Repeatability and agreement of a new anterior segment optical coherence tomography with standard devices in normal, keratoconus, and post-refractive eyes

被引:0
|
作者
Kundu, Gairik [1 ]
Shetty, Naren [2 ]
Modak, Durgalaxmi [1 ]
Kaweri, Luci [3 ]
Khamar, Pooja [2 ]
Arora, Vishal [4 ]
Nuijts, Rudy M. M. A. [5 ]
Shetty, Rohit [1 ]
机构
[1] Narayana Nethralaya, Dept Cornea & Refract Surg, Bengaluru, Karnataka, India
[2] Narayana Nethralaya, Dept Cataract & Refract Surg, Bengaluru, Karnataka, India
[3] ASG Eye Hosp, Dept Cataract & Refract Surg, Mysore, Karnataka, India
[4] Aro Hlth, Dept Cataract & Refract Surg, Gurugram, Haryana, India
[5] Maastricht Univ Med Ctr, Dept Ophthalmol, Maastricht, Netherlands
关键词
Agreement; Anterion; Eyestar; 900; MS-39; Pentacam AXL Wave; repeatability; IMAGING-SYSTEMS; OCT; REPRODUCIBILITY; HEALTHY; ABERROMETER; PARAMETERS; BIOMETERS;
D O I
10.4103/IJO.IJO_805_24
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To assess repeatability and agreement of Eyestar 900 (Haag-Streit, K & ouml;niz, Switzerland) with Pentacam AXL Wave system (Oculus, Wetzlar, Germany), Anterion (Heidelberg Engineering GmBH, Heidelberg, Germany), and MS-39 (CSO, Florence, Italy) in measuring anterior segment parameters. Methods:Two hundred normal eyes, 50 keratoconus (KC) eyes, and 50 post-refractive surgery eyes underwent three sequential scans on each instrument. The order of scans was randomized. Repeatability was assessed using within-subject standard deviation (Sw) and intraclass correlation coefficient (ICC). Bland-Altman analysis was used to assess the 95% limits of agreement. Results:Eyestar 900 had comparable repeatability to Anterion and MS-39 across groups. ICC was overall >0.8. Pentacam AXL Wave had lower Sw (better repeatability) across all groups. In normal eyes, Eyestar 900 can be used interchangeably with MS-39 and Anterion (P > 0.23). Eyestar 900 and Pentacam AXL Wave did not show agreement on any parameter, except anterior chamber depth (ACD) (P = 0.92). Eyestar 900 in KC eyes can be used interchangeably with MS-39, except for posterior keratometry (pK) and thinnest corneal thickness (TCT) (P < 0.001), and with Anterion, except for TCT and ACD (P < 0.001). In post-refractive eyes, Eyestar 900 can be used interchangeably with MS-39, except for pK (P < 0.001), and with Anterion, except for ACD (P < 0.001). Pentacam AXL Wave and Eyestar 900 cannot be used interchangeably in KC and post-refractive eyes. Conclusions:Newer devices such as Eyestar 900 can be used interchangeably with Anterion and MS-39 in normal eyes and partly in KC and post-refractive eyes. Pentacam AXL Wave and Eyestar 900 cannot be used interchangeably across the various groups. However, these multifunctional hybrid tools of combined topography, AS-OCT, can be helpful in refractive clinics.
引用
收藏
页码:325 / 334
页数:12
相关论文
共 50 条
  • [1] Repeatability of automated measurements by a new anterior segment optical coherence tomographer and biometer and agreement with standard devices
    Schiano-Lomoriello, Domenico
    Hoffer, Kenneth J.
    Abicca, Irene
    Savini, Giacomo
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] Repeatability and agreement of biometric measurements using spectral domain anterior segment optical coherence tomography and Scheimpflug tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mohammed
    PLOS ONE, 2021, 16 (05):
  • [3] Repeatability of anterior segment measurements by optical coherence tomography combined with Placido disk corneal topography in eyes with keratoconus
    Schiano-Lomoriello, Domenico
    Bono, Valeria
    Abicca, Irene
    Savini, Giacomo
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [4] Ectasia Detection by Anterior Segment Optical Coherence Tomography in Scheimpflug Tomographically Normal Keratoconus Fellow Eyes
    Naujokaitis, Tadas
    Augustin, Victor A.
    Son, Hyeck-Soo
    Koeppe, Maximilian
    Kovalchuk, Bogdana
    Auffarth, Gerd U.
    Khoramnia, Ramin
    CORNEA, 2024, 43 (07) : 812 - 819
  • [5] Agreement in anterior segment measurements between swept-source optical coherence and dual Scheimpflug tomography devices in keratoconus eyes
    Lee, Yunjin
    Oh, Joo Youn
    Choi, Hyuk Jin
    Kim, Mee Kum
    Yoon, Chang Ho
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [6] Anterior segment characteristics in normal and keratoconus eyes evaluated with a new type of swept-source optical coherence tomography
    Kim, Kook Young
    Lee, Seongjun
    Jeon, Young Joon
    Min, Ji Sang
    PLOS ONE, 2022, 17 (09):
  • [7] Inter-rater Reliability and Repeatability of Manual Anterior Segment Optical Coherence Tomography Image Grading in Keratoconus
    Lin, Anna N.
    Mohammed, Isa S. K.
    Munir, Wuqaas M.
    Munir, Saleha Z.
    Alexander, Janet L.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2021, 47 (09): : 494 - 499
  • [8] Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes
    Ghoreishi, Seyed Mohammad
    Mortazavi, Seyed Ali Akbar
    Abtahi, Zahra-Alsadat
    Abtahi, Mohammad-Ali
    Sonbolestan, Seyed Ali
    Abtahi, Seyed-Hossein
    Mohammadinia, Mohadeseh
    Isfahani, Kimia Nekouie
    INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (04) : 965 - 971
  • [9] Repeatability and agreement of a Scheimpflug-Placido tomography and a Partial Coherence Interferometer in keratoconus and control eyes
    Ozkan, Yaprak
    Gokcinar, Nesrin Buyuktortop
    INTERNATIONAL OPHTHALMOLOGY, 2025, 45 (01)
  • [10] Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mohammed
    PLOS ONE, 2021, 16 (06):