Utilizing Colorimetric Gas Sensors as a Selective Detector for Gas Chromatography

被引:0
作者
Chen, Jiashang [1 ]
Huang, Jin [1 ]
Fang, Hui [1 ]
Qu, Hemi [1 ]
机构
[1] Nanning Normal Univ, Coll Chem & Mat Sci, Guangxi Key Lab Nat Polymer Chem & Phys, Nanning 530001, Peoples R China
关键词
MICRO; ARRAY; GC; COLUMN; AIR; RECOGNITION; FILM;
D O I
10.1021/acs.analchem.4c06940
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Colorimetric gas sensors show promise as selective detectors for gas chromatography (GC), but their application has been limited by the irreversibility of their responses. This study presents the successful hyphenation of colorimetric gas sensors with GC, overcoming this limitation through a novel approach that refreshes the sensor's reaction area with controlled movement, enabling the generation of reversible GC peaks. The sensors, based on acid-base indicators, such as chlorophenol red and bromocresol green, were integrated with a capillary GC column and evaluated for amine detection. Performance testing revealed satisfactory sensitivity, linearity, and reproducibility, with the colorimetric sensors demonstrating superior selectivity for amines compared to flame ionization detectors (FID). Moreover, a dual-sensor array, combined with a pattern recognition algorithm, enabled effective discrimination between various amine compounds. This work establishes a promising, cost-effective alternative for portable GC systems, enhancing selectivity and improving the capability of field vapor analysis.
引用
收藏
页码:5251 / 5258
页数:8
相关论文
共 50 条
  • [41] Progressive Cellular Architecture in Microscale Gas Chromatography for Broad Chemical Analyses
    Liao, Weilin
    Zhao, Xiangyu
    Lu, Hsueh-Tsung
    Byambadorj, Tsenguun
    Qin, Yutao
    Gianchandani, Yogesh B.
    SENSORS, 2021, 21 (09)
  • [42] Design and construct of a new detector for gas chromatography based on continuous negative corona discharge
    Ghahfarokhi, M. Sharifian
    Khayamian, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (05)
  • [43] Phosphine estimation in fumigated food grains using gas chromatography equipped with FPD detector
    Arora, Sumitra
    Patil, Naveenkumar
    Adak, Totan
    Stanley, J.
    Jena, Mayabini
    Patel, Falguni
    Patel, Montu
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2023, 195 (09)
  • [44] Rapid, sensitive, and multiplexed on-chip optical sensors for micro-gas chromatography
    Reddy, Karthik
    Guo, Yunbo
    Liu, Jing
    Lee, Wonsuk
    Oo, Maung Kyaw Khaing
    Fan, Xudong
    LAB ON A CHIP, 2012, 12 (05) : 901 - 905
  • [45] Microfabricated Formaldehyde Gas Sensors
    Flueckiger, Jonas
    Ko, Frank K.
    Cheung, Karen C.
    SENSORS, 2009, 9 (11) : 9196 - 9215
  • [46] Sensors in air and gas monitoring
    Nowakowski, A
    OPTICAL TECHNIQUES FOR ENVIRONMENTAL SENSING, WORKPLACE SAFETY, AND HEALTH MONITORING, 2002, 4887 : 50 - 54
  • [47] Comparison of Supercritical Fluid Chromatography Hyphenated to an Ultraviolet Detector and Gas Chromatography Hyphenated to a Flame Ionization Detector for Qualitative and Quantitative Analysis of Citrus Essential Oils
    Santerre, Cyrille
    Delannay, Eldra
    Franco, Pilar
    Vallet, Nadine
    Touboul, David
    SEPARATIONS, 2022, 9 (07)
  • [48] Formaldehyde Gas Sensors: A Review
    Chung, Po-Ren
    Tzeng, Chun-Ta
    Ke, Ming-Tsun
    Lee, Chia-Yen
    SENSORS, 2013, 13 (04): : 4468 - 4484
  • [49] Pulsed discharge helium ionization detector with multiple combined bias/collecting electrodes for gas chromatography
    Cai, Huamin
    Stearns, Stanley D.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1284 : 163 - 173
  • [50] Application of Gas Chromatography with a Pulsed Discharge Helium Ionization Detector for Measurements of Molecular Hydrogen in the Atmosphere
    Novelli, P. C.
    Crotwell, A. M.
    Hall, B. D.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (07) : 2431 - 2436