Dyssynchronous Fetal Heart Failure in Maternal Diabetes: Evaluation with Speckle Tracking Echocardiography and Novel M-Mode Software

被引:0
作者
Kuehle, Theresa M. [1 ]
Burgmair, Angela [2 ,3 ]
Schummers, Georg [3 ]
Moellers, Mareike [1 ]
Oelmeier, Kathrin [1 ]
De Santis, Chiara [1 ]
Koester, Helen Ann [4 ]
Moellmann, Ute [1 ]
Willy, Daniela [1 ]
Braun, Janina [1 ]
Albert, Felix [5 ]
Schmitz, Ralf [1 ]
机构
[1] Univ Hosp Munster, Clin Obstet & Gynecol, Albert Schweitzer Campus 1, D-48149 Munster, Germany
[2] Univ Appl Sci, Res Grp Med Technol, Landshut, Germany
[3] TomTec Imaging Syst GmbH, Unterschleissheim, Germany
[4] Frauenaerztin Am Mexikoplatz, Berlin, Germany
[5] Inst Biostat & Clin Res, Munster, Germany
关键词
Fetus; Gestational age; Gestational diabetes; Hyperglycemia; Echocardiography; Global longitudinal strain; Dyssynchrony; TIME 3-DIMENSIONAL ECHOCARDIOGRAPHY; STRAIN-RATE; DEFORMATION; FETUSES;
D O I
10.1016/j.ultrasmedbio.2024.10.004
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives: This study aimed to investigate dyssynchronous heart failure in fetuses of mothers with diabetes mellitus (FDM) and fetal controls (FC) using two-dimensional speckle tracking echocardiography (2D-STE) and novel M-mode prototype software (PS). Methods: In this cohort study 174 fetuses were analyzed, 87 in the FDM-cohort and 87 gestational age-matched fetuses in the FC-cohort. A subgroup of 38 fetuses formed the final case group, with a high median frame rate of approximately 160 frames/s. Using 2D Cardiac Performance Analysis software (TOMTEC, Unterschleissheim, Germany) we measured global longitudinal strain (GLS). TOMTEC PS detected annular displacement by assessing an artificial M-mode on the previously generated tracking. Dyssynchrony (DYS) was calculated as the inter- and intraventricular difference in time to peak GLS or annular displacement. Results: Greater DYS was observed in all basal myocardial measurement sites and software between FDM-cohort compared to FC-cohort and no significant correlation was found between DYS measurements and gestational age. Intraventricular DYS between the basal segments was statistically significant (all p <= 0.036, Wald test of univariate regression models). The PS performed best in DYS measurements identifying right ventricular DYS as potentially predicting FDM (FDM: median, 18.5 (interquartile range [IQR], 13.9-25.0) ms vs. FC: median, 2.7 [IQR, 1.5-3.5] ms; p < 0.001). Conclusion: Increased intraventricular DYS demonstrated an impact of maternal diabetes mellitus on fetal hearts independent of gestational age. The prototype M-mode method identified cardiac dysfunction with higher accuracy than the conventional analysis. High-quality echocardiographic image acquisition is imperative for clinical application of 2D-STE and related advanced technologies.
引用
收藏
页码:302 / 311
页数:10
相关论文
共 24 条
  • [21] Evaluation of Left Ventricular Diastolic Dysfunction with Early Systolic Dysfunction Using Two-Dimensional Speckle Tracking Echocardiography in Canine Heart Failure Model
    Wu, Wei-Chun
    Ma, Hong
    Xie, Rong-Ai
    Gao, Li-Jian
    Tang, Yue
    Wang, Hao
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2016, 33 (04): : 618 - 627
  • [22] NOVEL ESTIMATION OF LEFT VENTRICULAR FILLING PRESSURE USING 3-D SPECKLE-TRACKING ECHOCARDIOGRAPHY: ASSESSMENT IN A DECOMPENSATED SYSTOLIC HEART FAILURE MODEL
    Takeda, Serina
    Asanuma, Toshihiko
    Masuda, Kasumi
    Nakatani, Satoshi
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (06) : 1536 - 1547
  • [23] Noninvasive Evaluation of the Feature of Hypertensive Heart Failure With Preserved and Reduced Ejection Fraction using Three-dimensional Speckle Tracking Echocardiography With High Volume Rate
    Minatoguchi, Shingo
    Kawasaki, Masanori
    Tanaka, Ryuhei
    Saeki, Maki
    Nagaya, Maki
    Sato, Noriaki
    Kaneda, Mayumi
    Matsuoka, Reiko
    Miwa, Hirotaka
    Yoshizane, Takashi
    Iwama, Makoto
    Hirose, Takeshi
    Ono, Koji
    Arai, Masazumi
    Noda, Toshiyuki
    Minatoguchi, Shinya
    CIRCULATION, 2015, 132
  • [24] A Novel Approach for Predicting Atrial Fibrillation Recurrence After Ablation Using Deep Convolutional Neural Networks by Assessing Left Atrial Curved M-Mode Speckle-Tracking Images
    Hwang, Yi-Ting
    Lee, Hui-Ling
    Lu, Cheng-Hui
    Chang, Po-Cheng
    Wo, Hung-Ta
    Liu, Hao-Tien
    Wen, Ming-Shien
    Lin, Fen-Chiung
    Chou, Chung-Chuan
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 7