Very High-Power Short-Duration Ablation for Atrial Fibrillation in Adults With Congenital Heart Disease

被引:0
|
作者
Lengauer, Sarah [1 ]
Erhard, Nico [1 ]
Popa, Miruna A. [1 ]
Telishevska, Marta [1 ]
Krafft, Hannah [1 ]
Bahlke, Fabian [1 ]
Englert, Florian [1 ]
Bourier, Felix [1 ]
Reents, Tilko [1 ]
Deisenhofer, Isabel [1 ]
Hessling, Gabriele [1 ]
机构
[1] TUM Univ Hosp, German Heart Ctr Munich, Dept Electrophysiol, Munich, Bavaria, Germany
关键词
adults with congenital heart disease; long-term outcome; paroxysmal and persistent atrial fibrillation; safety; very high-power short duration ablation; PULMONARY VEIN ISOLATION; CATHETER ABLATION; ARRHYTHMIAS; PREVALENCE; SAFETY;
D O I
10.1111/jce.16567
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionData regarding safety and long-term outcome of very high-power-short duration (vHPSD) ablation in adult congenital heart disease (ACHD) patients with paroxysmal or persistent atrial fibrillation (AF) are lacking.MethodsRetrospective observational single-center study. The data of 66 consecutive ACHD patients (mean age 60 +/- 12.8 years, 46% male) with mild (69.7%), moderate (22.7%), or complex (7.6%) congenital heart disease (CHD) who underwent ablation for paroxysmal (40.9%) or persistent AF (59.1%) were analyzed. Circumferential PVI was performed in all patients and additional substrate ablation in 79,4% of persistent AF patients using irrigated RF energy with vHPSD settings of 70 W/5-7 s or 60 W/7-10 s.ResultsMean procedure time was 123.6 +/- 42 min with a mean RF time of 18.19 +/- 10 min. No technique related adverse events occurred. Vascular access complications were detected in seven patients (10.6%) requiring intervention in four patients (6%). A median follow-up time of 491 days (IQR: 194-1054 days). Freedom from any atrial arrhythmia off antiarrhythmic drugs (AAD) at 1 year was present in 58% of patients (77.8% with paroxysmal AF, 43.6% with persistent AF).ConclusionvHPSD for ablation of paroxysmal or persistent AF in ACHD patients is safe and effective. Regardless of CHD complexity, no vHPSD ablation modality related complications occurred. Long-term outcome for paroxysmal AF after one ablation was excellent whereas results for persistent AF were limited.
引用
收藏
页码:625 / 631
页数:7
相关论文
共 50 条
  • [31] With Great Power Comes Great Responsibility: Defining the Safety of High-Power Short-Duration Atrial Ablation
    Sauer, William H.
    Tzou, Wendy S.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2019, 12 (06)
  • [32] The superiority of high-power short-duration radiofrequency catheter ablation strategy for atrial fibrillation treatment: A systematic review and meta-analysis study
    Waranugraha, Yoga
    Rizal, Ardian
    Firdaus, Achmad J.
    Sihotang, Fransiska A.
    Akbar, Akita R.
    Lestari, Defyna D.
    Firdaus, Muhammad
    Nurudinulloh, Akhmad I.
    JOURNAL OF ARRHYTHMIA, 2021, 37 (04) : 975 - 989
  • [33] Triple gastrointestinal prophylactic therapy following high-power short-duration posterior left atrial wall ablation
    Candemir, Basar
    Baskovski, Emir
    Mammadov, Mammad
    Esenboga, Kerim
    Altin, Timucin
    INDIAN HEART JOURNAL, 2020, 72 (04) : 306 - 308
  • [34] Atrial fibrillation ablation workflow optimization facilitated by high-power short-duration ablation and high-resolution mapping
    Fink, Thomas
    Sciacca, Vanessa
    Nischik, Flemming
    Bergau, Leonard
    Guckel, Denise
    El Hamriti, Mustapha
    Khalaph, Moneeb
    Braun, Martin
    Winnik, Stephan
    Didenko, Maxim
    Imnadze, Guram
    Sommer, Philipp
    Sohns, Christian
    EUROPACE, 2024, 26 (03):
  • [35] Combined approach of high-power and very high-power, short-duration ablation in superior vena cava isolation
    Makita, Toshio
    Kuwahara, Taishi
    Takahashi, Kenta
    Oshio, Takuya
    Kadono, Kenta
    Oyagi, Yoshimi
    Ito, Yayoi
    Takahashi, Ryo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (11) : 2144 - 2152
  • [36] Safety and outcome of very if high-power short-duration ablation using 70 W for pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Kottmaier, Marc
    Popa, Miruna
    Bourier, Felix
    Reents, Tilko
    Cifuentes, Jairo
    Semmler, Verena
    Telishevska, Martha
    Otgonbayar, Ulamnemekh
    Koch-Buettner, Katharina
    Lennerz, Carsten
    Bartkowiak, Marcin
    Kornmayer, Marielouise
    Rousseva, Elena
    Brkic, Amir
    Grebmer, Christian
    Kolb, Christoph
    Hessling, Gabriele
    Deisenhofer, Isabel
    EUROPACE, 2020, 22 (03): : 388 - 393
  • [37] Next-generation atrial fibrillation ablation: clinical performance of pulsed-field ablation and very high-power short-duration radiofrequency
    Soubh, Nibras
    Gronwald, Judith
    Haarmann, Helge
    Rasenack, Eva
    Bengel, Philipp
    Schloegl, Simon
    Hasenfuss, Gerd
    Zabel, Markus
    Bergau, Leonard
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, : 2067 - 2075
  • [38] High-power short-duration versus standard-power standard-duration settings for repeat atrial fibrillation ablation
    Joey Junarta
    Sean J. Dikdan
    Naman Upadhyay
    Sairamya Bodempudi
    Michael Y. Shvili
    Daniel R. Frisch
    Heart and Vessels, 2022, 37 : 1003 - 1009
  • [39] Recovery of Conduction Following High-Power Short-Duration Ablation in Patients With Atrial Fibrillation A Single-Center Experience
    Mohanty, Sanghamitra
    Trivedi, Chintan
    Della Rocca, Domenico G.
    Gianni, Carola
    MacDonald, Bryan
    Quintero Mayedo, Angel
    Al-Ahmad, Amin
    Burkhardt, John D.
    Bassiouny, Mohamed
    Gallinghouse, G. Joseph
    Horton, Rodney
    Di Biase, Luigi
    Natale, Andrea
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2021, 14 (10) : E010096
  • [40] Impact of high-power short-duration atrial fibrillation ablation technique on the incidence of silent cerebral embolism: a prospective randomized controlled study
    Chen, Wei-Jie
    Gan, Chun-Xia
    Cai, Yang-Wei
    Liu, Yang-Yang
    Xiao, Pei-Lin
    Zou, Li-Li
    Xiong, Qing-Song
    Qin, Fang
    Tao, Xie-Xin
    Li, Ran
    Du, Hua-An
    Liu, Zeng-Zhang
    Yin, Yue-Hui
    Ling, Zhi-Yu
    BMC MEDICINE, 2023, 21 (01)