Biomechanical analysis of partial mandibular implants with various lattice designs of different material properties: In vitro study and finite element analysis

被引:0
|
作者
Zhang, Hao [1 ]
Fuh, Lih Jyh [1 ,2 ]
Hsu, Jui Ting [3 ]
Lim, Zhe Min [1 ]
Huang, Heng Li [1 ,4 ]
机构
[1] China Med Univ, Sch Dent, Taichung, Taiwan
[2] China Med Univ Hosp, Dept Dent, Taichung, Taiwan
[3] China Med Univ, Dept Biomed Engn, Taichung, Taiwan
[4] Asia Univ, Dept Bioinformat & Med Engn, Taichung, Taiwan
关键词
Mandibular segmental resection; Porous lattice design; Lattice size; Rod diameter; Mandibular implant; Abutment; In vitro experiment; Finite element analysis; PORE-SIZE; RECONSTRUCTION; BONE; PROSTHESIS; STRESS;
D O I
10.36922/ijb.3943
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For patients with mandibular bone defects, although reconstruction plates can be used for repair, achieving both occlusal function and facial aesthetics is challenging. In the present study, in vitro experiments and finite element analysis (FEA) were conducted to determine the biomechanical characteristics of multiple porous lattice structures of varying shapes and diameters that were used for mandibular implants. Additionally, an abutment designed to carry occlusal forces was added to the top of the implants. The stress distribution of four lattice designs (tetrahedron, quad-diametral-cross, hex-star, and hex-vase) of three sizes (2.5, 3.0, and 3.5 mm) in cubic porous models were analyzed by FEA. Subsequently, two optimal designs for 3D-printed titanium alloy were selected. These designs, featuring different lattice diameters (0.5, 0.7, and 0.9 mm), were tested to determine their elastic modulus, which was used in another FEA of a mandibular implant designed for a patient with a malignant tumor in the right mandible. This model, which included an abutment design, was subjected to a vertical force of 100 N and muscle forces generated by biting. This analysis was conducted to determine the elastic modulus of the implant and the values of stress and strain on the implant and surrounding bone. The lattice designs of quad-diametral-cross and hex-vase exhibited smaller high-stress regions than those of tetrahedron and hex-star. In vitro tests revealed that the elastic modulus of the lattices increased with the rod diameter. When these values were applied to mandibular implants, Young's modulus decreased, which in turn increased the frictional stress observed at the interface between the abutment and the implant. However, the implant's maximum stress remained below its yield strength (910 MPa), and the strain on the surrounding bone varied between 1500 and 3000 mu strain. As indicated by Frost's theory, these implants are unlikely to damage the surrounding bone tissue and are likely to support bone growth.
引用
收藏
页码:567 / 581
页数:15
相关论文
共 50 条
  • [21] Biomechanical Analysis of Axial Gradient Porous Dental Implants: A Finite Element Analysis
    Zhang, Chunyu
    Wang, Yuehong
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (12)
  • [22] Biomechanical finite element analysis of small diameter and short dental implants: extensive study of commercial implants
    Bourauel, Christoph
    Aitlahrach, Maria
    Heinemann, Friedhelm
    Hasan, Istabrak
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 (01): : 21 - 32
  • [23] Biomechanical effect of implant design on four implants supporting mandibular full-arch fixed dentures: In vitro test and finite element analysis
    Wu, Aaron Yu-Jen
    Hsu, Jui-Ting
    Fuh, Lih-Jyh
    Huang, Heng-Li
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2020, 119 (10) : 1514 - 1523
  • [24] A finite element analysis study on different angle correction designs for inclined implants in All-On-Four protocol
    Christine Raouf Micheal Ibrahim
    Ahmed Sameh
    Osama Askar
    BMC Oral Health, 24
  • [25] Biomechanical effects of different mandibular movements and torque compensations during mandibular advancement with clear aligners: a finite element analysis
    Wang, Ya
    Daraqel, Baraa
    Wang, Ying
    Yang, Dan
    Dong, Yihan
    Hu, Yun
    Zheng, Leilei
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [26] Influence of Different Implants on the Biomechanical Behavior of a Tooth-Implant Fixed Partial Dentures: A Three-Dimensional Finite Element Analysis
    Lencioni, Karina Albino
    Noritomi, Pedro Yoshito
    Macedo, Ana Paula
    Ribeiro, Ricardo Faria
    de Almeida, Rossana Pereira
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (01) : 27 - 34
  • [27] Biomechanical comparison of 2 augmented glenoid designs: an integrated kinematic finite element analysis
    Sabesan, Vani J.
    Lima, Diego J. L.
    Whaley, James D.
    Pathak, Varun
    Zhang, Liying
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (06) : 1166 - 1174
  • [28] Three-dimensional finite element analysis of extra short implants focusing on implant designs and materials
    Araki, Haruka
    Nakano, Tamaki
    Ono, Shinji
    Yatani, Hirofumi
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [29] Biomechanical Comparison of Six Different Root-Analog Implants and the Conventional Morse Taper Implant by Finite Element Analysis
    Wang, Jia-Qing
    Zhang, Yuan
    Pang, Min
    Wang, Yue-Qiu
    Yuan, Jun
    Peng, Hui
    Zhang, Wen
    Dai, Lu
    Li, Hong-Wei
    FRONTIERS IN GENETICS, 2022, 13
  • [30] The Biomechanical Impact of Loss of an Implant in the Treatment with Mandibular Overdentures on Four Nonsplinted Mini Dental Implants: A Finite Element Analysis
    Teodorescu, Cristian
    Preoteasa, Elena
    Preoteasa, Cristina Teodora
    Murariu-Magureanu, Catalina
    Teodorescu, Ioana Monica
    MATERIALS, 2022, 15 (23)