Dyssynchronous Fetal Heart Failure in Maternal Diabetes: Evaluation with Speckle Tracking Echocardiography and Novel M-Mode Software

被引:0
|
作者
Kuehle, Theresa M. [1 ]
Burgmair, Angela [2 ,3 ]
Schummers, Georg [3 ]
Moellers, Mareike [1 ]
Oelmeier, Kathrin [1 ]
De Santis, Chiara [1 ]
Koester, Helen Ann [4 ]
Moellmann, Ute [1 ]
Willy, Daniela [1 ]
Braun, Janina [1 ]
Albert, Felix [5 ]
Schmitz, Ralf [1 ]
机构
[1] Univ Hosp Munster, Clin Obstet & Gynecol, Albert Schweitzer Campus 1, D-48149 Munster, Germany
[2] Univ Appl Sci, Res Grp Med Technol, Landshut, Germany
[3] TomTec Imaging Syst GmbH, Unterschleissheim, Germany
[4] Frauenaerztin Am Mexikoplatz, Berlin, Germany
[5] Inst Biostat & Clin Res, Munster, Germany
关键词
Fetus; Gestational age; Gestational diabetes; Hyperglycemia; Echocardiography; Global longitudinal strain; Dyssynchrony; TIME 3-DIMENSIONAL ECHOCARDIOGRAPHY; STRAIN-RATE; DEFORMATION; FETUSES;
D O I
10.1016/j.ultrasmedbio.2024.10.004
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives: This study aimed to investigate dyssynchronous heart failure in fetuses of mothers with diabetes mellitus (FDM) and fetal controls (FC) using two-dimensional speckle tracking echocardiography (2D-STE) and novel M-mode prototype software (PS). Methods: In this cohort study 174 fetuses were analyzed, 87 in the FDM-cohort and 87 gestational age-matched fetuses in the FC-cohort. A subgroup of 38 fetuses formed the final case group, with a high median frame rate of approximately 160 frames/s. Using 2D Cardiac Performance Analysis software (TOMTEC, Unterschleissheim, Germany) we measured global longitudinal strain (GLS). TOMTEC PS detected annular displacement by assessing an artificial M-mode on the previously generated tracking. Dyssynchrony (DYS) was calculated as the inter- and intraventricular difference in time to peak GLS or annular displacement. Results: Greater DYS was observed in all basal myocardial measurement sites and software between FDM-cohort compared to FC-cohort and no significant correlation was found between DYS measurements and gestational age. Intraventricular DYS between the basal segments was statistically significant (all p <= 0.036, Wald test of univariate regression models). The PS performed best in DYS measurements identifying right ventricular DYS as potentially predicting FDM (FDM: median, 18.5 (interquartile range [IQR], 13.9-25.0) ms vs. FC: median, 2.7 [IQR, 1.5-3.5] ms; p < 0.001). Conclusion: Increased intraventricular DYS demonstrated an impact of maternal diabetes mellitus on fetal hearts independent of gestational age. The prototype M-mode method identified cardiac dysfunction with higher accuracy than the conventional analysis. High-quality echocardiographic image acquisition is imperative for clinical application of 2D-STE and related advanced technologies.
引用
收藏
页码:302 / 311
页数:10
相关论文
共 24 条
  • [11] Evaluation of prenatal changes in fetal cardiac morphology and function in maternal diabetes mellitus using a novel fetal speckle-tracking analysis: a prospective cohort study
    Wang, Dong
    Liu, Caixia
    Liu, Xinyu
    Zhang, Ying
    Wang, Yu
    CARDIOVASCULAR ULTRASOUND, 2021, 19 (01)
  • [12] Evaluation of fetal cardiac functions in the setting of maternal diabetes: Application of the global spherical index, global strain and fractional area change by the speckle tracking technique
    Song, Yan
    Yin, Hong
    Wang, Wen
    Zou, Yu-fen
    Liu, De-quan
    Zhang, Ge
    Ji, Xiao-ping
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2021, 264 : 162 - 167
  • [13] Evaluation of prenatal changes in fetal cardiac morphology and function in maternal diabetes mellitus using a novel fetal speckle-tracking analysis: a prospective cohort study
    Dong Wang
    Caixia Liu
    Xinyu Liu
    Ying Zhang
    Yu Wang
    Cardiovascular Ultrasound, 19
  • [14] Fetal tricuspid annular plane systolic excursion (f-TAPSE): evaluation of fetal right heart systolic function with conventional M-mode ultrasound and spatiotemporal image correlation (STIC) M-mode
    Messing, B.
    Gilboa, Y.
    Lipschuetz, M.
    Valsky, D. V.
    Cohen, S. M.
    Yagel, S.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2013, 42 (02) : 182 - 188
  • [15] The evaluation of fetal interventricular septum with M-mode and spectral tissue Doppler imaging in gestational diabetes mellitus: a case-control study
    Oluklu, Deniz
    Beser, Dilek Menekse
    Hendem, Derya Uyan
    Yildirim, Muradiye
    Ersak, Duygu Tugrul
    Turgut, Ezgi
    Sahin, Dilek
    JOURNAL OF PERINATAL MEDICINE, 2024, 52 (02) : 239 - 245
  • [16] Quality Control and Reproducibility in M-Mode, Two-Dimensional, and Speckle Tracking Echocardiography Acquisition and Analysis: The CARDIA Study, Year 25 Examination Experience
    Armstrong, Anderson C.
    Ricketts, Erin P.
    Cox, Christopher
    Adler, Paul
    Arynchyn, Alexander
    Liu, Kiang
    Stengel, Ellen
    Sidney, Stephen
    Lewis, Cora E.
    Schreiner, Pamela J.
    Shikany, James M.
    Keck, Kimberly
    Merlo, Jamie
    Gidding, Samuel S.
    Lima, Joao A. C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (08): : 1233 - 1240
  • [17] Evaluation of systolic and diastolic properties of hypertensive heart failure using speckle-tracking echocardiography with high volume rates
    Minatoguchi, Shingo
    Kawasaki, Masanori
    Tanaka, Ryuhei
    Yoshizane, Takashi
    Ono, Koji
    Saeki, Maki
    Nagaya, Maki
    Sato, Hidemaro
    Nishigaki, Kazuhiko
    Noda, Toshiyuki
    Zile, Michael R.
    Minatoguchi, Shinya
    HEART AND VESSELS, 2017, 32 (10) : 1202 - 1213
  • [18] Evaluation of right ventricular myocardial deformation properties in fetal hypoplastic left heart by two-dimensional speckle tracking echocardiography
    Enzensberger, Christian
    Graupner, Oliver
    Fischer, Stefanie
    Meister, Markus
    Reitz, Maleen
    Goette, Malena
    Mueller, Vera
    Wolter, Aline
    Herrmann, Johannes
    Axt-Fliedner, Roland
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2023, 307 (03) : 699 - 708
  • [19] Left ventricular function evaluation of the fetal heart: reference intervals and inter-observer variability of 2D speckle-tracking echocardiography measurements
    Gozar, Liliana
    Sasaran, Maria Oana
    Toma, Daniela
    Cerghit-Paler, Andreea
    Molnar-Varlam, Claudiu
    Marginean, Claudiu
    Sasaran, Vladut
    MEDICAL ULTRASONOGRAPHY, 2023, 25 (02) : 168 - 174
  • [20] Quantitative Analysis of Stress Echocardiograms in Healthy Horses with 2-Dimensional (2D) Echocardiography, Anatomical M-Mode, Tissue Doppler Imaging, and 2D Speckle Tracking
    Schefer, K. D.
    Bitschnau, C.
    Weishaupt, M. A.
    Schwarzwald, C. C.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2010, 24 (04) : 918 - 931