Optimal Spectral Performance on Pediatric Photon-Counting CT: Investigating Phantom-Based Size-Dependent kV Selection for Spectral Body Imaging

被引:0
作者
Zhou, Wei [1 ]
Ataei, Afrouz [2 ]
Huo, Donglai [1 ]
Ren, Liqiang [2 ]
Browne, Lorna P. [1 ,3 ]
Zhou, Xin [4 ,5 ]
Weinman, Jason P. [1 ,3 ]
机构
[1] Univ Colorado, Dept Radiol, Anschutz Med Campus,13123 E 16th Ave, Aurora, CO 80045 USA
[2] Univ Texas Southwestern Med Ctr, Dept Radiol, Dallas, TX USA
[3] Childrens Hosp Colorado, Dept Radiol, Aurora, CO USA
[4] Univ Minnesota, Dept Bioinformat & Computat Biol, St Paul, MN USA
[5] Univ Colorado, Dept Pathol, Anschutz Med Campus, Aurora, CO USA
关键词
photon-counting CT; kV selection; spectral performance; virtual monoenergetic images; iodine map; RADIATION-DOSE REDUCTION; LOW-TUBE-VOLTAGE; DETECTOR CT; PATIENT SIZE; PRINCIPLES; IMPACT; NOISE;
D O I
10.1097/RLI.0000000000001119
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The comprehensive evaluation of kV selection on photon-counting computed tomography (PCCT) has yet to be performed. The aim of the study is to evaluate and determine the optimal kV options for variable pediatric body sizes on the PCCT unit. Materials and Methods In this study, 4 phantoms of variable sizes were utilized to represent abdomens of newborn, 5-year-old, 10-year-old, and adult-sized pediatric patients. One solid water and 4 solid iodine inserts with known concentrations (2, 5, 10, and 15 mg I/mL) were inserted into phantoms. Each phantom setting was scanned on a PCCT system (Siemens Alpha) with 4 kV options (70 and 90 kV under Quantum Mode, 120 and 140 kV under QuantumPlus Mode) and clinical dual-source (3.0 pitch) protocol. For each phantom setting, radiation dose (CTDIvol) was determined by clinical dose settings and matched for all kV acquisitions. Sixty percent clinical dose images were also acquired. Reconstruction was matched across all acquisitions using Qr40 kernel and QIR level 3. Virtual monoenergetic images (VMIs) between 40 and 80 keV with 10 keV interval were generated on the scanner. Low-energy and high-energy images were reconstructed from each scan and subsequently used to generate an iodine map (IM) using an image-based 2-material decomposition method. Image noise of VMIs from each kV acquisition was calculated and compared between kV options. Absolute percent error (APE) of iodine CT number accuracy in VMIs was calculated and compared. Root mean square error (RMSE) and bias of iodine quantification from IMs were compared across kV options. Results At the newborn size and 50 keV VMI, noise is lower at low kV acquisitions (70 kV: 10.5 HU, 90 kV: 10.4 HU), compared with high kV acquisitions (120 kV: 13.8 HU, 140 kV: 13.9 HU). At the newborn size and 70 keV VMI, the image noise from different kV options is comparable (9.4 HU for 70 kV, 8.9 HU for 90 kV, 9.7 HU for 120 kV, 10.2 HU for 140 kV). For APE of VMI, high kV (120 or 140 kV) performed overall better than low kV (70 or 90 kV). At the 5-year-old size, APE of 90 kV (median: 3.6%) is significantly higher (P < 0.001, Kruskal-Wallis rank sum test with Bonferroni correction) than 140 kV (median: 1.6%). At adult size, APE of 70 kV (median: 18.0%) is significantly higher (P < 0.0001, Kruskal-Wallis rank sum test with Bonferroni correction) than 120 kV (median: 1.4%) or 140 kV (median: 0.8%). The high kV also demonstrated lower RMSE and bias than the low kV across all controlled conditions. At 10-year-old size, RMSE and bias of 120 kV are 1.4 and 0.2 mg I/mL, whereas those from 70 kV are 1.9 and 0.8 mg I/mL. Conclusions The high kV options (120 or 140 kV) on the PCCT unit demonstrated overall better performance than the low kV options (70 or 90 kV), in terms of image quality of VMIs and IMs. Our results recommend the use of high kV for general body imaging on the PCCT.
引用
收藏
页码:245 / 252
页数:8
相关论文
共 48 条
  • [1] Procedure for optimal implementation of automatic tube potential selection in pediatric CT to reduce radiation dose and improve workflow
    Browne, Jacinta E.
    Bruesewitz, Michael R.
    Thomas, Vrieze
    Thomas, Kristen B.
    Hull, Nathan C.
    McCollough, Cynthia H.
    Yu, Lifeng
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (02): : 194 - 202
  • [2] Optimization of beam quality for photon-counting spectral computed tomography in head imaging: simulation study
    Chen, Han
    Xu, Cheng
    Persson, Mats
    Danielsson, Mats
    [J]. JOURNAL OF MEDICAL IMAGING, 2015, 2 (04)
  • [3] Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications
    D'Angelo, Tommaso
    Cicero, Giuseppe
    Mazziotti, Silvio
    Ascent, Giorgio
    Albrecht, Moritz H.
    Martin, Simon S.
    Othman, Ahmed E.
    Vogl, Thomas J.
    Wichmann, Julian L.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1098)
  • [4] Clinical Applications of Photon-counting CT: A Review of Pioneer Studies and a Glimpse into the Future
    Douek, Philippe C.
    Boccalini, Sara
    Oei, Edwin H. G.
    Cormode, David P.
    Pourmorteza, Amir
    Boussel, Loic
    Si-Mohamed, Salim A.
    Budde, Ricardo P. J.
    [J]. RADIOLOGY, 2023, 309 (01)
  • [5] Optimal Virtual Monoenergetic Photon Energy (keV) for Photon-Counting-Detector Computed Tomography Angiography
    Dunning, Chelsea A. S.
    Rajendran, Kishore
    Inoue, Akitoshi
    Rajiah, Prabhakar
    Weber, Nikkole
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Leng, Shuai
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (04) : 569 - 575
  • [6] Photon-counting CT in Thoracic Imaging: Early Clinical Evidence and Incorporation Into Clinical Practice
    Fletcher, Joel G.
    Inoue, Akitoshi
    Bratt, Alex
    Horst, Kelly K.
    Koo, Chi Wan
    Rajiah, Prabhakar Shantha
    Baffour, Francis I.
    Ko, Jane P.
    Remy-Jardin, Martine
    Mccollough, Cynthia H.
    Yu, Lifeng
    [J]. RADIOLOGY, 2024, 310 (03)
  • [7] Technical Basics and Clinical Benefits of Photon-Counting CT
    Flohr, Thomas
    Schmidt, Bernhard
    [J]. INVESTIGATIVE RADIOLOGY, 2023, 58 (07) : 441 - 450
  • [8] Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast Media
    Grant, Katharine L.
    Flohr, Thomas G.
    Krauss, Bernhard
    Sedlmair, Martin
    Thomas, Christoph
    Schmidt, Bernhard
    [J]. INVESTIGATIVE RADIOLOGY, 2014, 49 (09) : 586 - 592
  • [9] Appropriate Patient Selection at Abdominal Dual-Energy CT Using 80 kV: Relationship between Patient Size, Image Noise, and Image Quality
    Guimaraes, Luis S.
    Fletcher, Joel G.
    Harmsen, William S.
    Yu, Lifeng
    Siddiki, Hassan
    Melton, Zachary
    Huprich, James E.
    Hough, David
    Hartman, Robert
    McCollough, Cynthia H.
    [J]. RADIOLOGY, 2010, 257 (03) : 732 - 742
  • [10] Photon-Counting Detector CT for Femoral Stent Imaging in an Extracorporeally Perfused Human Cadaveric Model
    Hartung, Viktor
    Gruschwitz, Philipp
    Huflage, Henner
    Augustin, Anne Marie
    Kleefeldt, Florian
    Peter, Dominik
    Lichthardt, Sven
    Erguen, Sueleyman
    Bley, Thorsten Alexander
    Grunz, Jan-Peter
    Petritsch, Bernhard
    [J]. INVESTIGATIVE RADIOLOGY, 2024, 59 (04) : 320 - 327