Study on the influence of three-phase voltage unbalance on electromagnetic performance and vibration of high-voltage line-start permanent magnet synchronous motor

被引:0
作者
Yang, Cunxiang [1 ]
Jia, Jichao [1 ]
Liang, Jianing [1 ]
Wang, Zhenjiang [1 ]
Qiu, Hongbo [2 ]
机构
[1] Zhengzhou Univ Light Ind, Coll Bldg Environm Engn, Zhengzhou City, Henan, Peoples R China
[2] Zhengzhou Univ Light Ind, Coll Elect & Informat Engn, Zhengzhou City, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
modal; radial electromagnetic force; torque harmonics; torque ripple; vibration; harmonic response; INDUCTION-MOTOR; DEMAGNETIZATION;
D O I
10.24425/aee.2025.153020
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Since the operation of the high-voltage line-start permanent magnet synchronous motor (HVLSPMSM) does not need the control circuit and is directly powered by the grid, its operating stability is easily affected by the three-phase voltage unbalance. Thus, a 10 kV, 630 kW motor is taken as an example to study the impact of voltage unbalance on its electromagnetic performance and vibration. First, the effect of voltage unbalance on the torque performance of the motor is investigated using the finite element method (FEM), and the variation rules of torque ripple and torque harmonic frequency with voltage unbalance degree are obtained. Then, the analytical expressions of radial electromagnetic force (REF) under normal and unbalanced voltage conditions are derived, and the rules of electromagnetic force variation of different orders and frequencies under rated load and unbalanced voltage conditions are determined, and the analytical results are verified by finite element results. Finally, the motor vibration response characteristics caused by three-phase voltage unbalance are obtained by using modal analysis and vibration harmonic response analysis. The results indicate that the vibration performance of the motor is significantly affected by the threeamplitude of 800 Hz and 900 Hz increases by 18.03% and 78.57%, respectively.
引用
收藏
页码:209 / 226
页数:18
相关论文
共 17 条
[1]  
Chai Feng, 2023, Proceedings of the Chinese Society for Electrical Engineering, P5203, DOI 10.13334/j.0258-8013.pcsee.220432
[2]   A Quantitative Comparative Analysis of a Novel Flux-Modulated Permanent-Magnet Motor for Low-Speed Drive [J].
Fu, W. N. ;
Ho, S. L. .
IEEE TRANSACTIONS ON MAGNETICS, 2010, 46 (01) :127-134
[3]   Correlation Model Between Voltage Unbalance and Mechanical Overload Based on Thermal Effect at the Induction Motor Stator [J].
Gonzalez-Cordoba, Jose L. ;
Osornio-Rios, Roque A. ;
Granados-Lieberman, David ;
Romero-Troncoso, Rene De J. ;
Valtierra-Rodriguez, Martin .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2017, 32 (04) :1602-1610
[4]   Analysis of irreversible magnet demagnetization in line- start motors based on the finite-element method [J].
Kang, GH ;
Hur, J ;
Nam, H ;
Hong, JP ;
Kim, GT .
IEEE TRANSACTIONS ON MAGNETICS, 2003, 39 (03) :1488-1491
[5]   Causes and effects of unbalanced voltages serving an induction motor [J].
Kersting, WH .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2001, 37 (01) :165-170
[6]   Effects of various unbalanced voltages on the operation performance of an induction motor under the same voltage unbalance factor condition [J].
Lee, CY ;
Chen, BK ;
Lee, WJ ;
Hsu, YF .
1997 IEEE INDUSTRIAL & COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE - CONFERENCE RECORD, 1997, :51-59
[7]   Comparative analysis of energy performance of squirrel cage induction motor, line-start synchronous reluctance and permanent magnet motors employing the same stator design [J].
Lyskawinski, Wieslaw .
ARCHIVES OF ELECTRICAL ENGINEERING, 2020, 69 (04) :967-981
[8]   Investigation and Countermeasures for Demagnetization in Line Start Permanent Magnet Synchronous Motors [J].
Shen, Jian-Xin ;
Li, Peng ;
Jin, Meng-Jia ;
Yang, Guang .
IEEE TRANSACTIONS ON MAGNETICS, 2013, 49 (07) :4068-4071
[9]   Classical Direct Torque Control performance of Line Start PM Synchronous Motor for different conditions [J].
Soreshjani, Mohsen Hosseinzadeh ;
Haghparast, Mortaza .
INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2015, 25 (11) :2595-2620
[10]  
[唐旭 Tang Xu], 2015, [中国电机工程学报, Proceedings of the Chinese Society of Electrical Engineering], V35, P6172