Microwave Radiometer Calibration Using Low-Noise Amplifier as Calibration Source

被引:0
|
作者
Neate, Reuben [1 ]
Stander, Tinus [1 ]
机构
[1] Univ Pretoria, Carl & Emily Fuchs Inst Microelect, Dept EEC Engn, ZA-0002 Pretoria, South Africa
来源
关键词
Calibration; Noise; Temperature measurement; Microwave radiometry; Noise measurement; Switches; Microwave theory and techniques; Gain; Power measurement; Microwave technology; Atmospheric monitoring; noise calibration; remote sensing; water vapor radiometer (WVR); Y-factor;
D O I
10.1109/LMWT.2024.3474971
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a novel method for built-in noise and gain calibration of a total power radiometer using a low-noise amplifier (LNA) as the calibration source. A terminated LNA's biasing is varied to obtain multiple calibration points, with the novel postprocessing method accounting for both radiometer nonlinearity and unknown LNA parameters. This method allows for a built-in radiometer calibration without a calibrated resistive or diode noise source, instead using an internal thermometer measurement as a reference. The method is demonstrated by measuring a thermal load to a 24-GHz water vapor radiometer (WVR), achieving a mean error of 0.43 K over the band of interest under 45 degrees C ambient temperature variation. It is further shown that the calibration data can be used to estimate the radiometer's gain to within 1.41 dB and noise figure (NF) to within 0.55 dB.
引用
收藏
页码:127 / 130
页数:4
相关论文
共 50 条
  • [21] Low Noise Chopper Amplifier Calibration Module
    Wang, Si
    Xiong, Linsen
    Wu, Haonan
    Wang, Weiwei
    Niu, Yuefeng
    Chen, Kai
    PROCEEDINGS OF 2016 IEEE ADVANCED INFORMATION MANAGEMENT, COMMUNICATES, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IMCEC 2016), 2016, : 867 - 870
  • [22] Refined Self-calibration of an Inductorless Low-noise Amplifier with Non-intrusive Circuit
    Wenrun Xiao
    Jidong Diao
    Yanping Qiao
    Xianming Liu
    Shan He
    Donghui Guo
    Journal of Electronic Testing, 2023, 39 : 41 - 55
  • [23] Use of Pseudo-Random Noise Sequences in Microwave Radiometer Calibration
    Ramos-Perez, I.
    Bosch-Lluis, X.
    Camps, A.
    Marchan-Hernandez, J. F.
    Rodriguez-Alvarez, N.
    Valencia, E.
    2008 MICROWAVE RADIOMETRY AND REMOTE SENSING OF THE ENVIRONMENT, 2008, : 77 - +
  • [24] Refined Self-calibration of an Inductorless Low-noise Amplifier with Non-intrusive Circuit
    Xiao, Wenrun
    Diao, Jidong
    Qiao, Yanping
    Liu, Xianming
    He, Shan
    Guo, Donghui
    JOURNAL OF ELECTRONIC TESTING-THEORY AND APPLICATIONS, 2023, 39 (01): : 41 - 55
  • [25] THE REACTATRON - A LOW-NOISE, SEMICONDUCTOR DIODE, MICROWAVE AMPLIFIER
    BRAND, FA
    MATTHEI, WG
    SAAD, T
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1959, 47 (01): : 42 - 44
  • [26] MICROWAVE LOW-NOISE MIXING-PARAMETRICAL AMPLIFIER
    BOROVIKO.IP
    DMITRIEV, MD
    GAVRILOV, EB
    RADIOTEKHNIKA I ELEKTRONIKA, 1973, 18 (02): : 428 - 429
  • [27] LOW-NOISE FERROELECTRIC MICROWAVE PARAMETRIC-AMPLIFIER
    VENDIK, OG
    KEYS, VN
    PRUDAN, AM
    TERMARTIROSYAN, LT
    RADIOTEKHNIKA I ELEKTRONIKA, 1978, 23 (01): : 175 - 178
  • [28] SUPERCONDUCTING LOW-NOISE MICROWAVE PARAMETRIC-AMPLIFIER
    SMITH, AD
    MICROWAVES & RF, 1985, 24 (05) : 171 - 171
  • [29] SMAP MICROWAVE RADIOMETER CALIBRATION REVISIT
    Peng, Jinzheng
    Misra, Sidharth
    Piepmeier, Jeffrey
    Yueh, Simon
    Dinnat, Emmanuel
    Le Vine, David
    Meissner, Thomas
    Mohammed, Priscilla
    2019 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS 2019), 2019, : 5378 - 5380
  • [30] Frequency Dependence of Microwave Radiometer Calibration
    Goodberlet, Mark A.
    Popstefanija, Ivan
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2009, 6 (02) : 337 - 338