Rebound tonometry intraocular pressure reference values for conscious adult Egyptian vultures (Neophron percnopterus)

被引:0
作者
Prieto, Lucia Gomez [1 ,2 ]
Byron-Chance, Dominic [1 ,2 ]
Hollwarth, Ashton J. [1 ,2 ]
Dutton, Thomas A. G.
机构
[1] Great Western Exot, Swindon, England
[2] Chocolate Factory, IVC Evidensia, Bristol, England
关键词
intraocular pressure; reference values; Egyptian vulture; Neophron percnopterus; rebound tonometry; OPHTHALMIC EXAMINATION; OCULAR PARAMETERS; TONOVET(R); LESIONS;
D O I
10.2460/ajvr.24.10.0308
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To obtain standard reference values of intraocular pressure measured with rebound tonometry in conscious healthy Egyptian vultures (Neophron percnopterus). Methods 17 Egyptian vultures presented for a routine health check, involving a full physical examination, blood film examina-tion, Hct, manual total leukocyte count, and plasma biochemistry. 15 animals considered healthy and with no signs of stress underwent an ophthalmic examination, including observation of facial symmetry, adnexa, and direct fundoscopy to screen for ocular disease. Healthy animals, with no evidence of ocular disease and no signs of stress, were included in the study. The birds were manually restraint in an upright position for rebound tonometry of the right and left eyes. Results Mean and SD of intraocular pressure were 27.33 +/- 3.54 mm Hg for the right eye and 27.00 +/- 4.11 mm Hg for the left eye. There was no statistical difference when comparing the right and left eyes. The combined mean +/- SD for both eyes was 27.2 +/- 3.76 mm Hg. Conclusions Rebound tonometry was well tolerated in all animals included in the study. The results of intraocular pressure with rebound tonometry can be used as reference values during the ophthalmological examination of Egyptian vultures. Clinical Relevance The investigation of vision threatening diseases in Egyptian vultures may necessitate rebound tonometry as part of a comprehensive ophthalmologic examination. Rebound tonometry values obtained from anesthetized Egyptian vultures, or Egyptian vultures restrained in lateral, dorsal, or sternal positions, may differ from those reported here.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Determination of reference values for tear production and intraocular pressure in Pygoscelis penguins of the Antarctic Peninsula
    Latife Cakir Bayram
    Cafer Tayer Isler
    Görkem Ekebas
    BMC Veterinary Research, 19
  • [42] Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients
    Vincent, Stephen J.
    Vincent, Roslyn A.
    Shields, David
    Lee, Graham A.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (04) : E163 - E170
  • [43] Dynamic Contour Tonometry and Goldmann Applanation Tonometry: Difference of Intraocular Pressure Values Between Eyes with and without Glaucomatous Damage in Thin Corneas
    Akkan, J. C. Umurhan
    Akkan, F.
    Akcay, B. I. Sezgin
    Ayintap, E.
    Tuncer, K.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (10) : 1190 - 1197
  • [44] Determination of Intraocular Pressure in Clinically Healthy Turkish Eastern Anatolian Red Cattle of Different Age Groups Using Rebound Tonometry
    Yakan, S.
    Isler, C. T.
    Denk, H.
    ISRAEL JOURNAL OF VETERINARY MEDICINE, 2021, 76 (04): : 150 - 155
  • [45] MEASURING INTRAOCULAR PRESSURE IN WHITE'S TREE FROGS (LITORIA CAERULEA) BY REBOUND TONOMETRY: COMPARING DEVICE, TIME OF DAY, AND MANUAL VERSUS CHEMICAL RESTRAINT METHODS
    Hausmann, Jennifer C.
    Krisp, Ashley
    Sladky, Kurt
    Miller, Paul E.
    Mans, Christoph
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2017, 48 (02) : 413 - 419
  • [46] Tonometer validation and intraocular pressure reference values in the normal chinchilla (Chinchilla lanigera)
    Snyder, Kevin C.
    Lewin, Andrew C.
    Mans, Christoph
    McLellan, Gillian J.
    VETERINARY OPHTHALMOLOGY, 2018, 21 (01) : 4 - 9
  • [47] Reference Values of the Central Corneal Thickness with Different Refractive Errors for the Adult Egyptian Population
    Gab-Alla, Amr A.
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 3465 - 3474
  • [48] Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group
    Min Chen
    Lina Zhang
    Jia Xu
    Xinyi Chen
    Yuxiang Gu
    Yuping Ren
    Kaijun Wang
    BMC Ophthalmology, 19
  • [49] Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group
    Chen, Min
    Zhang, Lina
    Xu, Jia
    Chen, Xinyi
    Gu, Yuxiang
    Ren, Yuping
    Wang, Kaijun
    BMC OPHTHALMOLOGY, 2019, 19 (01)
  • [50] Reference values for intraocular pressure and Schirmer tear test in clinically normal Sanjabi sheep
    Ghaffari, Masoud Selk
    Shojaei, Mohammad
    Sabzevari, Amin
    Khorami, Nargess
    SMALL RUMINANT RESEARCH, 2011, 97 (1-3) : 101 - 103