Size-Specific Dose Estimate and Effective Dose for Pediatric Computed Tomography

被引:0
|
作者
Khan, Rukhsar [1 ]
Shah, Mudasir Ashraf [1 ]
Wahab, Shagufta [1 ]
Khan, Rizwan Ahmad [2 ]
机构
[1] ALIGARH MUSLIM UNIV, J N Med Coll, Fac Med, Dept Radiodiag, ALIGARH, UTTAR PRADESH, India
[2] ALIGARH MUSLIM UNIV, J N Med Coll, Fac Med, Dept Paediat Surg, ALIGARH, UTTAR PRADESH, India
关键词
Dose length product; effective dose; linear regression analysis; multivariate analysis; size-specific dose estimate; water equivalent diameter; RADIATION-EXPOSURE; CANCER INCIDENCE; SUBSEQUENT RISK; CT SCANS; TRENDS; CHILDHOOD; LEUKEMIA; ABDOMEN; TUMORS; AGE;
D O I
10.4103/jmp.jmp_55_24
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study is to present the multivariate analysis of the size-specific dose estimate (SSDE) and E in pediatric computed tomography (CT) imaging. Pediatric patients scheduled for CT scans of the head, thorax, and abdomen from July 2022 to February 2024 were included in the prospective study. The water-equivalent diameter (D-w), SSDE, and E were computed for each examination using the dose report of CT console display computed tomography dose index (CTD1(vol)) and dose length product (DLP). The correlation between SSDE and E on CTD1(vol), D-w, Area(ROI), body mass index, Size & frasl;(LAT+AP), age, f(size), and HUmean in the region of interest was examined using the multivariate statistical analysis with 95% level of significance (P < 0.05). The relationship between D-w and Size & frasl;(LAT+AP), Size & frasl;(LAT+AP), and f(size) versus age was investigated using linear regression analysis. The mean values of SSDE for noncontrast head CT and contrast-enhanced CT were found 71.36 mGy and 97.38 mGy, respectively. While as, the mean SSDE for contrast-enhanced thorax CT was observed to be 5.82 mGy, which is less than the mean SSDE of 6.40 mGy for noncontrast thorax CT imaging. The range of the SSDE for contrast-enhanced abdomen CT is 2.05 mGy to 22.13 mGy with a mean SSDE of around 5.71 mGy and for noncontrast abdomen imaging, mean value of SSDE was 5.58 mGy. The mean value of "E" for noncontrast thorax CT imaging was observed to be 2.7 mSv with minimum and maximum 1.17 mSv to 10.10 mSv respectively, which less than the mean effective dose is of 3.64 mSv observed for contrast enhanced thorax CT imaging. The multivariate analysis suggests that SSDE is significantly correlated with CTD1(vol), D-w, and E is found significantly dependent on DLP for both contrast enhanced and noncontrast imaging with p < 0.05. A strong positive correlation was found between D-w and Size & frasl;(LAT+AP), form linear regression analysis. The SSDE is crucial for radiologists evaluating pediatric CT scans and is now an international standard expected to be widely adopted. The strong positive correlation between D-w versus Size & frasl;(LAT+AP), indicates that Size & frasl;(LAT+AP),can be used as surrogate in estimate SSDE when D-w calculation is not feasible for pediatric CT imaging.
引用
收藏
页码:173 / 183
页数:11
相关论文
共 50 条
  • [31] Simplifying Size-Specific Radiation Dose Estimates in Pediatric CT
    Khawaja, Ranish Deedar Ali
    Singh, Sarabjeet
    Vettiyil, Beth
    Lim, Ruth
    Gee, Michael
    Westra, Sjirk
    Kalra, Mannudeep K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (01) : 167 - 176
  • [32] A size-specific effective dose for patients undergoing CT examinations
    Anam, C.
    Haryanto, F.
    Widita, R.
    Arif, I.
    Fujibuchi, T.
    Dougherty, G.
    7TH ASIAN PHYSICS SYMPOSIUM, 2019, 1204
  • [33] Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method
    Larson, David B.
    PEDIATRIC RADIOLOGY, 2014, 44 : 501 - 505
  • [34] Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method
    David B. Larson
    Pediatric Radiology, 2014, 44 : 501 - 505
  • [35] Estimating size specific dose estimate from computed tomography radiograph localizer with radiation risk assessment
    Burton, Christiane Sarah
    Al-Ward, Shahad
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (06):
  • [36] Determination of radiation dose during computed tomography examinations in southern Saudi Arabian hospitals using size-specific dose estimates
    Saeed, Mohammed K.
    Asiri, Abdullah Ali M.
    MAEJO INTERNATIONAL JOURNAL OF SCIENCE AND TECHNOLOGY, 2021, 15 (02) : 147 - 158
  • [37] The determination of coefficients for size specific effective dose for adult and pediatric patients undergoing routine computed tomography examinations
    Sookpeng, S.
    Martin, C. J.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (03)
  • [38] Estimation of size-specific dose estimate (SSDE) of CT scans using an effective diameter electron density
    Almuqbil, Khuloud
    Abuhaimed, Abdullah
    Abanomy, Ahmed
    Alashban, Yazeed
    Alhawas, Abdulrahman
    Martin, Colin J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 172
  • [39] EFFECTIVE DOSE VARIATION IN PEDIATRIC COMPUTED TOMOGRAPHY: DOSE REFERENCE LEVELS IN GREECE
    Yakoumakis, E.
    Karlatira, M.
    Gialousis, G.
    Dimitriadis, A.
    Makri, T.
    Georgiou, E.
    HEALTH PHYSICS, 2009, 97 (06): : 595 - 603
  • [40] Pediatric effective dose assessment for routine computed tomography examinations in Tehran, Iran
    Tahmasebzadeh, Atefeh
    Maziyar, Asghar
    Reiazi, Reza
    Kermanshahi, Mojtaba Soltani
    Anijdan, Seyyed Hossein Mousavie
    Paydar, Reza
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2022, 12 (03): : 227 - 232