Reliability of Hand-Held Dynamometer Measurement for Thumb Palmar Abduction Strength in Carpal Tunnel Syndrome

被引:0
|
作者
Doi, Kazuteru [1 ]
Yasui, Noritada [1 ]
Isomura, Yuya [1 ]
Tagawa, Masafumi [1 ]
Hattori, Yasunori [1 ]
Sakamoto, Sotetsu [1 ]
机构
[1] Ogori Daiichi Gen Hosp, Ogori, Yamaguchi, Japan
关键词
Carpal tunnel syndrome; Hand-held dynamometer; Thumb palmar abduction; Bland-Altman analysis; Minimal detectable changes; INTERRATER RELIABILITY; MUSCLE; INDIVIDUALS; INTRARATER;
D O I
10.1142/S2424835525500262
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: In carpal tunnel syndrome (CTS), pain and sensory disturbance are the main symptoms, but thumb palmar abduction (TPA) paralysis cannot be ignored as a concurrent symptom. The reliable quantitative measurement of TPA power was not established. The purpose of this study was to report on the reliability of TPA strength measurements by the hand-held dynamometry (HHD) in large samples of CTS and its superiority over other tests, including grip, pinch powers, TPA angles and manual muscle testing, in terms of clinical progress indicators. Methods: We examined the relative and absolute reliabilities of the perioperative TPA strength measured by HHD (HHD-TPA) in 566 participants with CTS and the correlation coefficient between the HHD-TPA and other clinical tests. Results: The reliability of the HHD-TPA was intraclass correlation coefficients: 97% or higher. The Bland-Altman absolute reliability showed a random pattern of bias, and the minimal detectable changes (MDC) of the inter-rater and intra-rater reliabilities indicated 9.0 N and 7.0 N individually. The HHD-TPA showed statistically significant recoveries between perioperative stages; however, the mean difference larger than the MDC was recognised only between the preoperative and 12-month postoperative stages by intra-rater comparison. More individual patients showed recovery of HHD-TPA beyond the MDC when the same examiner continuously measured HHD-TPA than when multiple examiners continuously measured HHD-TPA. Grip strength and pinch strength measurements showed a strong correlation with HHD-TPA and did not show statistically significant improvement during the perioperative period. Conclusions: HHD-TPA is the most reliable method for quantifying muscle strength in the perioperative course of TPA force in CTS. HHD-TPA is a more reliable assessment of CTS motor recovery when measured consistently for each patient by the same hand therapist.
引用
收藏
页码:155 / 165
页数:11
相关论文
共 50 条
  • [1] Intrarater and interrater reliability of a hand-held dynamometric technique to quantify palmar thumb abduction strength in individuals with and without carpal tunnel syndrome
    Mathews, Harvey
    Middleton, Addie
    Boan, Lindsey
    Jacks, Madison
    Riddick, Lindsey
    Shepherd, Jessica
    Patel, Jay
    McNeal, Antonia
    Fritz, Stacy
    JOURNAL OF HAND THERAPY, 2018, 31 (04) : 554 - 561
  • [2] Thumb abduction strength measurement in carpal tunnel syndrome
    Agabegi, Steven S.
    Freiberg, Richard A.
    Plunkett, James A.
    Stern, Peter J.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (06): : 859 - 866
  • [3] Reliability of measurements of hip abduction strength obtained with a hand-held dynamometer
    Ieiri, Akira
    Tushima, Eiki
    Ishida, Kazuhiro
    Inoue, Masahiro
    Kanno, Taiki
    Masuda, Takeshi
    PHYSIOTHERAPY THEORY AND PRACTICE, 2015, 31 (02) : 146 - 152
  • [4] Reliability of a new stabilization device for measurement of muscle strength using a hand-held dynamometer
    Yasaci, Zeynal
    Argut, Sezen Karaborklu
    Celik, Derya
    MUSCLE & NERVE, 2024, 70 (06) : 1240 - 1246
  • [5] Reliability and validity of eccentric strength measurement of the shoulder abductor muscles using a hand-held dynamometer
    Karabay, Damla
    Yesilyaprak, Sevgi Sevi
    Picak, Gonca Sahiner
    PHYSICAL THERAPY IN SPORT, 2020, 43 : 52 - 57
  • [6] Development and reliability of a hand-held dynamometer device to measure the ankle dorsiflexor muscle strength
    Kimura, Masanobu
    Ogata, Yuto
    Akebi, Toru
    Ochi, Mitsuhiro
    Hachisuka, Kenji
    Saeki, Satoru
    JOURNAL OF REHABILITATION AND ASSISTIVE TECHNOLOGIES ENGINEERING, 2018, 5
  • [7] Reliability of muscle strength measures obtained with a hand-held dynamometer in an elderly population
    Buckinx, Fanny
    Croisier, Jean-Louis
    Reginster, Jean-Yves
    Dardenne, Nadia
    Beaudart, Charlotte
    Slomian, Justine
    Leonard, Sylvain
    Bruyere, Olivier
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2017, 37 (03) : 332 - 340
  • [8] Reliability of a new hand-held dynamometer in measuring shoulder range of motion and strength
    Cadogan, Angela
    Laslett, Mark
    Hing, Wayne
    McNair, Peter
    Williams, Maynard
    MANUAL THERAPY, 2011, 16 (01) : 97 - 101
  • [9] Reliability and Validity of Hand-Held Dynamometer and Hand-Held Sphygmomanometer for Testing Shoulder Isometric External and Internal Rotator Muscles Strength
    Bettariga, Francesco
    Lopomo, Nicola Francesco
    Civera, Fabio
    Lazzarini, Stefano Giuseppe
    Mantovani, Lisa
    Maestroni, Luca
    JOURNAL OF SCIENCE IN SPORT AND EXERCISE, 2024, 6 (04) : 386 - 393
  • [10] Hand-held nerve conduction device in carpal tunnel syndrome: A prospective study
    Tan, S. Veronica
    Sandford, Fiona
    Stevenson, Mark
    Probert, Sara
    Sanders, Sue
    Mills, Kerry R.
    Koutroumanidis, Michaelis
    MUSCLE & NERVE, 2012, 45 (05) : 635 - 641