Feasibility of optimal vertex size and spacing for lattice radiotherapy implementation using helical tomotherapy

被引:0
作者
Seol, Yunji [1 ]
Lee, Young Kyu [1 ]
Kim, Byeong Jin [1 ]
Choi, Kyu Hye [1 ]
Hong, Ji Hyun [1 ]
Park, Chan-beom [2 ]
Kim, Sun Hwa [2 ]
Park, Hyeong Wook [3 ]
Kim, Jung-Il [4 ]
Cheon, Wonjoong [1 ]
Kang, Young-nam [1 ]
Choi, Byung Ock [1 ]
机构
[1] Catholic Univ, Seoul St Marys Hosp, Coll Med, Dept Radiat Oncol, Seoul, South Korea
[2] Catholic Univ Korea, Dept Biomed & Hlth Sci, Seoul, South Korea
[3] Kyonggi Univ, Dept Med Phys, Suwon, South Korea
[4] Korea Electrotechnol Res Inst, Electromed Device Res Ctr, Ansan, South Korea
来源
FRONTIERS IN ONCOLOGY | 2025年 / 15卷
关键词
lattice radiotherapy; spatially fractionated radiotherapy; helical tomotherapy; vertex; valley-to-peak dose ratio; FRACTIONATED RADIATION-THERAPY; LUNG-CANCER;
D O I
10.3389/fonc.2025.1512064
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose Lattice radiotherapy (LRT), a type of spatially fractionated radiotherapy (SFRT), delivers high dose at specific volumes of lattice structure within the tumor to create a low valley-to-peak dose ratio (VPDR). This study aims to evaluate the feasibility of implementing SFRT using helical tomotherapy and to investigate the effects of vertex size and spacing for attaining the VPDR.Methods A three-dimensional lattice structure with 3x3x3 vertices was designed in a cheese phantom. Vertex sizes of 0.5 cm, 1.0 cm, and 2.0 cm were assessed, with spacing from 1.0 cm to 5.0 cm. The prescribed dose was set to 20 Gy to the vertices in a single fraction. VPDR was calculated from dose profiles along lines connecting three vertices in the anterior-posterior (AP), lateral (LAT), and superior-inferior (SI) directions. The minimum, maximum, and mean dose for each vertex, as well as conformity, homogeneity and monitor unit (MU) analysis were also performed.Results VPDR decreased significantly with increasing vertex size and spacing. While the AP and LAT directions showed similar VPDR values, the SI direction consistently exhibited lower VPDR values across all configurations. Vertex sizes of 0.5 cm, 1.0 cm, and 2.0 cm required spacing of at least 3.0 cm, 2.0 cm, and 1.0 cm, respectively, to achieve VPDR values below 0.4. The conformity indices ranged from 1.0 to 4.02, and the homogeneity indices ranged from 1.20 to 1.57 across all configurations. Additionally, the MUs increased with both vertex size and spacing.Conclusions This study quantitatively analyzed the impact of various vertex sizes and spacings on VPDR in lattice radiotherapy using helical tomotherapy. VPDR decreased with increasing vertex size and spacing, with consistently lower values in the SI direction. These findings provide crucial insights for optimizing LRT plans. The identified relationships between the parameters and VPDR offer a foundation for developing more effective LRT protocols in helical tomotherapy, potentially improving therapeutic outcomes
引用
收藏
页数:10
相关论文
共 36 条
  • [21] Comparison of Effects Between Central and Peripheral Stage I Lung Cancer Using Image-Guided Stereotactic Body Radiotherapy via Helical Tomotherapy
    He, Jian
    Huang, Yan
    Shi, Shiming
    Hu, Yong
    Zeng, Zhaochong
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (06) : 701 - 707
  • [22] Semi-automated vertex placement for lattice radiotherapy and dosimetric verification using 3D polymer gel dosimetry
    Kunkyab, Tenzin
    Magliari, Anthony
    Jirasek, Andrew
    Mou, Benjamin
    Hyde, Derek
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (11):
  • [23] High-dose Radiotherapy Using Helical Tomotherapy for Vertebral Metastasis: Early Clinical Outcomes and Cord Dose Specification
    Lee, Dong Soo
    Kwak, Yoo Kang
    Jeong, Song Mi
    Song, Jin Ho
    Kang, Young Nam
    Lee, Sang Nam
    Jang, Hong Seok
    Kim, Yeon Sil
    Yoon, Sei Chul
    Choi, Byung Ock
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2013, 43 (06) : 646 - 653
  • [24] Implementation of HybridArc treatment technique in preoperative radiotherapy of rectal cancer: dose patterns in target lesions and organs at risk as compared to helical Tomotherapy and RapidArc
    Thierry Gevaert
    Benedikt Engels
    Cristina Garibaldi
    Dirk Verellen
    Peter Deconinck
    Michael Duchateau
    Truus Reynders
    Koen Tournel
    Mark De Ridder
    Radiation Oncology, 7
  • [25] Implementation of HybridArc treatment technique in preoperative radiotherapy of rectal cancer: dose patterns in target lesions and organs at risk as compared to helical Tomotherapy and RapidArc
    Gevaert, Thierry
    Engels, Benedikt
    Garibaldi, Cristina
    Verellen, Dirk
    Deconinck, Peter
    Duchateau, Michael
    Reynders, Truus
    Tournel, Koen
    De Ridder, Mark
    RADIATION ONCOLOGY, 2012, 7
  • [26] HIPPOCAMPAL-SPARING WHOLE-BRAIN RADIOTHERAPY: A "HOW-TO" TECHNIQUE USING HELICAL TOMOTHERAPY AND LINEAR ACCELERATOR-BASED INTENSITY-MODULATED RADIOTHERAPY
    Gondi, Vinai
    Tolakanahalli, Ranjini
    Mehta, Minesh P.
    Tewatia, Dinesh
    Rowley, Howard
    Kuo, John S.
    Khuntia, Deepak
    Tome, Wolfgang A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (04): : 1244 - 1252
  • [27] Feasibility of lattice radiotherapy using proton and carbon-ion pencil beam for sinonasal malignancy
    Yang, Dong
    Wang, Weiwei
    Hu, Jiyi
    Hu, Weixu
    Zhang, Xiyu
    Wu, Xiaodong
    Lu, Jiade J.
    Kong, Lin
    ANNALS OF TRANSLATIONAL MEDICINE, 2022, 10 (08)
  • [28] Successful salvage treatment of myxoid liposarcoma with multiple peritoneal seeding using helical tomotherapy-based intraperitoneal radiotherapy: A case report
    Choi C.
    Park J.H.
    Lee C.G.
    Kim H.J.
    Suh C.-O.
    Cho J.
    BMC Research Notes, 8 (1)
  • [29] Re-irradiation of unresectable recurrent head and neck cancer: using Helical Tomotherapy as image-guided intensity-modulated radiotherapy
    Jeong, Songmi
    Yoo, Eun Jung
    Kim, Ji Yoon
    Han, Chi Wha
    Kim, Ki Jun
    Kay, Chul Seung
    RADIATION ONCOLOGY JOURNAL, 2013, 31 (04): : 206 - 215
  • [30] Comparison of the 3D-conformal, helical tomotherapy and multileaf collimators-based intensity modulated radiotherapy modalities using radiobiological measures
    Mavroidis, P.
    Ferreira, B. Costa
    Shi, C.
    Lind, B. K.
    Papanikolaou, N.
    JOURNAL OF BUON, 2008, 13 (01): : 75 - 86