCT and DBT in 18/20 participants, with excellent agreement (kappa = 0.91), whereas identical morphologic qualifiers were assigned in only 5/20, with poor agreement (kappa = 0.44). The median size of smallest discernible microcalcification particle was 0.2 versus 0.6 versus 1.1 mm in DBT versus RM-1 versus RM-2 (P < 0.001), likely due to blooming effects. Average glandular dose was 7.04 mGy (PC-BCT) versus 6.88 mGy (DBT) (P = 0.67). Conclusions PC-BCT allows reliable detection of in-breast microcalcifications as long as they are not located in the posterior part of the breast and allows assessment of their distribution, but not of their individual morphology.
引用
收藏
页码:838 / 844
页数:7
相关论文
共 50 条
  • [1] Radiomics in photon-counting dedicated breast CT: potential of texture analysis for breast density classification
    Landsmann, Anna
    Ruppert, Carlotta
    Wieler, Jann
    Hejduk, Patryk
    Ciritsis, Alexander
    Borkowski, Karol
    Wurnig, Moritz C.
    Rossi, Cristina
    Boss, Andreas
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2022, 6 (01)
  • [2] Evaluation of photon-counting spectral mammography for classification of breast microcalcifications
    Kim, Hyemi
    Lee, Minjae
    Kim, Dohyeon
    Lee, Donghoon
    Kim, Hee-Joung
    RADIATION PHYSICS AND CHEMISTRY, 2019, 162 : 39 - 47
  • [3] Detection of microcalcifications in photon-counting dedicated breast-CT using a deep convolutional neural network: Proof of principle
    Landsmann, Anna
    Ruppert, Carlotta
    Borkowski, Karol
    Hejduk, Patryk
    Ciritsis, Alexander
    Wieler, Jann
    Rossi, Cristina
    Boss, Andreas
    CLINICAL IMAGING, 2023, 95 : 28 - 36
  • [4] Characterization of photon-counting multislit breast tomosynthesis
    Berggren, Karl
    Cederstrom, Bjorn
    Lundqvist, Mats
    Fredenberg, Erik
    MEDICAL PHYSICS, 2018, 45 (02) : 549 - 560
  • [5] Detection of Microcalcifications in Spiral Breast Computed Tomography with Photon-Counting Detector Is Feasible: A Specimen Study
    Wetzl, Matthias
    Wenkel, Evelyn
    Balbach, Eva
    Dethlefsen, Ebba
    Hartmann, Arndt
    Emons, Julius
    Kuhl, Christiane
    Beckmann, Matthias W.
    Uder, Michael
    Ohlmeyer, Sabine
    DIAGNOSTICS, 2021, 11 (05)
  • [6] Evaluation of photon-counting spectral breast tomosynthesis
    Dahlman, Nils
    Fredenberg, Erik
    Aslund, Magnus
    Lundqvist, Mats
    Diekmann, Felix
    Danielsson, Mats
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [7] Performance of photon-counting and energy-integrating semiconductor detectors for digital breast tomosynthesis
    Myronakis, Marios E.
    Darambara, Dimitra G.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1488 - 1490
  • [8] Clinical experience of photon counting breast tomosynthesis: comparison with traditional mammography
    Svane, Gunilla
    Azavedo, Edward
    Lindman, Karin
    Urech, Mattias
    Nilsson, Jonas
    Weber, Niclas
    Lindqvist, Lars
    Ullberg, Christer
    ACTA RADIOLOGICA, 2011, 52 (02) : 134 - 142
  • [9] The effect of angular dose distribution on the detection of microcalcifications in digital breast tomosynthesis
    Hu, Yue-Houng
    Zhao, Wei
    MEDICAL PHYSICS, 2011, 38 (05) : 2455 - 2466
  • [10] Dedicated Breast Computed Tomography With a Photon-Counting Detector Initial Results of Clinical In Vivo Imaging
    Berger, Nicole
    Marcon, Magda
    Saltybaeva, Natalia
    Kalender, Willi A.
    Alkadhi, Hatem
    Frauenfelder, Thomas
    Boss, Andreas
    INVESTIGATIVE RADIOLOGY, 2019, 54 (07) : 409 - 418